26 28.5 33.5 M18 x 1.5 -X (mm) Without auto switch With auto switch A B A B 20U Z Bore size (mm) Stroke range (mm) C D E F H I J K L M N O P Q S 5 to 50 40 33 Data 9 depth 7 32 50 43 13 16 45 7.5 M8 x 1.25 60 4.5 14 7 34 5.5 1/8 10.5 58.5 31.5 14 75, 100 50 43 5 to 50 46.5 39.5 9 depth 7 40 56.5 49.5 13 16 52 8 M8 x 1.25 69 5 14 7 40 5.5 1/8 11 66 35 14 75, 100 56.5 49.5 10 to 50 48.5 40.5
mA PNP open collector Max. 30 VDC, 50 mA NPN open collector Max. 30 VDC, 50 mA PNP open collector Max. 30 VDC, 50 mA RS Q G Output transistor mode 80 to 120 VAC 50/60 Hz 21.6 to 26.4 VDC Power supply voltage RS H A 10 VA or less 5 W or less Power consumption RZQ Between case and AC line: 1500 VAC for 1 min.
mA PNP open collector Max. 30 VDC, 50 mA NPN open collector Max. 30 VDC, 50 mA PNP open collector Max. 30 VDC, 50 mA RS Q G Output transistor mode 80 to 120 VAC 50/60 Hz 21.6 to 26.4 VDC Power supply voltage RS H A 10 VA or less 5 W or less Power consumption RZQ Between case and AC line: 1500 VAC for 1 min.
A Graph 1 Graph 2 120 60 110 B 100 50 C P1 63 63 90 80 40 70 Regulator Circuit C Load weight (kg) Load weight (kg) P2 60 30 50 50 A 50 Regulator valve 40 20 40 40 30 B 32 32 20 10 C P1 10 0 0 0.4 0.3 0.3 0.5 0.6 0.7 Operating pressure (MPa) 0.4 0.5 0.6 0.7 Operating pressure (MPa) Selection example Confirmation of allowable kinetic energy Selection conditions: Transfer direction: Vertical
(mm) U U U U U U U U U U 32 31.5 32.5 38.5 35 38 34 27 29 26.5 40 35 36 42 38.5 44 41.5 37.5 30.5 32.5 30 50 41 42 48 44.5 47.5 50 43.5 36.5 38.5 36 63 47.5 48.5 54.5 51 54 50 56.5 40 42 39.5 12 Series RZQ Auto Switch Mounting Follow the procedures below to mount auto switches.
Series CQ2 Compact Cylinder: Long Stroke Type Double Acting, Single Rod 32, 40, 50, 63, 80, 100. How to Order . Precautions. Specifications. Construction. Dimensions . Series RQ Compact Cylinder with Air Cushion 20, 25, 32, 40, 50, 63, 80, 100. Features. Series Variations. Series RQ Compact Cylinder with Air Cushion Double Acting, Single Rod 20, 25, 32, 40, 50, 63, 80, 100 .
Size 25 32 40 50 l 18.2 22.2 26.2 32.2 Size 25 32 40 50 Part no.
DATA OUT 1 2 3 SET 1 2 SET MONOSASHI-KUN AC100V OUT1 COM OUT2 COM COM OUT3 Series Guide Series CE1 Bore size (mm) Available stroke range Standard stroke (mm) Series CEP1 Standard stroke (mm) Bore size (mm) 12 equiv. 250 400 500 300 175 200 150 125 100 75 50 100 25 75 50 25 12 25 to 150 20 equiv. 20 25 to 300 32 25 to 400 40 25 to 600 50 25 to 600 63 25 to 600 CEU1 CEU5 Output transistor system
Series CBQ2 Allowable Kinetic Energy Allowable Rod End Lateral Load 0.5MPa 0.4MPa With rubber bumper With auto switch (lateral resistance) 200 100 100 50 50 40 30 Allowable lateral load W (N) 63 20 Load weight kg 50 10 63 40 32 10 5 4 3 50 5 2 40 1 0 10 20 30 40 50 60 70 80 90 100 32 Stroke St (mm) 1 50 100 200 500 300 Maximum speed mm/s (Mounting orientation: Horizontal) W
Switch spacer Switch mounting nut 32 40 50 63 40 V V V V V V V V V 50 BQ-2 V V V 63 V V V Contact SMC regarding non-standard strokes.
5 to 50 46.5 39.5 9 depth 7 40 56.5 49.5 13 16 52 8 M8 x 1.25 69 5 14 7 40 5.5 1/8 11 66 35 14 75, 100 56.5 49.5 10 to 50 48.5 40.5 11 depth 8 50 58.5 50.5 15 20 64 10.5 M10 x 1.5 86 7 17 8 50 6.6 1/4 10.5 80 41 19 75, 100 58.5 50.5 6 Series CQ2Y Mounting bracket dimensions are the same as those of the anti-lateral load type of Series CQ2S.
Linear Motion/Standard Motion Size Standard stroke (mm) 32/40 5, 10, 15, 20, 25, 30, 40, 50, 75, 100 Refer to p.1.5-18 for other intermediate strokes.
Standard strokes (mm) Bore sizes (mm) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 32, 40 50, 63 80, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Example) For CQ2XB40-57D, an 18mm spacer is installed inside a standard stroke CQ2XB40-75D cylinder. Specific Product Precautions Be sure to read before handling. Refer to pages 15 to 24 for safety instructions and precautions.
D-A72(H) must be used with the contact protection box regardless of load types and lead wire length since it is greatly affected by loads.
15 + 40(n 2) 2 (n = 2, 4, 6) Note 3) 50 + 20 (n 2) (n = 2, 3, 4, 5) D-H7m/H7mW D-H7BA D-H7NF 10 15 60 15 + 45(n 2) 2 (n = 2, 4, 6) Note 3) 60 + 22.5 (n 2) (n = 2, 3, 4, 5) D-C73C D-C80C D-H7C 10 15 65 15 + 50(n 2) 2 (n = 2, 4, 6) Note 3) 50 + 27.5 (n 2) (n = 2, 3, 4, 5) D-M9mV 5 5 10 + 10 (n 2) (n = 4, 6) Note 4) D-A9mV 5 10 10 + 15 (n 2) (n = 4, 6) Note 4) D-M9m D-A9m 10
Bore size 32 mm 32 40 mm 40 50 mm 50 63 mm 63 Action Double acting D Applicable Auto Switch/Refer to page 12-13-1 for further information on auto switches.
Bore size 32 mm 32 40 mm 40 50 mm 50 63 mm 63 Action Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Double acting D Applicable Auto Switch/Refer to page 12-13-1 for further information on auto switches.
Standard Stroke Bore size (mm) Standard stroke (mm) Maximum available stroke (mm) Made to Order: Individual Specifications (For details, refer to pages 1538 and 1539.) 6 10 300 500 50, 100, 150, 200 50, 100, 150, 200, 250, 300 50, 100, 150, 200, 250, 300, 350 400, 450, 500 Symbol Specifications -X116 -X168 -X322 -X431 Hydro specifications 15 750 Helical insert thread specifications 20 25
Cylinder bore 32 mm 40 mm 50 mm 63 mm Auto switch is attachable. 32 40 50 63 Action Double acting D Auto Switch Specifications / Refer to p.2.11-1 for further information of auto switch.