MHC2-10D JIS Symbol Double acting How to Order D 20 MHC2 Y59A S Number of auto switches Single acting Angular style air gripper 2 pcs. 1 pc. S Nil Bore size 10 mm 10 Action Auto switch Single acting S 16 mm 16 20 mm 20 25 mm 25 Double acting D Nil Without auto switch (Built-in magnet) For the applicable auto switch model, refer to the table below.
10 18.5 71.6 9.8 47.3 21 AS2051F-09D 5/16" 15.2 59.8 8.1 36.7 18 AS3001F-12D 12 20.9 76 11 48.5 22 AS3001F-07D 1/4" 13.2 59 7.4 45.2 17 AS4001F-10D 10 18.5 55.4 21 AS3001F-09D 5/16" 19.8 9.8 1.2 15.2 64.4 8.2 46 18 26.5 12.4 82 11.3 1.2 AS4001F-12D 12 20.9 56.4 22 AS3001F-11D 3/8" 17.9 70.8 9.5 47.2 21 AS4001F-11D 3/8" 17.9 76.9 10.3 55.5 21 26.5 12.4 1.2 AS4001F-13D 1/2" 21.7 83.1 11.6
Model Bore size mm Holding moment (effective value) (1) Opening/closing angle (both sides) Weight (2) Action Model g 39 91 180 311 10 16 20 25 0.10 0.39 0.70 1.36 MHC2-10D MHC2-16D MHC2-20D MHC2-25D 30 to 10 Double acting 0.070 0.31 0.54 1.08 10 16 20 25 39 92 183 316 MHC2-10S MHC2-16S MHC2-20S MHC2-25S MHC2-16S 30 to 10 Single acting MHC2-10D Note1) At pressure 0.5MPa.
(Series AS-FM/AS-M) 5 to 50mm/s Piston speed Air cushion Cushion Available for mounting Auto switch Basic, Foot, Flange, Clevis, Trunnion Mounting 6-17-35 30 Made to Order Common Specifications: -XB14: Cylinder with Heat Resistant Auto Switch Symbol -XB14 9 Cylinder with Heat Resistant Auto Switch Heat resistant compact cylinder Series CDQ2 (16 to 63) which can mount heat resistant solid
40 50 63 CDQ2 Compact cylinder CDQ2-XB14 Double acting, Single rod Except with rubber bumper Series D-M9 J 15-E644 Symbol -XB14 Cylinder with Heat Resistant Auto Switch / Series CQ2 1 How to Order CDQ2 D Z M9NJL XB14 With auto switch Mounting Number of auto switches Type Bore size (See Table 1.)
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 20mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 32mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 50mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number
(Or None in the Case of No Switch), Environmental Options: XB14 (w/Heat Resistant Auto Switch)
(Or None in the Case of No Switch), Environmental Options: XB14 (w/Heat Resistant Auto Switch)
(Or None in the Case of No Switch), Environmental Options: XB14 (w/Heat Resistant Auto Switch)
(Or None in the Case of No Switch), Environmental Options: XB14 (w/Heat Resistant Auto Switch)
switch option (XB14) temperature range 0°F to 302°F
switch option (XB14) temperature range 0°F to 302°F
Yes, it is available using the special order part number suffix “-XB14.” The product is a combination of a heat-resistant CDQ2 series cylinder (bore sizes ø16 to ø63) and a heat-resistant auto switch for the CDQ2.
The “-XB14” uses an “-XB6” heat-resistant cylinder (with heat-resistant seal material and grease) with a built-in heat-resistant magnet (for CDQ2 series cylinders).
40 50 63 CDQ2 Compact cylinder CDQ2-XB14 Double acting, Single rod Except with rubber bumper Series D-M9 J 15-E644
SMC solves these limitations with our XB14 option, the markets original compact cylinder with the D-F7NJ heat resistant switch. Special seals and heat resistant grease allow this product to be placed on designs located in environments up to 300F, making high temperature environments no longer a restriction.
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Single acting, single rod, compact cylinder , Bore sizes *: 12, 16, 20, 25