Weight/( ): Denotes the values with D-A93. (g) Bore size (mm) Hexagon socket head cap screw dia.
Tie-rod mount Reed switches 2 color indication With timer 2 color indication 2 color indication/water resistant 2 color indication/with diagnostic output Direct mount D-A93 D-G39/K39 D-F5/J5 D-F5NTL D-F5W/J59W D-F5BAL D-F5F D-F9N Band mount Tie-rod mount Solid state switches D-F9P Direct mount D-F9B Models D-A90, D-A93, D-F9N, D-F9P and D-F9B are exclusively for use with the lock unit
100 105 110 D-Y7BA n 85 + 45 (n 4) 2 (n = 4, 8, 12, 16)*2 90 + 45 (n 4) 2 (n = 4, 8, 12, 16)*2 100 + 45 (n 4) 2 (n = 4, 8, 12, 16)*2 105 + 45 (n 4) 2 (n = 4, 8, 12, 16)*2 110 + 45 (n 4) 2 (n = 4, 8, 12, 16)*2 2 (Different surfaces, same surface) 1 90 95 100 105 110 D-P3DWA n (Different surfaces, same surface) 90 + 50 (n 4) 2 (n = 4, 8, 12, 16)*2 95 + 50 (n 4) 2 (n = 4, 8, 12, 16)*
S A 3H9 effective depth 2 3H9 effective depth 2 TD TB TC D (g6) DD (h9) Rotation A AU B BA BB BC BD BU H Size 42 (8.5) 29 8.5 17 53 (9.5) 31 9 26.4 6.7 10.6 2.2 16.7 23.1 18 20 12 14 5 6 10 15 90, 180 90, 180 W Q S US UW ab M TC TD TA Size Rotation 4.5 17 56 69 65 82 90 180 90 180 10 35 44 6 9 8 15.4 15.5 15 5.5 20 40 50 7 10 9 17.6 16 Dimension AU does not indicate the dimension when shipped
Mounting bolt Mounting bolt D 35 40 45 50 55 60 35 40 45 50 55 60 45 50 55 60 Model C Model C D 65 70 75 80 85 90 45 50 55 60 65 70 75 80 85 90 CDQSWB12-5D -10D -15D -20D -25D -30D CDQSWB16-5D -10D -15D -20D -25D -30D CDQSWB20-5D -10D -15D -20D CDQSWB20-25D -30D -35D -40D -45D -50D CDQSWB25-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D M3 x 35l x 40l x 45l x 50l x 55l x 60l M3 x 35l x 40l
38 73 16.5 25.5 90 87 115 10 11 M6 x 1.0 M14 x 1.5 Rc(PT)1/8 7 40 70 100 42 73 16.5 25.5 0.5 1 90 97 115 12 11.5 M8 x 1.25 M20 x 1.5 Rc(PT)1/8 8.7 40 75 122 50 91 18.5 28.5 0.5 1 110 119 138 12 10.5 M8 x 1.25 M20 x 1.5 Rc(PT)1/4 8.7 65 105 145 64 99 20.5 35.5 1 1 120 142 155 PA dimensions are for split from center.
Valve opening The time from the application of voltage to the actuation solenoid valve until 90% of the valve stroke has been completed is the valve opening response time. Valve opening operation time indicates the time from the start of the stroke until 90% of movement has been completed. Both of these become faster as the operating pressure is increased.
Valve closing The time from the cut off of power to the actuation solenoid valve until 90% of the valve return stroke has been completed is the valve closing response time. Valve closing operation time indicates the time from valve opening until 90% of return movement has been completed.
Contact protection box OUT() Brown [Red] Reed switch CD-P11 OUT( ) Blue [Black] Weights CD-P12 (g) D-A93(V) Brown [Red] D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V LED Auto switch part no.
D-A90(V) OUT() Brown Contact protection box CD-P11 CD-P12 Reed switch OUT() Blue Weight (g) D-A93(V) Model D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V LED Brown OUT (+) Brown 41 Lead wire length (m) 0.5 6 6 6 6 8 8 Contact protection box CD-P11 CD-P12 Resistor 3 30 30 30 30 41 Reed switch Zener diode Dimensions (mm) OUT () Blue Blue D-A90/D-A93/D-A96 2 2.8 4.5 2.7 D-A96(V) DC (+) Brown 4 LED
Rotate about 90 o from when you feel the fitting. Set screw(Attached to the auto switch) Auto switch Watch maker's screwdriver 73
Rotate about 90 from when you feel the fitting tightness. Watch maker's screwdriver MGF Auto switch CY1 MY1 3.11-35 World Wide QS\E Support... North American Branch Offices For a branch office near you call: 1-800-SMC-SMC1 (762-7621) SMC Pneumatics lnc. (Milwaukee) SMC Pneumatics lnc. (Richmond) SMC Pneumatics Inc.
90 38 73 16.5 25.5 87 115 REAS25 Rc 1/8 40 70 100 90 42 73 16.5 25.5 0.5 1 97 115 REAS32 Rc 1/8 40 75 122 110 50 91 18.5 28.5 0.5 1 119 138 REAS40 Rc 1/4 65 105 145 120 64 99 20.5 35.5 1 1 142 155 PA dimensions are for split from center. 10-2-34 34 Sine Rodless Cylinder Slider Type: Slide Bearing Series REAS Proper Auto Switch Mounting Position (Detection at stroke end) RE A B B A REC
90 38 73 16.5 25.5 87 115 REAS25 Rc 1/8 40 70 100 90 42 73 16.5 25.5 0.5 1 97 115 REAS32 Rc 1/8 40 75 122 110 50 91 18.5 28.5 0.5 1 119 138 REAS40 Rc 1/4 65 105 145 120 64 99 20.5 35.5 1 1 142 155 PA dimensions are for split from center. 10-2-34 34 Sine Rodless Cylinder Slider Type: Slide Bearing Series REAS Proper Auto Switch Mounting Position (Detection at stroke end) RE A B B A REC
Consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Solid state auto switches marked are produced upon receipt of order.
20 10 145 52 28 28 12 15 12 160 75 68 45 45 12 5.5 10 170 175 45 90 9 70 110 25 12 155 60 32 32 12 15 12 170 80 80 50 50 12 5.5 10 185 190 50 100 9 80 120 25 12 170 70 40 40 16 20 16 190 90 100 63 63 14 6.5 12 210 215 63 126 12 100 153 30 16 190 90 50 50 16 20 16 210 110 120 75 71 16 6.5 14.5 220 230 75 150 14 120 178 35 16 205 110 60 60 20 25 20 230 140 Max. 157 90 90 Max. 25 8 16 250 270
to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC Power consumption 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less Between case and AC line: 1500 VAC for 1 min.
As a guide, it should be turned about 90 past the point at which tightening can be felt. 9-9-23