SMC Corporation of America
Elite Part Number Search
Search Results "CE1F40-400-M9BW"

10 High precision type CRJ MSZB A M9BW 10 Basic type CRA1 Number of auto switches CRQ2 Nil n 2 pcs. n pcs.

[mm] Bore size MXZ MXH MGP CQM 12 37.4 471 58 25 16 40.9 53.5 64 29 20 49.4 64.5 83 36 25 57.4 93 40 Compact auto switch can be mounted directly. 1 Compared with bore size of 10 Mounting Through-hole mounting Tap mounting 1 Compact Cylinder with Linear Guide MXZ Series Port Location Selectable Auto Switch Mountable on 3 Surfaces (For 20, 25) Solid state auto switch: D-M9 MXZ20 -30-M9BW

. :0.1 D 50 : : mmax 1 RS2H mmax : mmax (Kg) =0.1 =0.2 NO 50 400 280 mAm max 63 530 365 YES 80 800 565 V m mmax=0.1 200<400 mP6 -1-* -1-1V=20m/minm=278(Kg) 200278 NO mA m YES FA=mAg FA 2000.19.8 196(N) FAmAg(N) (g: :9.8m/S 2) P F -2-1P=0.5(MPaF=766(N)766(N) 196776 P7 -2-1 NO FA F RS2H50 YES v [m/min] m [kg] -1 5 - -1-1.(RS2H50) -1-2.(RS2H63 -1-3.

Lead wire length (m) Auto switch model Electrical entry direction Load voltage Pre-wired connector Applicable load 5 (Z) Type Electrical entry Special function Indicator light Wiring (Output) 0.5 (Nil) 1 (M) 3 (L) DC AC Perpendicular In-line M9NV M9PV M9BV M9NWV M9PWV M9BWV M9N M9P M9B M9NW M9PW M9BW M9NA 3-wire(NPN) IC circuit 5 V, 12 V Solid state auto switch 12 V 3-wire(PNP) 2-wire 3

In Graph 0, find the intersection of a 30 mm overhang L and load mass m of 0.1 kg, which results in a determination of 10. 18 Compact Slide 6, 10, 16, 20 MXH Series RoHS MXH MXH How to Order MXS MXQ MXH Z 10 M9BW 60 MXQ MXF Made to Order Refer to page 20 for details. Compact Slide MXW Bore size Number of auto switches MXJ 6 10 16 20 6 mm 10 mm 16 mm 20 mm Nil S 2 pcs. 1 pc.

CJ2-Z Series 10, 16 Air Cylinder 10-/1121-/22RoHS How to Order Cushion Clean series 10 11 Relief type Vacuum suction type Rubber bumper (Standard) Air cushion Nil A 10 D L 16 60 A R C J 2 M9BW Z B 21 D L 16 60 R C J 2 M9BW Z B Number of auto switches Nil Built-in magnet Head cover port location 2 pcs. 1 pc. n pcs.

: Built-in magnet, Port thread type: Rc, Auto Switches: M9BW, Lead Wire Length(m): 5, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Mount Support: Basic type, Rod Boot: None, Custom-made Specifications: None, Locking Direction: Bidirectional

: Built-in magnet, Port thread type: Rc, Auto Switches: M9BW, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Mount Support: Axial foot type, Rod Boot: None, Custom-made Specifications: None, Locking Direction: Bidirectional

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: NPT, Auto Switches: M9BW, Lead Wire Length(m): 3, The number of the switches: 2, Type of

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: M9BW, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of