AS-25L ZH13/15DA Applicable thread size: M4 AS-30L ZH18/20DA Applicable thread size: M4 L-bracket wDIN Rail Mounting Bracket1 Part no. Applicable model Note Quantity AS-10D ZH05/07/10DA Applicable thread size: M3 1 pc. AS-25D ZH13/15DA Applicable thread size: M4 AS-30D ZH18/20DA Applicable thread size: M4 1 DIN rail is not included. It should be provided by the customer.
9 45 18 38 10 65 150 3 x 16l 32 9 45 38 18 10 65 152 4 x 24l 40 12 50 38 55 13 83 200 Series CA2 (CBA2, CV3, CVS1) Hole: NDH10 Shaft: NDd9 Spring pin ZZ + Stroke H10 d9 NZ ND L1 RR1 H ZZ PY PX NX Bore size (mm) Spring pin +0.070 0 +0.070 0 +0.070 0 +0.070 0 +0.084 0 0.050 0.093 0.050 0.093 0.050 0.093 0.050 0.093 0.065 0.117 +0.3 +0.1 16 4 x 24l 40 12 13 51 192 84 11 38 55 +0.3 +0.1 4 x 25l
D2) Screw a manual unlocking bolt (a conventional bolt of 25, 32: M3 x 0.5 x 25l or more, 40, 50: M4 x 0.7 x 35l or more) into the lock ring threads as shown above, and lightly push the bolt in the direction of the arrow (rod side) to unlock. 2) Screw a manual unlocking bolt (a conventional bolt of 25, 32: M3 x 0.5 x 25l or more, 40, 50: M4 x 0.7 x 35l or more) into the lock ring threads
Applicable series AS-12L AS-10L AS-20L AS-25L AS-30L AS-40L AS-10D AS-20D AS-25D AS-30D AS-40D AS1002F-02 AS1002F AS2002F AS2052F AS3002F AS4002F AS1002F AS2002F AS2052F AS3002F AS4002F DIN rail mounting bracket L-bracket Prepare DIN rail by user. Bracket for AS1002F-02 is not available.
Applicable model AS-10L AS1002Fm AS-20L AS2002Fm AS-25L AS2052Fm AS-30L AS3002Fm AS-40L AS4002Fm Part no.
MHQ MHL2 MHC2-25l MHR MHK MHS MHC2 MHT2 MHY2 MHW2 MRHQ Auto switch Note) When signal acting type is used, one side port is bleed port and adjusting needle for finger speed is not attached. When auto switch is used, through hole mounting type is not available.
/Symmetric Type 114 Air Slide Table Series MXQ Dimensions MXQ 25L/Symmetric Type 115 Series MXQ Air Slide Table Auto Switch/Proper Mounting Position at Detection of Stroke End 116 Air Slide Table Series MXQ Made To Order 117
Avoid applications in which two or more end lock cylinders are synchronized to move one workpiece, as one of the cylinder locks may not be able to release when required. 4.9N 2 20, 25, 32 M2.5 x 0.45 x 25L or more M3 x 0.5 x 30L or more 40 10N 3 6. Use a speed controller with meter-out control. Lock cannot be released occasionally by meter-in control.
The standard lead wire length IS 06m.Grommet L IS added for 3m long lead wire (Example) ZSE4B-Ol -25L Port size: 01 stands for R(PT)1/8 and TI tor NPTF1 /8 Both types have M5X0.8 female threads InSide, Option (Available separately) Panel mount adaptor No.
Example) Bolt M3 X 25l 4pcs. Calculation Example: CQ2D32-20DCM Cylinder weight: CQ2B32-20D Option weight: Both ends tapped Rod end male thread With rubber bumper Double clevis 193g 6g 43g 3g 151g 390g CQS CQ2 MU D 30 35 40 45 50 55 60 65 70 75 110 135 35 40 45 50 55 60 65 70 75 80 115 140 45 50 55 60 65 70 75 80 85 120 145 Model No. C Mounting bolt Model No. Mounting bolt Model No.
Bore size (mm) Bolt Tightening torque (Nm) Width across flats 125 M12 x 1.75 x 25l 10 30.1 160, 200 M16 x 2 x 30l 14 99 M20 x 2.5 x 35l 17 193.5 250 Foot Others M20 x 2.5 x 30l 17 6-12-42
D-X 20Data Stroke (mm) Bore size (mm) Thread size Pulling force 16 2 4.9 M2.5 x 0.45 x 25l or more Bolt should be detached under normal operation, otherwise it may cause malfunction of the locking feature. Rubber cap 6-3-83
(Drill through) Note) Dd9 L l d m H B C CJ1 D Cotter pin 3 x 18l 4 x 25l 4 x 35l 0.040 0.076 0.050 0.093 0.065 0.117 NT-03 NT-04 NT-05 NT-08 NT-10 CD-M03 CD-M05 CD-M08 10 14 22 32 40 50, 63 80 100 32, 40 50, 63 80, 100 3 4 4 44 60 82 36 51 72 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 4 4.5 5 6 8 11 13 16 17 22 27 32 41 19.6 25.4 31.2 37.0 47.3 16.5 21 26 31 39 CJP CJ2 Note) When
www.stevenengineering.com Without Auto Switch For Axial Mounting For Lateral Mounting B 21 23 25 27 22 24 26 28 33 22 24 26 28 33 38 22 24 26 28 33 38 Model Mounting bolt CUJB4-4 -6 -8 -10 CUJB6-4 -6 -8 -10 -15 CUJB8-4 -6 -8 -10 -15 -20 CUJB10-4 -6 -8 -10 -15 -20 Model Mounting bolt CUJB4-4 -6 -8 -10 CUJB6-4 -6 -8 -10 -15 CUJB8-4 -6 -8 -10 -15 -20 CUJB10-4 -6 -8 -10 -15 -20 C D A M2.5 x 21l M2.5 x 23l M2.5 x 25l
M2.5 x 0.45 x 25l or more 20, 25, 32 4.9 N 2 M3 x 0.5 x 30l or more 40, 50, 63 10 N 3 M5 x 0.8 x 40l or more 80, 100 24.5 N 3 5. Do not operate multiple cylinders in synchronization. Avoid applications in which two or more end lock cylinders are synchronized to move one workpiece, as one of the cylinder locks may not be able to release when required.
Bore size (mm) Part no. m d (Drill through) Cotter pin Note) l d Dd9 L H B C D CNG 3 x 18l 4 x 25l 4 x 35l Note) A cotter pin should be used together with a plain washer. 6 8 11 13 16 4 4.5 5 3 4 4 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 16.5 21 26 31 39 0.040 0.076 0.050 0.093 0.065 0.117 CD-M03 CD-M05 CD-M08 NT-03 NT-04 NT-05 NT-08 NT-10 32, 40 50, 63 80, 100 10 14 22 32 40 50
28 42 56.4 (DC24V) A/B 800 / [V] DC2410% [W] 8) 23 40 50 [W] 9) 16 15 48 [W] 10) 43 48 104 11) [N] 20 39 78 78 157 294 108 216 421 [W] 12) 3.6 5 5 [V] DC2410% LEYG 16M _ LEYG 25M _ LEYG 32M _ [mm] 30 50 100 150 200 30 50 100 150 200 250 300 30 50 100 150 200 250 300 (kg) 0.83 0.97 1.20 1.49 1.66 1.67 1.86 2.18 2.60 2.94 3.28 3.54 2.91 3.17 3.72 4.28 4.95 5.44 5.88 LEYG 16L _ LEYG 25L
40%) INP 1) INP ON 0.50 2) ()INP ON a) b) INP ON c) INP ON 21 - INP SV1.0* () INP ON SV0.6* a.40%() () INP ON b. 40% ON INP OFF LEHZ LEHZJ LEHF LEHS SV10 [mm/sec] () 4150 50% 100% 540 40% 100% 3150 70% 100% 2130 50% 100% 520 40% 100% [mm/sec] () 4150 50% 100% 10 , 16 20 , 25 540 40% 100% 2150 80% 100% 1120 60% 100% 10L , 16L 510 50% 100% 3150 70% 100% 20L , 25L
(Drill through) Note) Dd9 L l d m H B C CJ1 D Cotter pin 3 x 18l 4 x 25l 4 x 35l 0.040 0.076 0.050 0.093 0.065 0.117 NT-03 NT-04 NT-05 NT-08 NT-10 CD-M03 CD-M05 CD-M08 10 14 22 32 40 50, 63 80 100 32, 40 50, 63 80, 100 3 4 4 44 60 82 36 51 72 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 4 4.5 5 6 8 11 13 16 17 22 27 32 41 19.6 25.4 31.2 37.0 47.3 16.5 21 26 31 39 CJP CJ2 Note) When
Bore size (mm) Part no. m d (Drill through) Cotter pin Note) l d Dd9 L H B C D CNG 3 x 18l 4 x 25l 4 x 35l Note) A cotter pin should be used together with a plain washer. 6 8 11 13 16 4 4.5 5 3 4 4 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 16.5 21 26 31 39 0.040 0.076 0.050 0.093 0.065 0.117 CD-M03 CD-M05 CD-M08 NT-03 NT-04 NT-05 NT-08 NT-10 32, 40 50, 63 80, 100 10 14 22 32 40 50