SMC Corporation of America
Elite Part Number Search
Search Results "CLSL200TN-1400"

Applicable strokes: 250, 350, 450, 550, 650, 700, 750, 850, 900, 950, 1050, 1100, 1150, 1250, 1300, 1350, 1400, 1450 Example) LJ1H3031PD-250-F2-X2 Allowable Moment (Nm) Allowable static moment Allowable dynamic moment Pitching Rolling Yawing Mounting orientation Load movement direction 117 137 123 Model LJ1H30 Horizontal/Lateral Horizontal/Lateral Lateral Horizontal a Mep a = 1000 2000 L1

3000 mm/s2 2 Work load: W [kg] Work load: W [kg] 3000 mm/s2 1.5 1 0.5 5000 mm/s2 10 mm/s2 0 1400 200 400 600 800 1000 1200 0 Speed: V [mm/s] Speed: V [mm/s] EQFS25HA/Ball Screw Drive Horizontal/Lead 12 Vertical/Lead 12 35 9 8 7 6 5 4 3 2 1 0 3000 mm/s2 30 Work load: W [kg] Work load: W [kg] 3000 mm/s2 25 20 15 10 10 mm/s2 5000 mm/s2 5 0 0 0 Speed: V [mm/s] 100 200 300 400 500 600 700 900

/LECSS-T] Absolute 22bit encoder (Resolution: 4194304 p/rev) [With LECSC-T] Absolute 18bit encoder (Resolution: 262144 p/rev) specification Type Note 5) No excitation operating type Lock Holding force [N] 27 54 110 Power consumption [W] at 20Note 6) 6.3 7.9 7.9 Rated voltage [VDC] 24 0-10% Product Weight [kg] Model LEFB25 Stroke [mm] 300 400 500 600 700 800 900 1000 (1100) 1200 (1300) (1400

Strokes for Auto Switch Mounting Stroke Long stroke (2) (mm) Max stroke (mm) Number of switches Bore size (mm) Standard stroke (1) (mm) Auto switch model 2 1 D-C7/C8 D-B5/B6 D-H7 D-G5/K5 25, 50, 75, 100, 125, 150, 200 201 to 350 20 15mm 10mm 301 to 400 25 301 to 450 32 25, 50, 75, 100, 125, 150, 200, 250, 300 20mm 15mm 1500 301 to 800 40 D-B59W 301 to 1200 50/63 20mm 10mm D-H7LF 301 to 1400

1400 or less 1600 or less Order Made Made to Order Mounting Bracket Part No.

l/min (ANR) 4 4 Based on condition ; Based on condition ; IDU4D is selected as the model to process an air flow larger than 412 l/min IDF11C is selected as the model to process an air flow larger than 1400 l/min (ANR) with a 60Hz power supply, according to data D-2.

Applicable strokes: 250, 350, 450, 550, 650, 700, 750, 850, 900, 950, 1050, 1100, 1150, 1250, 1300, 1350, 1400, 1450 Example) LJ1H3031PD-250-F2-X2 Allowable Moment (Nm) Allowable static moment Allowable dynamic moment Pitching Rolling Yawing Mounting orientation Load movement direction 117 137 123 Model LJ1H30 Horizontal/Lateral Horizontal/Lateral Lateral Horizontal a Mep a = 1000 2000 L1

Order Made 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80 Symbol Specifications/Descriptions 1400 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 XA 100 Change of rod end shape 1500 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450,

The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized

Magnet: None, Mounting: L (Foot), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: TN (NPT), Stroke: 2000mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Lock

Magnet: None, Mounting: L (Foot), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: TN (NPT), Stroke: 1300mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Lock

Cylinder (Tube) Inner Diameter(φ): 200, Stroke(mm): 1300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Magnet: None, Mounting: Foot, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: NPT, Stroke: 2000mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Lock Unit Built-in

Cylinder (Tube) Inner Diameter(φ): 200, Stroke(mm): 1300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Thomas Oil-less Rotary Vane Compressor / Vacuum Pump Flow Rate: 33 LPM , 33 LPM, Max Pressure: 20.3 PSIG / 1400 mbar , 20.3 PSIG / 1400 mbar, Max Vacuum: 27.5 in HgV / -930 mbar , 27.5 in HgV / -930 mbar, Voltage (DC): 12, DC Motor Type: Standard, Item Dimensions: Length: 8.27 in / 210 mm Width: 2.32 in / 59 mm Height: 2.32 in / 59 mm , Length

Operating range Cylinder mounting bracket, by stroke/ Auto switch mounting surfaces 80 301 to 1400 100 301 to 1500 Note 1) Manufacture of intermediate strokes at 1 mm intervals is possible. (Spacers are not used.) Note 2) Long stroke applies to the axial foot and rod flange types.

Unit: N Operating pressure (MPa) Bore size (mm) Operating direction Rod size (mm) Piston area (mm2) 0.5 0.6 0.4 0.3 756 630 504 378 OUT 1260 40 20 566 472 377 283 IN 943 1180 980 784 588 OUT 1960 50 20 990 825 660 495 IN 1650 1870 1560 1250 934 OUT 3120 63 20 1680 1400 1120 840 IN 2800 422 A Clamp Cylinder CK1 Series Construction CKG140, 50, 63 Rod mounting type #0 q @1 w e @2 @0 !4 y !

Opening Range of Throttle Valve and Driving Speed Conditions: Operating pressure 0.5 MPa, Horizontal mounting, No load, Spring return side The speeds shown in the graph are for reference. 40 40 1400 50 50 1200 Piston speed (mm/s) Related things about auto switches and the mounting brackets part numbers are the same as these of Series CV3.

Based on condition y; IDFS11E is selected as the model to process an air flow larger than 1400 l/min (ANR) with a 60Hz power supply, according to data D-2. 4 4 Note) l/min (ANR) is for reference conditions of 20C, 1 ATM and 65% relative humidity. Data A: Correction Factor for Temperature (Series IDUS) Inlet air temp. (C) Outlet air press. dew point (C) Ambient temp.

Based on condition y; IDFS11E is selected as the model to process an air flow larger than 1400 l/min (ANR) with a 60Hz power supply, according to data D-2. 4 4 Note) l/min (ANR) is for reference conditions of 20C, 1 ATM and 65% relative humidity. Data A: Correction Factor for Temperature (Series IDUS) Inlet air temp. (C) Outlet air press. dew point (C) Ambient temp.