MC C1 CM ILS MC ILS V V CN CN MC V V CN CN PRS PRS IDFB37E IDFB55E/75E-46 CM GFCI R FM FM16 MC THR MC1 MC1 MC2 CM PE PRS MC2 PRS1 FM PE PRS2 PRR PRR ILS C01 THR W1 TB T TB1 W2 TB2 MC1 PRR C01 CM C1 MC2 PRS1 GFCI P PRS2 THR OLR P EDV PC EDV PE T V IDFB Series 6-4 6-3 IDX-OM-W035 6 6-5 (IDFB55E,75E) (IDFB22E,37E) ,, IDFB Series 6-5 6-4 IDX-OM-W035 7 K 7
Distance from cylinder axisr Lo (cm) lN = 145 lbs. 1 cm = 0.3937 inches LE E E Distance from cylinder axis: L0 (cm) z .a E E 0 t 2 3 4 5 6 7 8 9 1 0 1 1 Distance trom cylinder axis: Lo (cm) Series NCYZB Inner tube deflections Weight limitations of mounting hardware Intermediate position stop The NCY2B series does not allow direct mounting of the load.
I Plug Mount Type Panel Mount Type Specifications Action Single acting~sp ring return Symbol "" Max. operating pr.ess1J r~, . 7kgf/cm' 6 Min. , operating 2kgf! cm' I?r.essu~e ~19i'll15'. 1.5kgl! cm' 10.5kgf/ cm' Proof pressure 56a'C Ambient and fluid temperature ., Nil.
Set control range: 5.0 to 45.0 S/cm Flow switch Refer to the Best Pneumatics No. 8 for details. Refer to page 7.
Applicable model HRS-DI007 HRSH090-ll-l HRS 090 (Flying-out size) (314) Measurement range of electric conductivity 2.0 to 48.0 mS/cm HRS 100/150 Circulating fluid return port (263) Set range of electric conductivity target 5.0 to 45.0 mS/cm To circulating fluid return port o i Set range of electric conductivity hysteresis 2.0 to 10.0 mS/cm HRSH 090 HRSH 090 Operating temperature range (Circulating
(100 L/min 11 cm ) IN OUT PF3W504 PF3W520 (16 L/min ) (16 L/min ) (4 L/min ) (8 L/min ) [cm] [cm] PF3W540 PF3W511() (100 L/min ) (100 L/min ) (50 L/min ) (40 L/min ) (40 L/min ) (50 L/min ) [cm] [cm] -36No.PF-OMN0009CN-F PF3W521() (250 L/min ) (250 L/min ) [cm] -37No.PF-OMN0009CN-F PVC 3F.S.11 cm IN OUT PF3W511/521(PVC ) (100 L/min ) (250 L/min ) [cm] -38No.PF-OMN0009CN-F PF3W504S
[] a b MPa 0.00025 -0.25 kPa 0.25 -250 kgf/cm 2 0.002549 -2.549 ISE70 bar 0.0025 -2.5 psi 0.03626 -36.26 MPa 0.0004 -0.4 kPa 0.4 -400 kgf/cm 2 0.004079 -4.079 ISE71 bar 0.004 -4 psi 0.05802 -58.02 [] (ISE70 MPaPD=2000 ) Pr = a (PD) + b = 0.00025 2000 0.25 = 0.25[MPa] (ISE70 MPaPr=0.75[MPa]) (PD) = (Pr b) / a = [0.75 (-0.25)]/0.00025 = 4000 -63No.PS-OMV0003CN-G IO-Link IODD IODD(I
+COM COM N PROFIBUS-DP (SDNW) Note 1) Indicate the size in the specification order sheet in the case of CM.
to load's center of gravity (cm) 32 6 10 15 20 Bore size (mm) 40 6.48 3.6 + Lo 15 5 + Lo 45.5 6.5 + Lo 80.7 8 + Lo Allowable load mass (WA) (kg) 6.
9 Wear ring CM-020-07-301A CM-025-07-302A CM-032-07-304A C1A040-07-305A Resin @0 Piston gasket SO-012-13 SO-010-22 SO-010-23 SO-013-7 NBR @1 Cylinder tube gasket CM-020-16-123 CM-025-16-124 CM-032-16-126 CM-040-16-127 NBR @2 Rod seal PDU-10Z PDU-12LZ PDU-12LZ PDU-16Z NBR @3 O ring SO-017-30 SO-017-32 SO-017-34 SO-017-36 NBR @4 O ring SO-015-23 SO-015-23 SO-017-36 SO-017-37 NBR @5 4.10-10
J DT-bracket Bore size (mm) Foot (1) Double clevis (with pin) (2) Flange Single clevis 6 CJ-T010B CJK-L016B CJK-F016B -X 10 16 CJ-T016B CLJ-L016B CLJ-F016B 2020 CM-L020B CM-F020B CM-D020B CM-C020B 25 CM-L032B CM-F032B CM-D032B CM-C032B Data Note 1) 2 foot brackets and 1 mounting nut are attached. Note 2) Clevis pin and snap ring are included in package.
The unit is [S/cm] (siemens/centimeter). The lower the electric conductivity, the more difficult the electricity flows in the fluid. On the contrary, the higher the electric conductivity, the easier the electricity flows in the fluid. The minimum electrical conductivity for fluids for this sensor is 5uS/cm. Conductivity of tap water is 100 to 200S/cm.
When deionized water is used, the conductivity should be 1S/cm or higher (Electrical resistivity: 1Mcm or lower). Open the fluid supply valve that is connected to the automatic water fill port. Fluid supply starts and stops automatically with the ball tap in the tank. Confirm that the fluid level is between HIGH and LOW level of the fluid level gauge.
Pure water with a resistivity of not more than 4.5 M/cm (0.22 S/cm or more) can be used as the circulating fluid.
J DBore size (mm) Foot (1) Double clevis (with pin) (2) T-bracket Flange Single clevis 6 CJ-T010B CJK-L016B CJK-F016B -X 10 16 CJ-T016B CLJ-L016B CLJ-F016B 2020 CM-L020B CM-F020B CM-D020B CM-C020B 25 CM-L032B CM-F032B CM-D032B CM-C032B Data Note 1) 2 foot brackets and 1 mounting nut are attached. Note 2) Clevis pin and snap ring are included in package.
The standard cable length for F9BA is 3m. 1 High Precision Scale Cylinder Series CEP1 Cylinder Specifications Double acting single rod (non-rotating piston) Action Air Fluid 1.5MPa {15.3kgf/cm} Proof pressure Maximum operating pressure 1.0MPa {10.2kgf/cm} 12 20 Minimum operating pressure 0.15MPa {1.5kgf/cm} 0.1MPa {1.0kgf/cm} 50 to 300mm/s Piston speed Ambient & fluid temperature 0C to 60C
Description Material 25 PDU-10Z PPD-25-19 CM-025-16-124 32 PDU-12LZ PPD-32 CM-032-16-126 40 PDU-16Z PPD-40 CM-040-16-127 50 63 80 PDU-25Z PPD-80 CM-080-16-152 100 PDU-30Z PPD-100 CM-100-16-153 Rod seal Piston seal Tube gasket NBR NBR NBR PDU-20Z PDU-20Z @4 @5 @6 PPD-50 CM-050-16-128 PPD-63 CM-063-16-129 With air cushion (Parts @4 to @6 are the same as rubber bumper style.)
Downstream side oil mist concentration Element service life Flow rate L/min (ANR) Note 3) 2 years or when the pressure drop becomes 0.1MPa 330 Polycarbonate 25 Relieving type 0.59 150 820 Bowl material Drain capacity cm Construction Weight kg Accessories Bowl guard 8 45 0.44 1.25 Accessory part no. Note 1) Assembly includes a bracket and set nuts.
Mounting Bracket Part Numbers Bore size (mm) Foot Note 1) Double clevis (with pin) Note 2) T-bracket Note 3) Flange Single clevis 6 CJK-L016B CJ-T010B CJK-F016B 10 CLJ-L016B CJ-T016B CLJ-F016B 16 CM-L020B CM-F020B CM-D020B CM-C020B 20 CM-L032B CM-F032B CM-D032B CM-C032B 25 Note 1) Two foot brackets and one mounting nut are included.
Cylinder port U D U D C8 C10 C12 02 03 B CM With One-touch fitting for 8 With One-touch fitting for 10 With One-touch fitting for 12 Rc 1/4 Rc 3/8 Bottom ported Rc 1/4 Mixed Refer to page 2-5-2 (Grommet type) for wiring specifications.