SMC Corporation of America
Elite Part Number Search
Search Results "CQ2B63V-75D"

Magnet: None, Mounting: Through Hole [Standard], Bore Size: Ø63 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Water Resistant Seal: FKM Seal, Fluororubber, Stroke: 40 mm, Body Option: Rod End Male Thread, Auto Switch Groove: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: None, Mounting: Through Hole [Standard], Bore Size: Ø63 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Water Resistant Seal: FKM Seal, Fluororubber, Stroke: 30 mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: None, Mounting: Through Hole [Standard], Bore Size: Ø63 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Water Resistant Seal: FKM Seal, Fluororubber, Stroke: 30 mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.08~1.0, Support bracket: Through-hole, Port thread type: Rc, Body Options: -, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: -, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: -, Valves: -, Operating Pressure(MPa): 0.08~1.0, Operating Pressure(MPa): -, Specification

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: -, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: -, Valves: -, Operating Pressure(MPa): 0.08~1.0, Operating Pressure(MPa): -, Specification

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.08~1.0, Support bracket: Through-hole, Port thread type: Rc, Body Options: -, Auto Switches: Without

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25

Low friction characteristics are improved with the use of the CQ2X low speed cylinder series. Minimum operating pressure is cut in half, compared to previous series, while achieving stable thrust. All microspeed cylinders have the same dimensions as the standard cylinders.CQ2, low friction type, Mountings: 6 options available, Bore sizes: 32mm, 40mm, Strokes up to 100mm as standard, Auto

Low friction characteristics are improved with the use of the CQ2X low speed cylinder series. Minimum operating pressure is cut in half, compared to previous series, while achieving stable thrust. All microspeed cylinders have the same dimensions as the standard cylinders.CQ2, low friction type, Mountings: 6 options available, Bore sizes: 32mm, 40mm, Strokes up to 100mm as standard, Auto

Low friction characteristics are improved with the use of the CQ2X low speed cylinder series. Minimum operating pressure is cut in half, compared to previous series, while achieving stable thrust. All microspeed cylinders have the same dimensions as the standard cylinders.CQ2, low friction type, Mountings: 6 options available, Bore sizes: 32mm, 40mm, Strokes up to 100mm as standard, Auto

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Magnet: None, Mounting: G (Rear Flange), Bore Size: 32mm, Port Thread Type: Rc (or Metric), Stroke: 75mm

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: