SMC Corporation of America
Elite Part Number Search
Search Results "CXSL20-90-Z73"

After that, incline the lever by 90 and confirm that the indicator light is not on and does not show either red or green.

Sine Rodless Cylinder Series REBR Direct Mount Type/15, 25, 32 How to Order REB R 25 300 Z73 Number of auto switches Sine rodless cylinder 2 pcs. Nil 1 pc. S n "n" pcs.

to the D-B53/B54, D-C73(C)/C80C, D-A93(V), D-A73(C)/A80C, DA53/A54, D-Z73, and D-90/97/90A/93A only. 4) For reed auto switches M8 and M12 type with connector, please contact SMC. 5) The standard lead wire length of the trimmer auto switch is 3 m. 6) The standard lead wire length of the solid state auto switch with the timer except for the D-P3DW and D-M9A (V), water-resistant 2-color

Turntable Cylinder Series MGT 63, 80, 100 Flat cylinder with guide (Series MGP) and manual turntable combination Turntable Cylinder Series MGT 63, 80, 100 Flat cylinder with guide (Series MGP) and manual turntable combination High precision bearings for smooth turning return movement Table unit has positioning mechanisms for each 90 and 180 of rotation 180 90 Rotation position is detected

As a rule, it can be turned about 90 past the point at which tightening can be felt. Flat head watchmakers screw driver Auto switch 5 to 6 Switch mounting screw (M2.5 x 4l) (included) Auto Switch Specifications (1) Switches (switch rail) can be added to the standard type (without switch rail).

As a rule, it can be turned about 90 past the point at which tightening can be felt. Flat head watchmakers screw driver Auto switch 5 to 6 Switch mounting screw (M2.5 x 4l) (included) Auto Switch Specifications (1) Switches (switch rail) can be added to the standard type (without switch rail).

Mounting from top Mounting from bottom Typical application Change of transfer direction Positioning Features 2 40, 63, 100 Series MGF Guide Table How to Order 63 30 Z73 MGF Guide Table Number of auto switches 2 pcs. Nil 1 pc. S Auto switch type Nil Without auto switch Refer to the table below for auto switch model numbers.

Mounting from top Mounting from bottom Typical application Change of transfer direction Positioning Features 2 40, 63, 100 Series MGF Guide Table How to Order 63 30 Z73 MGF Guide Table Number of auto switches 2 pcs. Nil S 1 pc. Auto switch type Nil Without auto switch Refer to the table below for auto switch model numbers.

Lead wire length indication Note 1) Applicable auto switch with 5 m lead wire (Z) Reed switch: D-B53/B54, DC73(C)/C80C, D-A73(C)(H)/ A80C, D-A53/A54, D-Z73, D90/97/90A/93A Solid state switch: Manufactured upon receipt of order as standard.

Lead wire length indication Note 1) Applicable auto switch with 5 m lead wire (Z) Reed switch: D-B53/B54, DC73(C)/C80C, D-A73(C)(H)/ A80C, D-A53/A54, D-Z73, D90/97/90A/93A Solid state switch: Manufactured upon receipt of order as standard.

The tightening torque should be approximately 0.05 to 0.1Nm. 7 Reed Switches/Direct Mount Type D-Z73/Z76/Z80 Auto Switch Specifications With indicator light D-Z73 D-Z76 Auto switch part no.

The tightening torque should be approximately 0.05 to 0.1Nm. (0.04 to 0.07 ft lb) 10 Clean Room Rodless Cylinder Series CYP Reed Switches/Direct Mount Type D-Z73/Z76/Z80 Auto Switch Specifications With indicator light D-Z73 D-Z76 Auto switch part no.

The tightening torque should be approximately 0.05 to 0.1Nm. (0.04 to 0.07 ft lb) 10 Clean Room Rodless Cylinder Series CYP Reed Switches/Direct Mount Type D-Z73/Z76/Z80 Auto Switch Specifications With indicator light D-Z73 D-Z76 Auto switch part no.

As a rule, it should be turned about 90 past the point at which tightening can be felt.

As a rule, it should be turned about 90 past the point at which tightening can be felt.

Applications Press Chuck Pusher Shooter Lifter Features 2 Non-rotating Double Power Cylinder Series MGZ 40, 50, 63 How to Order MGZ 100 40 Z73 Standard Type Number of auto switches Mounting 2 pcs. 1 pc.

90 90 6.5 6.0 6.0 8.0 8.0 43 43 43 14 14 14 15 17 17 21 21 16 16 18.5 15 17 17 21 21 16 16 18.5 0 0.2 0 0.2 0 0.2 64 72 80 Without rod boot With rod boot Bore size (mm) J GC H1 K KA L MM N RR P S U W H Z ZZ e f h Z ZZ 252 281 304 356 390 466.5 488 530 l 84 90 98 116 126 98 98 106 1/4 3/8 3/8 1/2 1/2 1/2 1/2 3/4 1/4 stroke 1/4 stroke 1/4 stroke 1/4 stroke 1/4 stroke 1/5 stroke 1/5 stroke

Note 1) 75 + 50 (n 2) (n = 2, 4, 6, 8) Note 1) 80 + 50 (n 2) (n = 2, 4, 6, 8) Note 1) 85 + 50 (n 2) (n = 2, 4, 6, 8) Note 1) 90 + 50 (n 2) (n = 2, 4, 6, 8) Note 1) 1 70 75 80 85 90 D-F5l/J59 D-F5lW D-J59W D-F5BA D-F59F 2 (Different surfaces, same surface) 90 95 110 115 120 130 n (Same surface) 90 + 55 (n 4) 2 (n = 4, 8, 12, 16) Note 2) 95 + 55 (n 4) 2 (n = 4, 8, 12, 16) Note 2) 110

90 90 27 32 32 37 37 47 47 53 32 40 40 52 52 60 70 86 102 116 145 161 182 6.5 6.0 6.0 8.0 8.0 43 43 43 22 27 27 32 41 14 14 14 71 81 101 119 133 145 160 180 9.0 9.0 11.5 13.5 13.5 19 19 19 12 12 15 18 18 14 20 20 80 90 105 130 150 190 212 236 42 50 59 76 92 100 112 118 100 110 130 160 180 230 255 275 60 70 86 102 116 15 17 17 21 21 16 16 18.5 15 17 17 21 21 16 16 18.5 11 11 11 11 11 16 16

100 105 110 D-Y7BA n 85 + 45 (n 4) 2 (n = 4, 8, 12, 16)*2 90 + 45 (n 4) 2 (n = 4, 8, 12, 16)*2 100 + 45 (n 4) 2 (n = 4, 8, 12, 16)*2 105 + 45 (n 4) 2 (n = 4, 8, 12, 16)*2 110 + 45 (n 4) 2 (n = 4, 8, 12, 16)*2 2 (Different surfaces, same surface) 1 90 95 100 105 110 D-P3DWA n (Different surfaces, same surface) 90 + 50 (n 4) 2 (n = 4, 8, 12, 16)*2 95 + 50 (n 4) 2 (n = 4, 8, 12, 16)*