Body tapped Stroke (mm) Model Reed switch D-A9, D-A9V 10 20 30 50 75 100 MXF8 8 Solid state switch D-M9, D-M9V MXF12 12 2-color indication solid state switch D-F9W, D-F9WV MXF16 16 MXF20 20 8-6-1 2 Low Profile Slide Table Series MXF 8, 12, 16, 20 How to Order MXF 12 50 M9N S Number of auto switches Nil S n 2 pcs. 1 pc. n pcs.

Output Power Current Load Load Current Applicable voltage consumption voltage current leakage load drop D-M9N D-M9NV D-M9NW D-M9NWV NPN DC28V type or less At 10mA DC512 0.8V or 100A or Relay 10mA 40mA less less at PLC 24V or less or less IC circuit D-M9P D-M9PV D-M9PW D-M9PWV DC24V (4.5 to 28V) At 40mA 2V or less PNP type D-M9B D-M9BV D-M9BW D-M9BWV DC24V DC24V 2.5 to 4V 0.8mA or less (DC10

7 51.5 20.5 33.5 51.5 20.5 26.5 30.5 20.5 39 29 19 29 27 35 67 70 75 19 8 71.5 23.5 39.5 74.5 77.5 33.5 31.5 43.5 33.5 48 38 28 28 42 42 56 84 75 22 9 60.5 32.5 46.5 88.5 88.5 42.5 46.5 52.5 32.5 Solid state auto switch: D-M9B, D-M9N Stroke B Stroke E Auto switch operating range Model A 40 50 150 75 100 10 20 30 125 75 100 150 20 30 125 10 40 50 13-/22-MXQ6(L) 0.5 0.5 0.5 7.5 7.5 9.5 9.5

Auto Switch Proper Mounting Position (Detection at Stroke End) D-A93 12 16 to 25 A B W A B W D-M9B/M9N 12 16 to 25 A B W A B W B D-A93 B D-M9B/M9N/M9P Bore size (mm) A 11.5 W 4 A 15.5 W 5.5 12 16 20 25 0.5 4.5 12 0 4.5 16 4 6 16 3.5 1 20 7.5 2.5 17 5.5 -1 21 9.5 0.5 Specific Product Precautions Be sure to read this before handling. Mounting Caution 1.

Solid state auto switch: D-M9B, D-M9N B E Model Auto switch operating range Stroke Stroke A 40 50 150 100 75 100 10 20 30 125 75 20 30 125 150 10 40 50 13-/22-MXS6 0.4 0.4 0.4 11.6 17.5 9.6 9.6 9.6 21.6 27.6 1.5 10 13-/22-MXS8 4.9 0.1 0.9 8.9 16.9 41.9 14.9 9.9 10.9 18.9 26.9 51.9 1.5 11.6 13-/22-MXS12 74.4 32.4 22.4 12.4 14.4 24.4 22.4 12.4 2.4 4.4 14.4 35.4 64.4 2.5 45.4 15.6 13-/22

less 50 mA, 40 mA, 20 mA IC circuit, Relay, PLC No Reed auto switch D-A90 D-M9B, D-F8B D-M9N, D-F8N 2-wire 3-wire 24 VDC relay, PLC 24 VDC relay, PLC Solid state auto switch Yes 24 VDC (10 to 28 VDC) 24 VDC (4.5 to 28 VDC) Yes 2.5 to 40 mA 40 mA or less Refer to page 920 for the applicable auto switch list. 909 Rotary Table MSQ 1122Specifications Suction Flow Rate of Vacuum Suction Type

D B Reed auto switch D-A93 Solid state auto switch D-M9B, D-M9N Stroke (mm) Auto switch operating range 10 34.5 35.5 14.5 15.5 Stroke (mm) Auto switch operating range 10 30.5 31.5 18.5 19.5 Model Model 5 25.5 26.5 13.5 14.5 A B C D A B C D 11-/22-MXP6 5 11-/22-MXP6 3 11-/22-MXP10, 12, 16 Electrical entry from outside Electrical entry from inside Parallel electrical entry B A B B A A Solid

Grade 2 Grade 2 Rubber stopper Grade 4 Grade 4 Metal stopper Auto switches / Proper mounting position for stroke end detection 11-/22MXP6 A A C D D B Reed switch D-A93 Solid state switch D-M9B, D-M9N Stroke (mm) Auto switch operating range 10 34.5 35.5 14.5 15.5 Stroke (mm) Auto switch operating range 10 30.5 31.5 18.5 19.5 Model Model 5 25.5 26.5 13.5 14.5 A B C D A B C D 11-/22-MXP 6

30 40 13 XL-OMY0002 8 X L D 25 M9N A A ( X A N1 A ) 25 40 B A 50 63 80 C P11 160 100 FKM() P8 KF (NW) D K (DN) () A / A F G A J B K C L M M9N D-M9N M9P D-M9P / 560 M9B D-M9B A90 D-A90 H0 H4 H5 5150 100 A93 D-A93 120 M9// 25H4 14 XL-OMY0002 9. 200 2580 100 100,160 [] 1 1.5 1 XLD-25,XLD-40,XLD-50,XLD-63,XLD-80 200 XLD-100,XLD-160 100 : FKM 110 Pa <> 15 XL-OMY0002

Auto switch Auto Switch Specifications D-M9N(With indicator light) Auto switch model D-M9N Electrical entry direction In-line Wiring 3-wire Output NPN type Applicable load IC circuit,Relay,PLC Power supply voltage DC51224V(4.5 to 28V) Current consumption 10 mA or less Load voltage Load current 40 mA or less Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA) Current leakage

+ 30 (n 2) (n = 2, 3, 4) D-G39 D-K39 D-A3m n (Same surface) 100 + 100 (n 2) (n = 2, 3, 4) 1 10 2 (Different surfaces) 35 2 (Same surface) 50 n (Different surfaces) 35 + 30 (n 2) (n = 2, 3, 4) D-A44 n (Same surface) 50 + 50 (n 2) (n = 2, 3, 4) 1 10 D-F5m D-J59 D-F5mW D-J59W D-F5BA D-F59F 2 (Different surfaces, same surface) 1 15 n 15 + 55 (n 2) 2 (n = 2, 4, 6, 8)*1 2 (Different surfaces

D-M9mWV D-M9mA D-M9mAV D-A9m D-A9mV D-F5m D-J59 D-F59F D-F5NT D-A5m D-A6m D-A59W D-G39 D-K39 D-A3m D-A44 D-P3DWA D-P4DW Bore size A B A B A B A B A B A B A B A B A B A B 32 10 8 6 4 6.5 4.5 11.5 9.5 0 0 4 2 0 0 3.5 1.5 5.5 3.5 3 1 40 9 9 5 5 5.5 5.5 10.5 10.5 0 0 3 3 0 0 2.5 2.5 4.5 4.5 2 2 50 10 9 6 5 6.5 5.5 11.5 10.5 0 0 4 3 0 0 3.5 2.5 5.5 4.5 3 2 63 10 9 6 5 6.5 5.5 11.5 10.5 0 0 4

D-G5NT D-G5lW D-K59W D-G5BA D-G59F D-F5l D-J59 D-F59F D-F5lW D-J59W D-F5BA D-M9l D-M9lV D-M9lW D-M9lWV D-M9lA D-M9lAV D-B5l D-B64 D-A9l D-A9lV D-A59W D-F5NT D-P3DWA D-P4DW Bore size A B A B A B A B A B A B A B A B A B A B A B 40 10 8 6 4 4 1 5.5 3.5 3.5 0.5 0.5 0 1 0 7 4 2.5 0 4.5 1.5 12 9 50 10 8 6 4 3.5 1.5 5.5 3.5 3 1 0 0 0.5 0 6.5 4.5 2 0 4 2 11.5 9.5 63 12.5 11.5 8.5 7.5 6 5 8 7 5.5

D Lever type models Caution RS (D) 32/40/50-L RS (D) 32/40/50-B RS (D) 32/40/50-C RS (D) 32/40/50-D RS (D) 32/40/50-E Mounting base 1. Do not allow a pallet to collide with the cylinder when the lever is upright.

B A C D A B C D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 6 46 26 46 26 30 42 42 30 10 48 28 48 28 32 44 44 32 Electrical entry (Fetching direction) Type Model Features D-A90 D-Z80 D-Y69A D-Y69B D-Y7PV D-Y7NWV D-Y7PWV D-Y7BWV 50, 63 Grommet (In-line) Without

Series MHL2 112210, 16, 20, 25, 32, 40 Parallel Type Wide Opening Air Gripper How to Order 11 Vacuum suction type Clean series 11MHL 2 16 D 1 M9N 22MHL 2 16 D 1 M9N Wide opening Number of auto switches 2 pcs. 1 pc. n pcs.

REC A dimension B dimension Auto switch model CX D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C D-F7V/F7WV D-F7BA D-F79F D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C D-F7V/FWV D-F7BA D-F79F CY D-F7NTL D-A73/A80 D-F7NTL D-A73/A80 MQQ M Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800

REC A dimension B dimension Auto switch model CX D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C D-F7V/F7WV D-F7BA D-F79F D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C D-F7V/FWV D-F7BA D-F79F CY D-F7NTL D-A73/A80 D-F7NTL D-A73/A80 MQQ M Bore size (mm) RHC 10 35 35.5 45 44.5 40.5 39.5 MK(2) 15 34.5 35 62.5 62 40 57 20 64 64.5 50 49.5 69.5 44.5 RS Q G 25 44 44.5 71 70.5 49.5

Note D-F7/J79 D-F7V D-J79C D-F7W/J79W D-F7WV D-F7BAL/F7BAVL D-F79F D-F7NTL Switch mounting screw RS H A 20, 25 BQ-1 (M3 x 0.5 x 8l) Square nut D-A7/A8 D-A73C/A80C D-A7H/A80H D-A79W RZQ Switch mounting screw 32, 40 50, 63 Magnetic body (Steel plate, etc.)

entry is not available for 50 and 63. ( ) D-Y69A, D-Y69B, D-Y7PV D-Y7NWV, D-Y7PWV, D-Y7BWV 8-12-23 24 Series MY1W Mounting of Auto Switch & Installation of Lead Wire Cover (50, 63) Caution Be sure to install a lead wire cover on the auto switches for size 50 and 63 cylinders.