Please contact us for the latest version.sales@ocaire.com, HOUSING (FH100-16-510), OTHERS, FHG HYDRAULIC FILTER, 2X, FHG NO SIZE RATNG, 15.43235 lb, ModelPort size (Rc)Rated flow rate (l/min) PaperMicromeshFH100-162260300
Max Operating Pressure: 3.5 MPa, Construction: Element Upward Removal, Threaded, Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: Differential Press. Indicator, Construction 42 Only, Relief Valve: None, Fluid: Water-glycol, Emulsion, Element: Paper, Filtration: 20μm, Fluid Direction: -, Made to Order: -
Max Operating Pressure: 3.5 MPa, Construction: Element Upward Removal, Threaded, Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: Differential Press. Indicator, Construction 42 Only, Relief Valve: None, Fluid: Water-glycol, Emulsion, Element: Micromesh, Filtration: 20μm, Fluid Direction: IN Left, Made to Order: Non-standard Filtration
Max Operating Pressure: 3.5 MPa, Construction: Element Upward Removal, Threaded, Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: Differential Press. Indicator, Construction 42 Only, Relief Valve: None, Fluid: Water-glycol, Emulsion, Element: Micromesh, Filtration: 3μm, Fluid Direction: IN Left, Made to Order: Non-standard Filtration
Construction: Common w/L-type Thread & Flange, Port Size: 3/4, Pressure Indicator: Differential Pressure Indicator, Relief Valve: None, Fluid: Water-glycol, Emulsion, Filtration: 149μm, Flange: -
Max Operating Pressure: 3 (3.5 MPa), Construction: 42 (Element Upward Removal, Threaded), Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: 4 (Differential Press. Indicator, Construction 42 Only), Relief Valve: 1 (None), Fluid: 1 (Water-glycol, Emulsion), Element: P (Paper), Filtration: 20μm
Max Operating Pressure: 3 (3.5 MPa), Construction: 42 (Element Upward Removal, Threaded), Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: 4 (Differential Press. Indicator, Construction 42 Only), Relief Valve: 1 (None), Fluid: 1 (Water-glycol, Emulsion), Element: M (Micromesh), Filtration: 20μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)
Max Operating Pressure: 3 (3.5 MPa), Construction: 42 (Element Upward Removal, Threaded), Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: 4 (Differential Press. Indicator, Construction 42 Only), Relief Valve: 1 (None), Fluid: 1 (Water-glycol, Emulsion), Element: M (Micromesh), Filtration: 3μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)
Construction: 90 (Common w/L-type Thread & Flange), Port Size: 06 (3/4), Pressure Indicator: 4 (Differential Pressure Indicator), Relief Valve: 1 (None), Fluid: 1 (Water-glycol, Emulsion), Filtration: 149μm
FH series suction filters are compact and lightweight. Designed with an aluminum casted housing. Element can be replaced by simply opening the cover to detach the element without touching the pipes. The filter can be fitted with a differential pressure indicator which senses when the element is becoming dirty, facilitating maintenance and helping to avoid pump damage such as cavitations.
Construction: Common w/L-type Thread & Flange, Port Size: 3/4, Pressure Indicator: Differential Pressure Indication Switch, Relief Valve: Relief Valve, Fluid: Petroleum, Filtration: 105μm, Flange: -
Construction: Common w/L-type Thread & Flange, Port Size: 3/4, Pressure Indicator: Differential Pressure Indicator, Relief Valve: None, Fluid: Petroleum, Filtration: 105μm, Flange: -
Construction: 90 (Common w/L-type Thread & Flange), Port Size: 06 (3/4), Pressure Indicator: 5 (Differential Pressure Indication Switch), Relief Valve: 0 (Relief Valve), Fluid: 0 (Petroleum), Filtration: 105μm
Construction: 90 (Common w/L-type Thread & Flange), Port Size: 06 (3/4), Pressure Indicator: 4 (Differential Pressure Indicator), Relief Valve: 1 (None), Fluid: 0 (Petroleum), Filtration: 105μm
Construction: 90 (Common w/L-type Thread & Flange), Port Size: 06 (3/4), Pressure Indicator: 5 (Differential Pressure Indication Switch), Relief Valve: 1 (None), Fluid: 0 (Petroleum), Filtration: 105μm
T Dimension, mm: 2 (Port 1/2-1: 380, 1 1/4-2: 485, 2 1/2-3: 650), Filtration: 105μm, Port Size: 06 (3/4), Pressure Indicator: 5 (Differential Pressure Indication Switch), Connection: 2 (L-block Companion Flange), Air Breather: C (Cap)
Fluid: Petroleum, Port Size Category: 1/2, 3/4, 1, Std. T Dimension, mm: Port 1/2-1: 380, 1 1/4-2: 485, 2 1/2-3: 650, Filtration: 105μm, Port Size: 3/4, Pressure Indicator: Differential Pressure Indication Switch, Connection: L-block Companion Flange, Air Breather: Cap
Type: -, Type: Return filter, Hydraulic fluid: Petroleum series, Connection Port Size: Rc3/4, Nominal filtration(μm): 74, Differential pressure display: Differential pressure indicator, Relief valve: With Relief valve, O-ring nominal size: N/A, Element: Micro-mesh, Made-to-order specifications: None (standard), Compatible filter type: N/A, Related component type: N/A
Type: -, Type: Return filter, Hydraulic fluid: Petroleum series, Connection Port Size: Rc3/4, Nominal filtration(μm): 270, Differential pressure display: Differential pressure indicator, Relief valve: With Relief valve, O-ring nominal size: N/A, Element: Micro-mesh, Made-to-order specifications: Non-standard nominal filtration, Compatible filter type: N/A, Related component type: N/A
Type: -, Type: Return filter, Hydraulic fluid: Petroleum series, Connection Port Size: Rc3/4, Nominal filtration(μm): 20, Differential pressure display: Differential pressure indicator, Relief valve: With Relief valve, O-ring nominal size: N/A, Element: Paper, Made-to-order specifications: None (standard), Compatible filter type: N/A, Related component type: N/A