Cylinder side pressure (P2) SV Specifications Max. operating pressure Min. operating pressure Ambient and fluid temp.

For subsonic range Where P1 + 0.1013 = (1 to 1.8941) (P2 + 0.1013) Formula based on Cv factor Q = 4073.4Cv P (P2 + 0.1013) l/min (ANR) Other Formula based on effective area Q = 226.3S P (P2 + 0.1013) l/min (ANR) 1. Materials NBR: Nitrile rubber FKM: Fluoro rubber Trade names: Viton, Dai-el, etc. 2.

For subsonic range Where P1 + 0.1013 = (1 to 1.8941) (P2 + 0.1013) Formula based on Cv factor Q = 4073.4Cv P (P2 + 0.1013) l/min (ANR) Other Formula based on effective area Q = 226.3S P (P2 + 0.1013) l/min (ANR) 1. Materials NBR: Nitrile rubber FKM: Fluoro rubber Trade names: Viton, Dai-el, etc. 2.

How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 +0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q: Air flow rate [l/min(ANR)] S: Effective area (mm) P: Pressure drop (P1-P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Maintenance Correction for different air temperatures

Analog Output Characteristics Hysteresia mode when the values of P1 and P2 are equal or when P1>P2 but within 3 digits, the hysteresis will be automatically set to 3 digits tor the set value ot P1. Window comparator mods The hysteresis is automatically set to 3 digits, so separate P1 trom P2 by 7 digils or more when programming.

Analog Output Characteristics Hysteresia mode when the values of P1 and P2 are equal or when P1>P2 but within 3 digits, the hysteresis will be automatically set to 3 digits tor the set value ot P1. Window comparator mods The hysteresis is automatically set to 3 digits, so separate P1 trom P2 by 7 digils or more when programming.

Model Option 10-/21-AW20(K)-B 10-/21-AW30(K)-B 10-/21-AW40(K)-B 10-/21-AW40(K)-06-B 10-/21-AW60(K)-B Bracket assembly Note 1) AW23P-270AS AR33P-270AS AR43P-270AS AW62P-270AS Set nut Note 2) AR23P-260S AR33P-260S AR43P-260S 10: G49-10-01, 21: G49-10-01-MS-X3 Round type Note 3) Pressure gauge Note 4) Standard 10: G49-4-01, 21: G49-4-01-MS-X3 0.02 to 0.2 MPa setting Note 1) Assembly of a bracket

TB Td TE TF TH TN Rod End Nut CG-020-24A CG-025-24A CG-032-24A CG-040-24A CG-050-24A CG-063-24A CG-080-24A CG-100-24A 3.2 3.2 4.5 4.5 6 8 11 12 (29.3) (33.1) (40.4) (49.2) (60.4) (74.6) 28 01 13 15 17 21 24 26 36 50 36 43 50 58 70 82 73 90 8 10 12 14 16 18 18 22 10 10 10 10 20 20 5.5 5.5 6.6 6.6 9 11 11 13.5 25 30 35 40 50 60 55 65 RZQ 03 32 01 03 Applicable bore (mm) 20 25 32 40 50 63

<> (01-144) D RESET SVON <> <>(M24V) (01-145) RESET SVON D <> <> <> RESET SVON (01-146) D <> -65- <> <>(C24V) RESET SVON (01-147) D <> <> <> (01-148) RESET SVON D <> <> (01-149) D RESET SVON <> () Communicati on error. (01-150) D RESET SVON <> (01-192) E <> <> <> ON(SVONON) (01-193) E <>ON(SVON ON) <> Output current limit is exceeded set value (

When the I/alues 01 P1 and P2 are equal 0<" when Pi > P2 but Wlthm 2 digits. the hystereSIs Will be au1omatll~ally set 102 digits for lhe sell/alue 01 PI An error code is displayed when overcurrent, excessive pressure, data error, or pressure during O-clear occurs.

Model Option 10-/21-AR20(K)-B 10-/21-AR25(K)-B 10-/21-AR30(K)-B 10-/21-AR40(K)-B 10-/21-AR40(K)-06-B 10-/21-AR50(K)-B 10-/21-AR60(K)-B Bracket assembly Note 1) AR50P-270AS Note 2) AR20P-270AS Note 3) Note 3) AR25P-270AS AR30P-270AS AR40P-270AS Set nut AR20P-260S AR25P-260S AR30P-260S AR40P-260S 10: G49-10-01, 21: G49-10-01-MS-X3 Standard Pressure gauge Note 4) 10: G49-4-01, 21: G49-4-01

(P2+0.1013) Calculation by Cv factor Q=1972.8.Cv.

I Shock resistance 100G to X, Y, 2 direction ( 3 times for each direction) Weight 1269 (Incl. 3m-long lead wire) Nolel)eHysleresls mode ZSE When the values 01 PI and P2 are the same or when PI >P2 wlthlll 2digits, the hysteresis will be aulomahcally 2digits for the set value of PI.

M plug connector 2 position double: VZS2250-M(Z)-01 3 position closed center: VZS2350-M(Z)-01 3 position exhaust center: VZS2450-M(Z)-01 3 position pressure center: VZS2550-M(Z)-01 DIN terminal 2 position double: VZS2250-D(Z)-01 3 position closed center: VZS2350-D(Z)-01 3 position exhaust center: VZS2450-D(Z)-01 3 position pressure center: VZS2550-D(Z)-01 Applicable cable O.D.: 3.5 to 7 MAX

G46-10-01 2 pcs. G27-10-R1-X209 2 pcs. G27-10-R1-X209 2 pcs. G46-10-01 2 pcs.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 KFT04-01 KFT04-02 KFT06-01 KFT06-02 KFT06-03 KFT08U-01 KFT08U-02 KFT08U-03 KFT08N-01 KFT08N-02 KFT08N-03 KFT10U-02 KFT10U-03

VAC 100 VN SY100-82-2-01 200 VAC 200 VN SY100-82-2-02 110 VAC (115 VAC) 110 VN SY100-82-2-03 220 VAC (230 VAC) 220 VN SY100-82-2-04 When making connections, please note that using other than the supported size (3.5 to 7) heavy-duty cord will not satisfy IP65 (enclosure) standards.

AN110-01 AN200-02 AN200-02 AN110-01 For a silencer to be mounted in a single valve unit, refer to page 2-7-5.