Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: JM (J + M)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: JM (w/Automatic Fluid Fill Function + Applicable to Deionized Water Piping)
Cooling Method: Air-cooled Refrigeration, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz), Option: w/Automatic Fluid Fill Function + Applicable to Deionized Water Piping
Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: J + M
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: J + M
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: JM (J + M)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: JM (J + M)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 (3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz)), Option: JM (w/Automatic Fluid Fill Function + Applicable to Deionized Water Piping)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, THERMO-CHILLER, OTHERS, HRS THERMO-CHILLERS, 2X, HRS - NO SIZE RATING, 152.11896 lb
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024, HRS030; SMC recommends Bypass Piping Set HRS-BP004 for Models HRS-040, HRS050
Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024, HRS030; SMC recommends Bypass Piping Set HRS-BP004 for Models HRS-040, HRS050
Alarm code “AL28” (pump maintenance) will be activated every 20,000 hours (every 8000 hours for option “T” and the HRS050/060) of operation.
Consider requesting maintenance from a maintenance company.
We can recommend service providers if needed.
For the HRS012/018/024/030 option “T” (high-pressure pump) and the HRS050/060, after 8000 hours, alarm code “AL28” (pump maintenance) will be activated.
We recommend that you check for leaks and replace the mechanical seal at this time. Consider requesting maintenance from a maintenance company. We can recommend service providers if needed.
Note 1) These are the default settings of the HRS050. The operating settings can be changed by the user.
The default setting for alarm code “AL08” is stop operation for the HRS090 to 200.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: JM (J + M)
Please contact us for the latest version.sales@ocaire.com, FITTING *LQA, CONNECTORS, KQ ONE TOUCH FITTING, JM, KQ 10MM, 0.02277 lb
Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa, FITTING, REDUCER ELBOW, CONNECTORS, KQ2 FITTING, JM, KQ2 10MM, .01227 lb
Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa, FITTING, PLUG-IN ELBOW, CONNECTORS, KQ2 FITTING, JM, KQ2 10MM, 0.02224 lb