For male thread When in the locked state, do not apply a load accompanied by an impact shock, strong vibration, turning force, etc. 30 Note that an external action, such as an impacting load, strong vibration, or turning force, may damage the lock unit or reduce its life.
When ordering nuts as spare parts, size 4 and 5 are as shown below.
For male thread When in the locked state, do not apply a load accompanied by an impact shock, strong vibration, turning force, etc. 30 Note that an external action, such as an impacting load, strong vibration, or turning force, may damage the lock unit or reduce its life.
As a rule, turn the screw an additional 90 after tightening resistance is felt. FB 50 Stroke 66 67.5 109 109 117.5 117.5 121 141 51 Stroke or more 97.5 99 114 114 129 129 148 166 20 25 32 40 50 63 80 100 66 67.5 71.5 78 83 88 102.5 120 19 20 22 22 23 23 24 29 * Other dimensions are same as standard.
As a result, the inside of the bowl q is shut off from the outside air. Therefore, even if there is an accumulation of condensate in the bowl q, it will not drain out.
When designing an application, be sure to allow sufficient clearance for maintenance and inspections. x 1000 Auto switch operating range (mm) V(mm/s) = Time load applied (ms) In cases of high piston speed, the use of an auto switch (D-F5NT) with a built-in OFF delay timer (approx. 200ms) makes it possible to extend the load operating time. 4. Wiring should be kept as short as possible.
adjustment is required as shown in the chart below).
Also, applicable for use in an environment with water splashing such as food processing and car wash equipment, etc.
The Number of Insertions and Removals from Self-seal Fitting Caution qThe number of insertions and removals as a rough quide is as follows.
Use self-align fittings in the piping for an air-hydro cylinder. Do not use One-touch fittings in the piping for an air-hydro cylinder, as oil leakage may occur. 2. Use tubing materials such as hard nylon or copper for air-hydro cylinder piping.
When in the locked state, do not apply a load accompanied by an impact shock, strong vibration or turning force, etc. Use caution, because an external action such as an impacting load, strong vibration or turning force, may damage the locking mechanism or reduce its life. 2. Consider stopping accuracy and the amount of over-run when an intermediate stop is performed.
As a result, the inside of the bowl q is shut off from the outside air. Therefore, even if there is an accumulation of condensate in the bowl q, it will not drain out.
Top port An air cushion has been added to the compact guide cylinder to suppress vibration and noise at the stroke end. It can absorb nearly three times as much kinetic energy as a rubber bumper. Stroke Variations D1. Auto switch mounting 4.
In case of high piston speed, the operating time of the load can be extended by using an auto switch (D-F7NT) with built-in OFF delay timer (approx. 200ms). 4. Keep wiring as short as possible.
Cannot be used as an emergency shutoff valve, etc. This product is not designed for use as an emergency shutoff valve. If the valve is used in this type of system, other reliable safety assurance measures should also be adopted. 3.
As a result, the inside of the bowl q, is shut off from the outside air. Therefore, even if there is an accumulation of condensate in the bowl q, it will not drain out.
Remove the covers as shown in Figure (2) and make further adjustment by loosening the hexagon nut. 3. Various dimensions are indicated in Table (1). Never make an adjustment that exceeds the dimensions in the table, as it may cause an accident and/or damage.