SMC Corporation of America
Elite Part Number Search
Search Results "HRS400-AN-46-AK"

The following procedures are an example of how a test may be performed. It is intended as an overview and not as an all inclusive description. 1) Rotate the adjustment wheel counterclockwise (DECR) completely to relieve spring force.

It is illustrated with an arrow pointing towards the valve body or an "empty" triangle on the schematic. OUTLET (Downstream) is defined as a port connected to the region above the seat and below the diaphragm.

ASV How to Order AK 01 06 S AS 1 1F G 2 2 ASS Body size 1 2 3 4 Options M5 S None Sealant 1 8, 1 4 8 3 Applicable tube O.D.

www.stevenengineering.com I S E E I N S I D E F R O N T C O V E R F O R DETAILS OF YOUR LOCAL SALES OFFICE 2.96 ANCILLARY VALVES SERIES (N)AK AND (N)AQ CHECK VALVE SERIES (N)AK H O W T O O R D E R S E R I E S (N)AK S Y M B O L S High Flow Capacity Low Cracking Pressure: 0.2 Bar Port Sizes from 18 ~ 1 PT, NPT B O D Y S I Z E .P O RT . . .E F F E C T I V E S I Z E NPT . .O R I F I C E* NAK2000

It is illustrated with an arrow pointing towards the valve body or an "empty" triangle on the schematic. OUTLET (Downstream) is defined as a port connected to the region above the seat and below the diaphragm.

Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination D+K

Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: K (w/Fluid Fill Port)

Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F (G, with Rc-G Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination A+D+K

Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F (G, with Rc-G Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: A (w/Caster Adjuster foot)

Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: A (w/Caster Adjuster foot)

Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination A+K+M

Actuation is 90 degrees open to closed with a cutout window, on both sides of raised rectangular section, providing visual status of open or closed state. 260g 55 mm Direction of a raised rectangular section indicate open/close status Open Close Series AK CAT.NAS100-106A Series AK Diaphragm Valve Air Operated Type Manually Operated Type Series AK3542/AK4542 Series AK3652/AK4652 Body material

Do not apply excessive force or shock to the body or fittings with an impact tool. ASV 5. Sonic conductance (C) and critical pressure ratio (b) values for products are representative values. The speed controllers controlled flow values are with the needle fully open and free flow with the needle fully closed. It can cause damage or air leakage. AK 10.

It is illustrated with an arrow pointing towards the valve body or an "empty" triangle on the schematic. Outlet (Downstream) is defined as a port connected to the region above the seat and below the diaphragm. It is illustrated with an arrow pointing away from the valve body or a "filled" triangle on the schematic.

Note 2) For AS121FP AS-FPG/Stainless steel 304 AQ Release button color: Light blue Flow Rate and Effective Area ASV AS121FP-M5 4 AS221FP-01 AS421FP-04 AS221FP-02 AS321FP-03 Model AK 4 6 4 6 8 6 8 10 10 12 Tubing O.D.

AK ASS ASR Straight type Easily installed in pipe lines.

AS1001FG-04-X214 ASV AK Needle Valve/Flow Characteristics VCHC Note) The flow characteristics are representative values.

1 Speed Controller Adjustable by Flat Head Screwdriver with One-touch Fitting Series AS1F-D Elbow Type/Universal Type Flow adjustable by flat head screwdriver Prevention of an unnecessary manual operation Model Applicable tubing O.D.

Use an extension fitting included with the product for the combinations in the table below.