SMC Corporation of America
Elite Part Number Search
Search Results "ISE1L-T1-17C"

Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 16 (NPN Open Collector 2 Outputs, w/o Analog Output, 3 Rotation setting), Wiring Specification: CN (w/o Connector)

Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 19 (NPN Open Collector 1 Output, w/Analog Output, 200° Setting), Wiring Specification: L (Grommet Lead Wire 3m)

Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 17 (NPN Open Collector 2 Outputs, w/o Analog Output, 200° Setting)

Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 17 (NPN Open Collector 2 Outputs, w/o Analog Output, 200° Setting), Wiring Specification: L (Grommet Lead Wire 3m)

Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 55 (PNP Open Collector 1 Output, w/o Analog Output, 200° Setting), Wiring Specification: CL (Connector Style Lead Wire Length 3.0m)

Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 18 (NPN Open Collector 1 Output, w/Analog Output, 3 Rotation setting), Wiring Specification: CL (Connector Style Lead Wire Length 3.0m)

Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 16 (NPN Open Collector 2 Outputs, w/o Analog Output, 3 Rotation setting)

Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 55 (PNP Open Collector 1 Output, w/o Analog Output, 200° Setting), Wiring Specification: L (Grommet Lead Wire 3m)

Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 15 (NPN Open Collector 1 Output, w/o Analog Output, 200° Setting), Wiring Specification: C (Connector Style Lead Wire Length 0.6m)

Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 15 (NPN Open Collector 1 Output, w/o Analog Output, 200° Setting)

Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 14 (NPN Open Collector 1 Output, w/o Analog Output, 3 Rotation Setting)

(between live parts and case)50 M or more (at 500 VDC by megameter) between live parts and case01: R 8, M5 x 0.8 T1: NPTF 1/8, M5 x 0.8 00: ZM ejector mount type40 g (Including 0.6 m-Long lead wire)Oil-resistant vinyl cabtire code 3 cores, ?

ZPA-T1-B01 ZPA-T1-N01 ZPA-T1-T01 ZPA-T2-B01 ZPA-T2-N01 ZPA-T2-T01 ZPA-T2-B01 ZPA-T2-N01 ZPA-T2-T01 ZPA-T3-B01 ZPA-T3-N01 ZPA-T3-T01 ZPA-T3-B01 ZPA-T3-N01 ZPA-T3-T01 ZPA-T1-B8 ZPA-T1-B10 ZPA-T1-B8 ZPA-T1-B10 ZPA-T2-B8 ZPA-T2-B10 ZPA-T2-B12 ZPA-T2-B16 ZPA-T2-B8 ZPA-T2-B10 ZPA-T2-B12 ZPA-T2-B16 ZPA-T3-B12 ZPA-T3-B16 ZPA-T3-B12 ZPA-T3-B16 ZP40 ZP40 With three M3 bolts With three M3 bolts ZP50

ZPA-T1-B01 ZPA-T1-N01 ZPA-T1-T01 ZPA-T2-B01 ZPA-T2-N01 ZPA-T2-T01 ZPA-T2-B01 ZPA-T2-N01 ZPA-T2-T01 ZPA-T3-B01 ZPA-T3-N01 ZPA-T3-T01 ZPA-T3-B01 ZPA-T3-N01 ZPA-T3-T01 ZPA-T1-B8 ZPA-T1-B10 ZPA-T1-B8 ZPA-T1-B10 ZPA-T2-B8 ZPA-T2-B10 ZPA-T2-B12 ZPA-T2-B16 ZPA-T2-B8 ZPA-T2-B10 ZPA-T2-B12 ZPA-T2-B16 ZPA-T3-B12 ZPA-T3-B16 ZPA-T3-B12 ZPA-T3-B16 ZP40 ZP40 With three M3 bolts With three M3 bolts ZP50

Calculation example) T1 to T4 can be calculated as follows. L Speed: V [mm/s] a1 a2 T1 = V/a1 = 300/3000 = 0.1 [s], T3 = V/a2 = 300/3000 = 0.1 [s] Time T = T1 + T2 + T3 + T4 [s] [s] L 0.5 V (T1 + T3) V T1: Acceleration time and T3: Deceleration time can be obtained by the following equation.

Calculation example) T1 to T4 can be calculated as follows. L Speed: V [mm/s] a1 a2 T1 = V/a1 = 300/3000 = 0.1 [s], T3 = V/a2 = 300/3000 = 0.1 [s] Time [s] T = T1 + T2 + T3 + T4 [s] L 0.5 V (T1 + T3) V T1: Acceleration time and T3: Deceleration time can be obtained by the following equation.

L Speed: V [mm/s] Calculation example) T1 to T4 can be calculated as follows. a1 a2 Time [s] T1 = V/a1 = 300/3000 = 0.1 [s], T3 = V/a2 = 300/3000 = 0.1 [s] T = T1 + T2 + T3 + T4 [s] T1 T2 T3 T4 L 0.5 V (T1 + T3) V T1: Acceleration time and T3: Deceleration T2 = L : Stroke [mm] time can be obtained by the following equation. 200 0.5 300 (0.1 + 0.1) 300 (Operating condition) V : Speed

Change circulating fluid setting temperature.Set the pump output (option T1 only).