AS221FG-N02-11 33.9 43.2 63 18.5 29.5 41 15.2 17.9 8 3/8" 23 43.8 48.8 21.8 19 42.8 37.8 R 1/4 AS321FG-02-10 AS321FG-N02-07 27.8 39.3 67 21 31.8 43.3 18.5 13.2 10 1/4" 17 60 NPT 1/4 AS321FG-02-12 AS321FG-N02-09 19 21.8 29.5 41 69 22 32.8 44.3 20.9 15.2 12 5/16" 48.8 43.8 42.8 37.8 18.5 63 23 AS321FG-03-06 AS321FG-N02-11 31.8 43.3 55 17 27.8 39.3 12.8 17.9 6 3/8" 21 67 AS321FG-03-08 AS321FG-N03
AS121FM-U10/32-01 AS121FM-U10/32-03 AS121FM-U10/32-05 AS121FM-U10/32-07 AS221FM-N01-01 AS221FM-N01-03 AS221FM-N01-05 AS221FM-N01-07 AS221FM-N01-09 AS221FM-N02-03 AS221FM-N02-05 AS221FM-N02-07 AS221FM-N02-09 AS221FM-N02-11 1/8" 5/32" 3/16" 1/4" 1/8" 5/32" 3/16" 1/4" 5/16" 5/32" 3/16" 1/4" 5/16" 3/8" 8.4 9.3 11.4 12 12.7 22.1 12.3 17.3 7 9.6 30.1 28.8 25.1 8 33.8 10-32 UNF 16.5 13.5 26.1 23.1
. 80 mA Residual voltage 1 V or less T: Analogue output 1 to 5 V Output impedance 1 k V: Analogue output 4 to 20 mA Max. load impedance Power supply voltage 12 V: 300 Power supply voltage 24 V: 600 Min. load impedance 50 -V/-T (Auto-shift input mode) With auto-shift switch output PNP open collector output type 2 output Max. 80 mA Residual voltage 1 V or less -A NPN 2 output type Max. 28
For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V] x 1% = 0.04[V]) The maximum measuring range or change in analogue output over the maximum measurement range. F.S. (Full span, Full scale) H Hysteresis The difference between ON and OFF points used to prevent chattering. Hysteresis can be effective in avoiding the effects of pulsation.
Panel cut dimension 2 x 3.2 16.5 14.5 11 8.2 20 2 x 3.2 2 x 3.2 M3 thread hole 8.2 8.2 P U P S U H S H L O L C O K C K R V R S W V X S W T 19 T X 19 L2=50+T+X L2=50+T+X L1=50+R+V 14 L1=50+R+V 14 Pressure gauge (Accessory) 50 Pressure gauge (Accessory) 50 55 (at handle locked) 55 (at handle locked) IN OUT IN OUT 41.5 43.5 U Y 4 25 6 25 U Y 14 14 SMC SMC 2 x 3.2 2 x 3.2 42 42 IN side OUT side
NPN(1 )(15 V) PFM7--CNPN(1 )(420 mA) PFM7--DDC(+) OUT1 DC(-) Max.28 V80 mA 1 V C15 V 1 k D420 mA 600 50 NPN(1 ) PFM7--GDC(+) OUT1 DC(-) Max.28 V80 mA 1 V ()30 ms -18No.PF-OMJ0005CN-I PNP(2 ) PFM7--BDC(+) OUT1 OUT2 DC(-) Max.80 mA 1.5 V PNP(1 )(15 V) PFM7--EPNP(1 )(420 mA) PFM7--FDC(+) OUT1 DC(-) Max.80 mA 1.5 V E15 V 1 k F420 mA 600 50 PNP(1 ) PFM7--HDC(+) OUT1 DC(-) Max.80 mA
4 s d n e h t o B 6 A V 6 s d n e h t o B Dimensions/Auto feed tank 0 1 A V 0 1 s d n e h t o B 6 1 A V 6 1 s d n e h t o B 4 B V 4 e d i s e n O 6 B V 6 e d i s e n O 8 B V 8 e d i s e n O s n o i t a c i f i c e p S h c t i w S t a o l F n o i t p i r c s e D 2 ~ 1 0 1 4 S I y t i c a p a C W 5 1 : C D , A V 5 1 : C A e g a t l o V V 0 5 2 C D , V 0 0 1 C A e r u s s e r P f o o r P ) a
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket
M1 M2 Weight (g) ASV310F-N01-07 ASV310F-N01-09 ASV310F-N02-07 ASV310F-N02-09 ASV410F-N01-09 ASV410F-N01-11 ASV410F-N02-09 ASV410F-N02-11 ASV410F-N03-09 ASV410F-N03-11 ASV510F-N02-11 ASV510F-N02-13 ASV510F-N03-11 ASV510F-N03-13 ASV510F-N04-11 ASV510F-N04-13 73 73.8 73 73.8 83.1 85.2 83.1 85.2 83.1 85.2 90.2 91.9 90.2 91.9 90.2 91.9 17.2 19.3 17.2 19.3 19.3 23.3 19.3 23.3 19.3 23.3 23.3 26.5
The unnecessary output should remain unconnected. -27 NPN open collector 2 outputs Max. 30 V, 80 mA, Residual voltage 1 V or less -43 NPN open collector 1 output + PNP open collector 1 output Max. 30 V (NPN), 80 mA, Residual voltage 1 V or less A Pressure set value of switch output for NPN and PNP is common. -65 PNP open collector 1 output Max. 80 mA -67 PNP open collector 2 outputs Max.
Name Lead wire colour Function 1 DC(+) Brown 12 to 24 VDC 2 OUT2 White Switch output 2 3 DC(-) Blue 0 V 4 OUT1 Black Switch output 1 Used as IO-Link device No.
Name Lead wire colour Function 1 DC(+) Brown 12 to 24 VDC 2 OUT2 White Switch output 2 3 DC(-) Blue 0 V 4 OUT1 Black Switch output 1 Used as IO-Link device No.
Flame resistant PBT (UL standard V-0) Flame resistant type Cover Flame resistant CR Knob: 2 port valve: Gray 3 port valve: Blue 2/3 port valve: Red (Option) Cam ring POM POM Stem Flame resistant CR (UL standard V-0) For flame resistant type with cover only Spring guide 3(R) Exhaust 3(R) Exhaust Stainless steel Spring NBR Packing, O-ring, Valve 5-8-1 2 Series VHK How to Order 2 VHK R L 02S
Maximum load current 80 mA Maximum applied voltage 30 V (during NPN output) Switch output Internal voltage drop (Residual voltage) 1.5 V or less (Load current 80 mA) 1.5 ms or less (delay time available for anti-chattering function: Variable at 0 to 60 s/0.01 step) Delay time 1 Hysteresis Hysteresis mode Variable from 0 2 Window comparator mode Short circuit protection Provided Unit 3 MPa
ASP w"" P;lo' Ch.,k V,'v. efles Construction Parts list .QesCr;plian ' ''' fi1t~lal , . . . Parts list t f " ifote NO. f) 0 Body A PST Elbow body PST PST Knob 8 e Electroless nickel plated Pilot body Brass (1) SodyS Brass Electroless nickel plated 0 Electroless nickel plated Electroless nickel plated Brass Needle Eleclroless nickel plated 0 Needle guide Brass Guide Brass 0 (!)
11 One-touch Screw-in One-touch N01 N02 N02 Screw-in Screw-in Screw-in ZH15DA08 10 10 One-touch One-touch One-touch 08 03 10 One-touch Screw-in One-touch 02 03 03 Screw-in Screw-in Screw-in ZH15DA09 11 11 One-touch One-touch One-touch 09 N03 11 One-touch Screw-in One-touch N02 N03 N03 Screw-in Screw-in Screw-in ZH18DA10 12 12 One-touch One-touch One-touch 10 03 12 One-touch