Monitoring L Logical operation equipment L1 Logical operation equipment Input signal I Input equipment O Output equipment Input signal O1 Output equipment I1 Input equipment Output signal Output signal Monitoring Cross monitoring Monitoring L2 Logical operation equipment Input signal I2 Input equipment O2 Output equipment OTE Output of test result TE Testing equipment Output signal Output
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE76G (0 to 5 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE78G (0 to 16 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE75G (0 to 2 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE77G (0 to 10 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Type: Pressure Switch, Fluid Type: Air, Maximum Pressure Rating: 1MPa, Minimum Pressure Rating: 0kPa, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] Rc, Plumbing Thread Nominal: [1/4] 1/4, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating
Pressure Range: 0 to 5 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 16 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 2 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 10 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
(Example) For M3: L1 = 6 mm $The maximum dimension L2 is, as a rule, twice the thread size. (Example) For M3: L2 = 6 mm However, for M5 with T shaft, the maximum dimension L2 is 1.5 times the thread size.
M H L2 L1 A E M LQ1L12-M LQ1L11-M 3 4 11.5 1/8 11.5 10 15.5 18 1/8" R (NPT) Port size Class 1 LQ1L43-M LQ1L42-M LQ1L41-M LQ1L36-M LQ1L35-M LQ1L34-M LQ1L33-M LQ1L32-M LQ1L31-M LQ1L24-M LQ1L23-M LQ1L22-M LQ1L21-M 4 6 4 6 1/8" L1 16.5 14 14.5 15 20.5 27 1/4" 10 L2 M 1/4" 6 8 (A) 23 17 20 20 26.5 35 1/4 10 H 6 8 3/8" (E) Class 2 to 5 12 10 12 3/8" 28 21 25 24 33 45 1/2" LQ1L44-M 10 M LQ1L54-
P=0 41 (1 2 Mounlin9 holes L2 0 1 4 ( 3 . 5 ) Tgpe 541,/ Sitle Ported , r r ' : , a M Type Plug Connector(M) 11YY3,13-941-g"-'s;i.;l-M3 L Type Plug Connector(L) 0.1413.5) Dia.
P=0 41 (1 2 Mounlin9 holes L2 0 1 4 ( 3 . 5 ) Tgpe 541,/ Sitle Ported , r r ' : , a M Type Plug Connector(M) 11YY3,13-941-g"-'s;i.;l-M3 L Type Plug Connector(L) 0.1413.5) Dia.
Kl Ml Hl Dl MS Tl 2.1-32
Series KS/KX Male connector: KSH (Standard) Tube O.D. (mm) Connection thread R(PT) Min. hole dia. Effective area (mm2) Nylon Urethane
B L2 1 = W/Wmax = 1/7 = 0.14 L3 C 2. Static moment Mr = W x 9.8 (L3 + C) Examine Mr. (Mp, My values do not apply to this example.)
San=a1+a2+a31 3.11-10 Air Slide Table Series MXS Allowable load: W (N) Fig.1 Overhang: Ln (mm), Correction value for moment center distance An (mm) Fig.2 Pitch moment Yaw moment Roll moment W My Mp Mr W W W Static moment Dynamic moment L1 A1 L3 A5 L2 A3 CL W Mp Mr My W W MLGC L3 A6 W L1 A2 L2 A4 CNA W Mey Mep CB L2 A4 CV/MVG A2 L3 Work mounting coefficient: K Fig.3 CXW Table mounting CXS
Yes 100 V 24 V 12 V A93 A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV Solid state switches marked with are produced upon receipt of order. 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 2-wire 12 V 24 V Relay, PLC Grommet 3-wire (NPN) 3-wire (PNP) Diagnostic indication (2-color indication) 5 V, 12 V IC circuit 12 V 2-wire Lead wire length symbols: 0.5 mNil (Example) A93 3 mL