Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: None
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Calibration Certificate
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: None
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket B, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
Description Material 1 Body SCS14A (SUS 316) 2 Needle SUS316 L4 3 Lock nut SUS316 4 Valve SUS316 5 Valve guide SUS316, NBR for low temperature L2 L3 6 Spring SUS316 7 Bolt SUS316 8 O-ring NBR for low temperature L5 9 O-ring NBR for low temperature Model Port size D H L1 L2 L3 L4 Note) L5 Mass g MAX. MIN.
Light Assembly For 110 VAC: 1530118-1 220 VAC: 1530118-2 24 VDC: 1530118-5 Able to convert into L1, L2, L5 by changing each light assembly. 16-9-4
133-51 0.91 (231 0.47 (121 0.81 i20.5) 0.39 (10) Millimeters in Parentheses Millimeters in Parontheses NVM220-N02-08 230-N02-08 NVM220-N02-07 230-N02-07 Panel Mounling Panel Mounting F O F ' 1 2 3 s l b s ( 5 6 k 9 ) P T 0 138 in (3 5mm) o,T 0 079 in (2mm) T T 0 216 in (5 5mm) F O F ' 2 6 5 l b s , ( 1 2 k g ) T T 60" '75 PSIG (5 Kgf/cm2) '75 PSIG (5 Kgf/cm2) A B c D E F G A B c D E F G
133-51 0.91 (231 0.47 (121 0.81 i20.5) 0.39 (10) Millimeters in Parentheses Millimeters in Parontheses NVM220-N02-08 230-N02-08 NVM220-N02-07 230-N02-07 Panel Mounling Panel Mounting F O F ' 1 2 3 s l b s ( 5 6 k 9 ) P T 0 138 in (3 5mm) o,T 0 079 in (2mm) T T 0 216 in (5 5mm) F O F ' 2 6 5 l b s , ( 1 2 k g ) T T 60" '75 PSIG (5 Kgf/cm2) '75 PSIG (5 Kgf/cm2) A B c D E F G A B c D E F G
www.stevenengineering.com I 5.16 AIR PREPARATION MODULAR TYPE ACCESSORIES END BLOCK ADAPTOR Port Sizes: M5 ~ 1Rc Allows for easy installation and maintenance H O W T O O R D E R P I P I N G A D A P T O R E10-M5 1000 S E R I E S E20-N01 2000 S E R I E S E20-N02 2000 S E R I E S E20-N03 2000 S E R I E S E30-N02 3000 S E R I E S E30-N03 3000 S E R I E S E30-N04 3000 S E R I E S E40-N03 4000
: 48.9 Atmospheric vent port 02 4 x 2.6 Depth 7 or less 20 30 25 8.5 11 R1/4 M5 x 0.8 Thread depth 5 4.2 N02 30 20 NPT1/4 17 Piping port 02: R1/4 N02: NPT1/4 2.5 If there is a possibility that the atmospheric vent port of the switch will be exposed to water or dust, insert a tube into the atmospheric vent port and route the other end of the tube to a safe place away from water or dust. *
PSE56--28 Current output type 4 to 20 mA Allowable load impedance 500 or less (at 24 VDC) 100 or less (at 12 VDC) Brown LINE(+) Brown DC(+) Load Main circuit Main circuit (Analog output) 1 k Black OUT 12 to 24 VDC + 12 to 24 VDC + Load Blue LINE() Blue DC() Load Install the load either on the LINE (+) or LINE () side.
VBA10A-N02 VBA10A-T02 : when -Z VBA43A-N04 VBA43A-T04 : when -Z G27-20-01 G27-P20-01-X30 AN20-N02 VBA20A-N03 VBA20A-T03 : when -Z VBA40A-N04 VBA40A-T04 : when -Z VBA22A-N03 VBA22A-T03 : when -Z VBA42A-N04 VBA42A-T04 : when -Z VBA11A-N02 VBA11A-T02 : when -Z Model ITVH Description ITVX Pressure gauge : when Nil Pressure gauge : when -Z Note 4) G36-10-N01 G36-P10-N01-X30 AN30-N03 ANA1-N03
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)