(double solenoid) (24VDC) SQ2230D-5-C8 (3 sets) Blanking plate SSQ2000-10A-3 (1 set) Stations 1 2 3 4 5 6 7 8 U side 3m SSQ2000-10A-3 SQ2330-5-C8 SQ2230D-5-C8 SQ2230D-5-C8 SQ2230D-5-C8 SQ2130-5-C8 SQ2130-5-C8 SQ2130-5-C8 D-sub connector cable AXT100-DS25-030 D side Cylinder port fitting C8: 8 One-touch fitting Manifold base (8 stations) SS5Q23-08FD2-D F kit (D-sub connector kit) SS5Q23-08FD2
Bore size (mm) Auto switch model 20 25 32 40 50 63 80 100 D-C7/C8 Mounting procedure for clevis Follow the procedures below when mounting a pivot bracket on the clevis style.
b 0.26 0.20 0.22 0.19 b 0.35 0.18 0.21 0.18 C6 C8 C10 C12 C8 C10 C12 C12 10-SS5V1-10 10-SS5V2-10 10-SS5V3-10 10-SS5V4-10 Note) The values are for individually operated 2 position type manifold bases with 5 stations.
C6 (6 Onetouch fitting) C8 (8 Onetouch fitting) Rc(PT)1/8 C6 (6 One-touch fitting) C8 (8 One-touch fitting) Port size A, B port Rc(PT)1/8 Rc(PT)1/8: 11 (0.6) C6: 8.6 (0.48) C8: 9.9 (0.55) Body ported SYJ7l2l __ __ __ (1) Valve effective area mm2(Cv) Base mounted SYJ7l4l __ 11.9 (0.66) 9.5 (0.53) C6: 8.5 (0.47) C8: 9.7 (0.54) __ Note 1) Value for a single solenoid 2 position valve mounted
fitting assembly VQC 1/2 C8: 8 One-touch fitting assembly C6: 6 One-touch fitting assembly 2 x Rc 1/8, 1/4, C6, C8 23 P = 22 L1 L2 L3 ( 9.5) ( 9.5) 80 39.5 (For C6, C8) (For C6, C8) (For C6, C8) ( 9.5) VQC 4/5 DIN rail clamp screw 2 x M4 mounting hole 4.5 2 x M6 mounting hole VQZ IN IN IN IN 37.5 5.5 SQ (5) 69.5 (40) 6.5 58 10.5 80 Residual pressure release manual override VFS (For C6, C8
C6: One-touch fitting assembly for 6 B B B 4 2-Rc 1/8, 1/4, C6, C8 C6: One-touch fitting assembly for 6 C8: One-touch fitting assembly for 8 VQD 2 A C8: One-touch fitting assembly for 8 B 23 P = 22 L1 L2 L3 (For C6, C8) ( 9.5) DIN rail clamp screw 80 ( 9.5) 2-M4 mounting hole (For C6, C8) (For C6, C8) 4.5 2-M6 mounting hole IN IN IN IN 5.5 80 6.5 (40) 69.5 58 37.5 39.5 Residual pressure
Manifold Specifications SV1000 SV2000 SV3000 SV4000 Applicable series Manifold type 1 (P: SUP)/3, 5 (E: EXH) type Valve stations (maximum) Max. number of solenoids Tie-rod base manifold Common SUP, EXH 20 stations 32 points 1(P), 3/5(E) port C8, N9 C3, C4, C6 N1, N3, N7 C10, N11 C4, C6, C8 N3, N7, N9 C12, N11 C6, C8, C10 N7, N9, N11 C12, N11, 03 C8, C10, C12 N9, N11, 02, 03 Port size 4(A)
1/8 C6 C8 1/8 1/8 C6 C8 Body ported for internal pilot Base mounted for internal pilot 10-SS5YJ7-20 10-SYJ723 10-SS5YJ7-21 10-SS5YJ7-40 10-SS5YJ7-41 10-SS5YJ7-42-C6 10-SS5YJ7-42-C8 10-SYJ743 Note) Value at manifold base mounted, 2 position single operating How to Order Manifold Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold
Refer to pages 2-5-40 to 2-5-43 for control unit.
for internal pilot Type 10-SS5YJ7-21 Type 10-SS5YJ7-40 Base mounted Type 10-SS5YJ7-41 10-SYJ743 for internal pilot Type 10-SS5YJ7-42-C6 Type 10-SS5YJ7-42-C8 Note) The values are for individually operated 2 position type manifold bases.
2.0 2.1 2.3 2.1 2.1 2.5 2.2 2.2 2.2 0.26 0.25 0.25 0.26 0.24 0.20 0.23 0.30 0.23 0.26 0.55 0.49 0.51 0.54 0.50 0.50 0.59 0.55 0.52 0.53 1/8 1/8 1/8 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/8 C6 C8 1/8 C6 C8 1/8 1/8 C6 C8 SS5YJ7-20 Body ported SYJ72 for internal pilot SS5YJ7-21 SS5YJ7-40 SS5YJ7-41 SS5YJ7-42-C6 SS5YJ7-42-C8 Base mounted SYJ74 for internal pilot Note) Value at manifold base mounted, 2
N9 Individual EXH spacer VVQ2000-R-1-C8 N9 EXH block plate VVQ2000-19A C8 (EXH port) 8 One-touch fitting C8 (SUP port) 8 One-touch fitting One set includes 2 pcs.
N9 Individual EXH spacer VVQ2000-R-1-C8 N9 EXH block plate VVQ2000-19A C8 (EXH port) 8 One-touch fitting C8 (SUP port) 8 One-touch fitting One set includes 2 pcs.
Axial foot 16 40 Mounting bracket weight Front flange 5 15 This basic weight includes weight of rod end nut.
(i) Side Entry Single Sub-base for use with the Base Mounted Valve (Type 40). (ii) 2-10 Station Type 20 Mmanifold for use with the Body Ported Valve (Type 20). (iii) 2-10 Station Type 40 Side Entry Manifold for use with the Base Mounted Valve (Type 40). (iv) 2 10 Station Type 40 Bottom Entry Manifold for use with the Base Mounted Valve (Type 40).
x 1.5 Up to 700 1/8 146 9 10 40 40 60 196 206 20 42.5 40 32 M26 x 1.5 Up to 1000 1/8 159 9 10 40 60 209 219 22 40 51 M32 x 2 53 Up to 1000 1/4 181 10 11 53 77 236.5 247 26.5 The dimension NA(42.5) is wider than dimension TX(40).
MGP MGPA12-150 MGP MGPA12-100 MGPA -200 32 40 MGPA -150 32 40 MGPA -100 32 40 MGPA -200 32 32 40 40 0.2 0.4 MGP MGPA12-75 MGPA12-75 MGPA -150 32 32 40 40 0.15 0.3 MGPA -100 32 32 40 40 0.1 0.2 MGPA12-50 MGPA12-50 MGPA -50 32 40 MGPA -50 32 32 40 40 0.05 0.1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area
0.50 0.32 [0.44] 0.41 0.56 [0.44] 1.8 C8 8 Onetouch fitting Single 4position dual 3 port 53-SY9 20-C8 1.5 N.C.
How to Order [Option] VV5Q 08 C8 1 4 F U1 CE-compliant Nil Q CE-compliant Note) CE-compliant: For DC only.
1/8 C6 C8 1/8 1/8 C6 C8 Type SS5YJ7-20 Body ported SYJ72 for internal pilot Type SS5YJ7-21 Type SS5YJ7-40 Base mounted Type SS5YJ7-41 SYJ74 for internal pilot Type SS5YJ7-42-C6 Type SS5YJ7-42-C8 Note) Value at manifold base mounted, 2 position single operating How to Order Manifold (Example) Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along