Without auto switch With auto switch Stroke range (mm) Bore size (mm) J K D L C E M I H P M5 x 0.8 A A B F 5.5 Q 11.5 B P F Q 5 10 to 50 75, 100 5 to 50 75, 100 10 to 50 75, 100 30 23 32 40 M8 x 1.25 4.5 33 7.5 Rc 1/8 14 10.5 16 7 13 45 34 60 Rc 1/8 10.5 7.5 40 36.5 46.5 38.5 48.5 33 29.5 39.5 30.5 40.5 40 Rc 1/8 46.5 39.5 M8 x 1.25 5 8 Rc 1/8 14 11 16 7 13 52 40 69 11 8 M10 x 1.5 50 Rc 1
the workpiece will not drop are F F mg 2 x F > mg Number of fingers Gripping force at least 10 to 20 times the workpiece weight The 10 to 20 times or more of the workpiece weight recommended by SMC is calculated with a safety margin of a = 4, which allows for impacts that occur during normal transportation, etc. and therefore, When = 0.2 When = 0.1 mg F > 2 x mg F = x 4 2 x 0.2 mg F =
the workpiece will not drop are F F mg 2 x F > mg Number of fingers Gripping force at least 10 to 20 times the workpiece weight The 10 to 20 times or more of the workpiece weight recommended by SMC is calculated with a safety margin of a = 4, which allows for impacts that occur during normal transportation, etc. and therefore, When = 0.2 When = 0.1 mg F > 2 x mg F = x 4 2 x 0.2 mg F =
11 6.4 115 84 44.5 303 264 43 110 282 98 96 70 50 3.3 318 20 11 11 6.4 117.5 84 44.5 279 45 110 292 98 101 70 50 3.3 318 20 11 117.5 44.5 11 6.4 84 280 46 110 297 Note 1) For AC20 only, the position of the pressure gauge is above the center of the piping.
A (F) Note 1) Refer to p.4.0-11 "Applicable Fluid Check List" for detail of a special fluid out of the standard and the option specifications. The standard product and the option "D" have application of greace on the armature. R P C.O.
end) 14 6.5 F 4-M5 x 0.8 thread depth 7 49 3.5 1 14.5 28 24.5 24.5 29 24 58 Retraction end adjuster 6 N-M5 x 0.8 thread depth 6 11 5.5 Adjuster at extension end 5H9 depth 5 +0.030 0 36.5 (Adjuster at extension end) Bottom view of MXQ16L-50 1 11 5.5 11 12 I J 5.5 3 11 2-M5 x 0.8 thread depth 8 Operating port 2-M5 x 0.8 5H9 depth 5 +0.030 0 Max. 12 (Retraction end adjuster) 13 35 45 HA GA
AMF150C AMF-EL150 AMF-EL150-F AMF250C AMF-EL250 AMF-EL250-F AMF350C AMF-EL350 AMF-EL350-F AMF550C AMF-EL550 AMF-EL550-F AMF650 AMF-EL650 AMF850 AMF-EL850 Except option F For option F Element assembly Glass fiber, others AMF-EL450 AMF-EL450-F 4 Industrial Filters Replacement Procedure Actuators Modular F.R.L.
Fittings & Tubing Air Cylinders Rotary Actuators NDh8 NDh8 Section Y detail GA GC Y YY GA GC Mounting nut Relief port 2 x M5 x 0.8 Section YY detail NN NN MM Rod end nut Piping port 2 x M5 x 0.8 MM C D D B 0 0.3 NA H A F B 0 0.3 F NA S + Stroke A Z + 2 x Stroke H + Stroke M12 x 1.0 M10 x 1.0 NN (mm) 16 10 15 15 18.3 15 20 17 8 8 5 5 11 11 28 28 20.5 20.5 D H Bore size B F MM NA GC GA C A
11 11 11 11 16 16 18.5 8 0 0 0 0 M8 x 1.25 M8 x 1.25 M10 x 1.25 M12 x 1.75 M12 x 1.75 M14 x 1.5 M14 x 1.5 M16 x 1.5 51 58 58 71 72 110 110 120 8 11 11 13 16 6 7 7 11 11 15 15 17 14 18 18 22 26 31 31 36 11 11 14 17 17 30 24 26 22 19 22 237 245 254 262 296 305 315 324 379.5 402.5 382 405 419 440 9-3-10 43 Series CL1 Lock-up Cylinder Double Acting, Single Rod Rod Side Flange Style (F)/Long
Pin description 1 DC (+) 2 Analog output Accumulated pulse output wiring examples 3 DC () 4 OUT1 4-I thread with depth J 40 Max. 30V 80 mA or less OUT1 Black Load H 0V Blue 50 msec PF2A7H--28 29(-M) A B C D E F G H I J Model Brown PF2A703H PF2A706H PF2A712H 55 160 40 92 67 55 Rc 1, NPT 1, G 1 36 M5 x 0.8 8 OUT1 80 mA Load Black 65 180 45 104 79 65 Rc 11/2, NPT 11/2, G 11/2 Rc 2, NPT 2, G
(WO): SYJ5120-WO-M5(-F) Approx. 300 (Lead wire length) Applicable cable O.D. 3.5 to 7 82.1 Max. 10 60.9 28.1 [35.1] 53.4 12.7 42.1 32.6 M8 x 1 15.1 39.2 [46.2] Approx. 300 (Lead wire length) Pg7 73 [75.2] (2.3) 63.2 [65.4] 83 72.1 3 58.2 3 64.7 3 3 42.2 19.5 19.5 19.5 19.5 11 11 11 11 2-2.6 (For mounting) 2-2.6 (For mounting) 2-2.6 (For mounting) 20 20 20 2-2.6 (For mounting) (2.3) (2.3)
depth 8 14 depth 10.5 17.5 depth 13.5 17.5 depth 13.5 5.5 5.5 5.5 5.5 6.6 9 11 11 11 0 0.052 0 0.062 0 0.062 0 0.062 0 0.074 28 35 35 43 59 10.5 15 16 23 Note 1) Dimensions other than above are the same as the standard double acting single rod type.
F Note) 1, 10, 11 are for a metal bowl with level gauge that comes with drain cock.
B H C C d d 10 Y-J010B 15.2 8 21 M4 x 0.7 CP95 SNJ-006B 16 Y-J016B 6 NTJ-006A 16.6 11 21 M5 x 0.8 M6 x 1.0 4 8 9.2 6 M3 x 0.5 2.4 5.5 6.4 SNJ-010B 10 NTJ-010A M8 x 1.0 4 11 12.7 10 M4 x 0.7 3.2 7 8.1 NDd9 NDH10 NX R1 U1 Part no.
-7-11 to 11-7-12 for dimensions.
-7-11 to 11-7-12 for dimensions.
kit F kit P kit J kit P kit J kit G kit 2 to 24 2 to 24 2 to 16 stations stations stations Note 1) Besides the above, F/P kit with different number of pins are available.
kit F kit P kit J kit P kit J kit G kit 2 to 24 2 to 24 2 to 16 stations stations stations Note 1) Besides the above, F/P kit with different number of pins are available.