/N.C.) 1500 mm 4(A) 2(B) 2000 mm A Note 2) 3000 mm 10 mm Semi-standard 5(EA) 3(EB) 1(P) Electrical entry 4-position dual 3 port valves (N.O./N.O.) 2(B) 4(A) Symbol Electrical entry B Note 2) L-type plug connector Pilot type Nil R L Internal pilot 5(EA) 3(EB) 1(P) 4-position dual 3 port valves (N.C./N.O.)
The unit conversion between SI and conventional units are as follows: Oscillation acceleration 100m/s2 = 10.1972G Pressure 1MPa = 10.1972kgf/cm2 Cylinder thrust/load 100N = 10.1972kgf Standard air: Symbol (ANR) Torque 1Nm = 10.1972kgfcm Temperature 20C {293K}, Air with Moment of inertia 1kgm2 = 10.1972kgcm/s2 an absolute pressure of 760 mmHg Kinetic energy 1J = 10.1972kgcm {101.3kPa}, and
Collision Speed (mm/s) 200 200 1500 200 1500 Max.
F(N) F(N) Stroke 105 15 9 110 115 14 120 8 125 130 13 140 150 7 12 175 5 200 11 0 1 2 Rotation angle Linear motion Number of Auto Switches Mounted 02 0S 0 S2 SS S0 1 Nil 2S 20 2 n2 nS n0 n Combinations of made-to-order products No. 1 to 4 are available. Please contact SMC for further information. 11-10-19
Altitude [m] q Upper limit of ambient temperature [C] w Cooling capacity coefficient Less than 1000 m 45 1.00 Less than 1500 m 42 0.85 Less than 2000 m 38 0.80 Less than 2500 m 35 0.75 Less than 3000 m 32 0.70 Handling Warning 15. In locations where strong impacts or vibrations occur 16.
Operating time 20 s 30 s HRZ 10 s Voltage HRZD 5 s Min. 2 s HRW 1 s 0.5 s dV dt HECR = Voltage increase ratio 0.2 s 0.1 s dV HEC 0.05 s 0.02 s Time HEB 0.01 s 100 125 200 300 500 400 600 700 1000 2000 3000 4000 1500 dt HED Current (% for chiller main breaker volume) < For option B [With earth leakage breaker]> 3.
How to order L/M connector assembly Lead wire length Positive common specifications For single solenoid: SX100 40 4S B port N.C A port N.O Plug position Actuation Nil 300 mm Plug Plug 6 600 mm For double solenoid: For 3 position SX100 40 4D 10 15 20 25 30 50 1000 mm Number of solenoids 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Single Negative common specifications For single solenoid: SX100
Without lead wire Nil 6 10 15 20 25 30 300 600 1 2 3 Blue (2) For 100 VAC For 200 VAC Another VAC 1000 1500 2000 2500 3000 Socket Hook Red (2) Gray (2) 4 Red: +, Black: For DC Note) When ordering a valve in which the length of the wire is more than 600 mm, be sure to indicate the model number of valve without connector and connector assembly. Ex.)
(Note) The value will be -1500 to 1500 kpulse/s when kpulse/ -9 s 9 inputting command pulse.
Operating time 20 s 30 s Voltage 10 s 5 s Min. 2 s dV dt 1 s = Voltage increase ratio 0.5 s dV 0.2 s 0.1 s Time 0.05 s 0.02 s dt 0.01 s 100 125 200 300 500 400 600 700 1000 2000 3000 4000 1500 < For option B [With earth leakage breaker]> 3. This product is installed with a breaker with the following operating characteristics.
To represent an AND function: OUTPUT = S1 AND S2 To represent a NAND function: OUTPUT = NOT (S1 AND S2) Very complex arrangements can also be coded in this manner. Options: AND, OR, NOT, XOR Inputs 1> 2> 3> 4> Output ON/OFF 6 1 PneuAlpha Function Blocks 6 6.2 The SET/RESET Block This block can act as either a SET or RESET latch upon receipt of a signal.
40 200 100 RJ2725L Impact mass m [kg] 80 Impact mass m [kg] Impact mass m [kg] 30 150 RJ2015L RJ1412L 60 RJ2725H 20 100 RJ2015H RJ1412H 40 10 50 20 RJ1410 0 0 0 0 500 1000 1500 2000 0 500 1000 1500 2000 0 500 1000 1500 Collision speed [mm/s] Collision speed [mm/s] Collision speed [mm/s] Type of Impact Impact of air cylinder actuation (Downward) Check Model Selection Step z to c prior
How to Order SY100 68 A Lead wire length Nil 300 mm 6 600 mm 10 15 20 25 30 50 1000 mm Caution 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Failure to meet IP65 performance may result if using alternative connectors than those shown above, or when insufficiently tightened.
pressure range (MPa) 0.15 to 0.7 Internal pilot Ambient and fluid temperature (C) Response time ms (at 0.5 MPa) Note 1) 10 to 50 (No freezing. ) 15 or less Max. operating frequency (Hz) 10 Non-locking push type, push-turn locking slotted type, push-turn locking lever type Manual override (Manual operation) Pilot exhaust method Lubrication Mounting orientation Impact/Vibration resistance (m/s2
Non-locking push type Manual override Lubrication Mounting orientation Shock/Vibration resistance (m/s2) (2) Not required Unrestricted 300/50 Dustproof Note 1) Based on dynamic performance test, JIS B 8374-1981.
DIN rail type, ACTUATOR, ELECTRIC, SLIDER, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, .00000 lb, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [kg] Note 2)Max. speed [mm/s]Max. acceleration/deceleration [mm/s2]Positioning repeatability [mm]Equivalent lead [mm]Impact/Vibration resistance [m/s2] Note 4)Actuation
railtype, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, 12.64901 lb, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [kg] Note 2)Max. speed [mm/s]Max. acceleration/deceleration [mm/s2]Positioning repeatability [mm]Equivalent lead [mm]Impact/Vibration resistance [m/s2] Note 4)Actuation typeGuide
DIN rail type, ACTUATOR, ELECTRIC, SLIDER, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, .00000 lb, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [kg] Note 2)Max. speed [mm/s]Max. acceleration/deceleration [mm/s2]Positioning repeatability [mm]Equivalent lead [mm]Impact/Vibration resistance [m/s2] Note 4)Actuation
DIN rail type, 40MM LE ELECTRIC ACTUATOR, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [kg] Note 2)Max. speed [mm/s]Max. acceleration/deceleration [mm/s2]Positioning repeatability [mm]Equivalent lead [mm]Impact/Vibration resistance [m/s2] Note 4)Actuation typeGuide
When equipped with a light, be careful not to damage the light with the cords lead wires. 10 15 20 25 30 50 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For DC SY3120-5LO-M5 SY100-30-4A-20 For AC SY3120-1LO-M5 SY100-30-1A-20 Precautions Plug in and pull out the connector vertically without tilting to one side.