SMC Corporation of America
Elite Part Number Search
Search Results "LEY16EC-50C"

The fluid and ambient temperatures are 0 to 50C. Since moisture in the fluid can freeze when used at 5C or below, causing damage and malfunction of switches, consider measures to prevent freezing. The installation of an air dryer is recommended to remove drainage and moisture from circuits.

SY30M--SY3 (R) 0 3 SY50M-SY5 (R) 0 3 SY70M-SY7 (R) 0 3 Interface regulator model Applicable valve model Note 2) Regulating port Set pressure range Maximum operating pressure Fluid Ambient and fluid temperature 1(P), 4(A), 2(B) 0.1 to 0.7 MPa 1.0 MPa Air 10 to 50C (No freezing) 75 69 93 87 Weight [g] Note 3) With pressure gauge Without pressure gauge 33(35) Note 4) 27(29) Note 4) (A)4 2(B)

Note 3) Solenoid valve: Max. 50C Note 4) Synthesized effective area with 2 position.

Compact size (Width: 15 mm) Low power consumption: 1.8 W DC Fluid Air 0.15 to 0.7 0.1 to 0.7 0.15 to 0.7 10 to 50C (No freezing.

(PF2A7H: 0 to 50C) 2% F.S. (15 to 35C) 5% F.S. (0 to 50C) Monitor unit 2% F.S. (15 to 35C) 5% F.S. (0 to 50C) 2% F .S. (15 to 35C) 5% F .S. (0 to 50C) 2% F.S. (15 to 35C) 5% F.S. (0 to 50C) 0.5% F.S. (0 to 50C) 1% F.S. (Fluid: Dry air) Analog output: 3% F.S. 1% F .S. (PF2A70, PF2A7H) 2% F .S. (PF2A71) 1% F.S. (Fluid: Dry air) Analog output: 5% F.S. Monitor unit 0.1% F.S.

Operate in an ambient temperature range between 0C and 50C. 3. Operate in an ambient humidity range between 35% to 85% (with no condensation).

Model ZR1-FX Vacuum to 0.5 MPa 5 to 50C 30 m PVF 0.1 kg Operating pressure range Operating temperature range Filtration efficiency Element Weight (With bracket) Note) If not operated within the specified range of pressure and temperature, trouble may be caused.

CCVS10-U1 Option Specifications Combined valve Control valve Stop valve, Skip valve Specifications Throttle valve Flow control valve Small flow Large flow Small flow Large flow Timid flow Small flow Large flow 0 to 0.7 MPa 0 to 0.7 MPa 0.3 to 0.7 MPa Operating pressure 0.3 to 0.7 MPa External pilot pressure 1.05 MPa Proof pressure 5 to 50C Ambient & Fluid temperature Turbine

10l/min 5 to 50l/min 20 to 200l/min 50 to 500l/min Flow rate measurement range Minimum setting unit 1% of maximum flow rate l/min, CFM x 10Accumulated flow l/min, CFM x 10Real-time flow rate Display units Note 1) l, ft x 10Operating pressure range Withstand pressure Pressure loss 0 to 0.5MPa 1.0MPa 10kPa (at 200l/min) 30kPa (at 500l/min) 3kPa (at 50l/min) 3kPa (at 100l/min) 0 to 9l 0 to 50C

Normally closed Normally open VNA01 VNA02 VNA03 Valve Double acting Pressure range Lubrication Temperature Style External pilot air 5C to 50C(Air operated: 60C) Note 1) No freezing Note 2) Lubrication is not allowed in case of seal material EPR.

Single acting, Single rod, Spring return/Spring extend Action Non-lube Type Air Fluid 1.05 MPa Proof pressure 0.7 MPa Maximum operating pressure 0.15 MPa Minimum operating pressure 10 to 50C (No freezing) Ambient and fluid temperature RE A B Rubber bumper Cushion Not required (Non-lube) Lubrication REC JIS Class 2 Thread tolerance + 1.0 0 Stroke length tolerance CX 10, 16 Applicable bore

Single acting, Single rod, Spring return/Spring extend Action Non-lube Type Air Fluid 1.05 MPa Proof pressure 0.7 MPa Maximum operating pressure 0.15 MPa Minimum operating pressure 10 to 50C (No freezing) Ambient and fluid temperature RE A B Rubber bumper Cushion Not required (Non-lube) Lubrication REC JIS Class 2 Thread tolerance + 1.0 0 Stroke length tolerance CX 10, 16 Applicable bore

CP96, profile design ISO cylinder with enclosed tie rods, is available in 6 bore sizes from ø32 to ø125mm.  High accuracy covers and tie rod nuts improve mounting accuracy and extend the cylinder life.  Increasing the precision of the bushing and piston rod, as well as reducing tolerances, has decreased the deflection of the piston rod.  Standard strokes range from 25 to 800mm.Double Acting

CP96, profile design ISO cylinder with enclosed tie rods, is available in 6 bore sizes from ø32 to ø125mm.  High accuracy covers and tie rod nuts improve mounting accuracy and extend the cylinder life.  Increasing the precision of the bushing and piston rod, as well as reducing tolerances, has decreased the deflection of the piston rod.  Standard strokes range from 25 to 800mm.Double Acting

CP96, profile design ISO cylinder with enclosed tie rods, is available in 6 bore sizes from ø32 to ø125mm.  High accuracy covers and tie rod nuts improve mounting accuracy and extend the cylinder life.  Increasing the precision of the bushing and piston rod, as well as reducing tolerances, has decreased the deflection of the piston rod.  Standard strokes range from 25 to 800mm.Double Acting

"Cylinder, CP96, TIE ROD CYLINDER W/PROFILE TUBE, N lb

"Cylinder, CP96, TIE ROD CYLINDER W/PROFILE TUBE, N lb

CP96, profile design ISO cylinder with enclosed tie rods, is available in 6 bore sizes from ø32 to ø125mm.  High accuracy covers and tie rod nuts improve mounting accuracy and extend the cylinder life.  Increasing the precision of the bushing and piston rod, as well as reducing tolerances, has decreased the deflection of the piston rod.  Standard strokes range from 25 to 800mm.Double Acting

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches