SMC Corporation of America
Elite Part Number Search
Search Results "LEY16RA-100C-R1"

Size: 16, Motor Mounting Position: Left, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 100mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting:

Series: Ball Screw Drive, Accuracy: Basic Type, Size: 25, Motor Mounting Position: Right Side Parallel, Motor: A [Servo Motor (24 VDC)], Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm, Stroke: 100mm, Motor Option: w/o Lock, Auto Switch Mounting Bracket: w/1 pc, Included, Grease Application: with, Positioning Pin Hole: Housing B, Bottom, Actuator Cable: Robotic Flexible

Bearing Type: Sliding Bearing, Stroke: 100mm, Motor Option: w/Motor Cover, Switch Rail Option: w/o Option, Actuator Cable Type: R [Robotic Cable (Flexible Cable)], Actuator Cable Length, m: 1.5, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector: -

Size: 25, Bearing Type: Ball Bushing Bearing, Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 100mm, Motor Option: with Motor Cover, Guide Option: w/o Guide, Actuator Cable Type: Robotic Cable - Flexible cable, Actuator Cable Length: 1.5m, Controller Type for (LEC, JXC): -, I/O Cable Length for LEC: -,

Size: 25, Bearing Type: Ball Bushing Bearing, Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 100mm, Motor Option: with Motor Cover, Guide Option: w/o Guide, Actuator Cable Type: Robotic Cable - Flexible cable, Actuator Cable Length: 1.5m, Controller Type for (LEC, JXC): -, I/O Cable Length for LEC: -,

Size: 25, Bearing Type: L (Ball Bushing Bearing), Motor Mounting Position: Top Mounting, Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Guide Option: w/o Option, Actuator Cable Type, Length: R1 (1.5m)

Size: 40, Motor Mounting Position: Top Mounting, Motor Type: Step Motor (Servo/24 VDC), Lead Screw: C (LEY16: 2.5mm; LEY25: 3mm; LEY32/40: 4mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female Rod End, Mounting: Ends Tapped (Standard), Actuator Cable Type: R (Robotic Cable, Flexible Cable), Cable Length: 1 (1.5m)

Size: 40, Motor Mounting Position: Top Mounting, Motor Type: Step Motor (Servo/24 VDC), Lead Screw: LEY16: 2.5mm; LEY25: 3mm; LEY32/40: 4mm, Stroke: 100mm, Motor Option: w/Motor Cover, Rod End Thread: Female Rod End, Mounting: Ends Tapped (Standard), Actuator Cable Type: Robotic Cable, Flexible Cable, Cable Length: 1.5m, Controller/Driver Type: -, I/O Cable Length: -, Protocol: -, Suffix:

High purity chemical valve, 3 port, Operating pressure: 0 ~ 0.5 MPa , Fluid temperature: 0 to 100C , Port sizes: 1/4, Threads: Rc, NPT FLUOROPOLYMER VALVES and REG. FLUOROPOLYMER, VALVE. VALVE. FLUOROPOLYMER. 0.22088 lb. 2I.

Although the variation in the operating range differs with the cylinder on which the auto switch is mounted, a temperature change of 100C will roughly result in the maximum of 20% reduction in the overall operation range.

Finger material Dust cover material DFinger material Action 20Action The packing class has been revised to adopt thermal proof materials for use at high temperature of up to 100C. Possible to select the auto switch mounting side.

Controller Specifications LC7R-K11A LC7R-K12A Model Regeneration method Heat exchange method based on resistance Regenerative resistance capacity 40W Regenerative operation voltage 180V 380V Regenerative absorption unit Regenerative voltage input mis-wiring protection Over current protection, Overheating protection (Normally closed, Radiator sensor OFF at 100C) Protective circuit To PLC,

Controller Specifications LC7R-K11A LC7R-K12A Model Regeneration method Heat exchange method based on resistance Regenerative resistance capacity 40W Regenerative operation voltage 180V 380V Regenerative absorption unit Regenerative voltage input mis-wiring protection Over current protection, Overheating protection (Normally closed, Radiator sensor OFF at 100C) Protective circuit To PLC,

Controller Specifications LC7R-K11A LC7R-K12A Model Regeneration method Heat exchange method based on resistance Regenerative resistance capacity 40W Regenerative operation voltage 180V 380V Regenerative absorption unit Regenerative voltage input mis-wiring protection Over current protection, Overheating protection (Normally closed, Radiator sensor OFF at 100C) Protective circuit To PLC,

Finger material Dust cover material DFinger material Action 20Action The packing class has been revised to adopt thermal proof materials for use at high temperature of up to 100C. Possible to select the auto switch mounting side.

The packing class has been revised to adopt heat resistant materials for using it at a high temperature of up to 100C.

Stations 2 to 8 stations Specifications Common SUP Individual OUT Individual EXH (from IR body) IR1000: Rc(PT) 1/4, IR2000: Rc(PT) 3/8 Ports IR1000: Rc(PT) 1/8, IR2000: Rc(PT) 1/4 L For low temp. environments T For high temp. environments Symbol Environment Set pressure Accessory (pressure gauge) 0.2MPa, 0.4MPa and 0.8MPa settings can be combined G33--01 (IR1000), G43--01 (IR2000) 5 to 100C

MHZ2 Thermal proof 2 Grooves for auto switch on both sides 4 MHZJ2 MHQ Cylinder bore X4 F MHK D 1 L 2 MHK 2 L D 1 F Cylinder bore X41 MHL2 Finger material Dust cover material Finger material MHR Action Action The packing class has been revised to adopt thermal proof materials for use at high temperature of up to 100C. MHK Possible to select the auto switch mounting side.

The packing class has been revised to adopt thermal proof materials for using it at high temperature of up to 100C.

Locking (Maximum Static Load) 125 140 160 Bore size (mm) 8.4 {859} 10.5 {1077} 13.8 {1407} Holding force KN {kgf} Be sure to make cylinder selections in accordance with the method given on page 30. 2 Series CLS Mounting Brackets/Part Numbers Rod Boot Materials 125 140 160 Bore size (mm) Max. ambient temperature Nil Material J Foot type Note 1) 60C Nylon tarpaulin CS1-L12 CS1-L14 CS1-L16 100C