SMC Corporation of America
Elite Part Number Search
Search Results "LEY32B-500B-R36P1D-X5"

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 500mm, Motor Option: w/Lock, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: JXCP1, PROFINET, I/O Cable Length for LEC: Without Cable, Controller Mounting

LEY -X5 Select a suitable actuator by the relationship between the allowable work load and speed, and the allowable speed of each stroke.

Symbol Specifications/Description MHR -X4 -X5 -X50 -X53 -X56 -X63 -X79 Heat resistance (100C) Auto switch installation examples and mounting positions Auto switch hysteresis Auto switch mounting Protrusion of auto switch from edge of body Fluororubber seal MHK Without magnet MHS EPDM seal/Fluorine grease Axial ported MHC Fluorine grease Grease for food MHT MHY MHW -X MRHQ MA D545 Series MHS2

D2012-7-65 65 Series MHS Made to Order Specifications: 1 Oil Resistant Specifications -X5 MHS MHSJ3 MHSH3 MHSL3 D DF DF D Solid state switch Bore size X5 Seals are changed to an oil resistant material for use in environments where there is exposure to cutting oil, etc.

Symbol Fluororubber Seal -X5 2 How to Order Please contact SMC, since the type of chemical and the operating temperature may not allow the use of this product. Since the standard type magnet is built-in, please contact SMC for the products adaptability to the operating environment. Standard model no.

Symbol -X5 3 Non-standard Angle Adjustment Range MRQ Mounting Stroke Cushion Auto switch Rotating angle S X X5 32 40 Angle adjustment range For rotating angle, fill in either A (90 type) or B (180 type).

Symbol Mounting screw dimensions (Distinction of stroke) Non-standard angle adjustment range -X5 3 Stroke Cushion Mounting style Rotation angle Auto switch MRQ S X X5 32 40 Non-standard angle adjustment range +5 -95 The standard angle adjustment range of 5(one side) is changed to in this type.

MHC Symbol Specifications/Description Heat resistance (100C) Fluororubber seal Opening direction spring assist EPDM seal/Fluorine grease Axial ported type Fluorine grease Finger: Side tapped mounting Finger: Through-hole mounting Dust cover adhesion Dust cover adhesion (Finger part only) Dust cover caulking Dust cover caulking (Finger part only) Grease for food -X4 -X5 -X12 -X53 -X56 -X63

) (1) Connection diagram (a) FX-32MT (FX-1PG) Driver Servo amplifier FX-32MT L Power supply CN1 N 24VDC COM 46 DOCOM PC-RUN RUN ABS transmission data bit 0/Completion of positioning 3.3k X0 ABSB0 22 ABS transmission data bit 1/Zero speed detection X1 ABSB1 23 ABS transmission data ready/Torque limit control speed X2 ABST 25 Alarm X3 ALM 48 Alarm reset Servo ready X4 RD 49 Emergency stop X5

LEFS v 11-LEFS v 25A-LEFS v LEFB v LEL v LEM v LEY v 25A-LEY v LEY-X5/X7 v LEYG v LES v LESH v LEPY v LEPS v LER v LEHZ v LEHZJ v LEHF v LEHS v High performance step motor (24 VDC) LEFS v LEFS v 11-LEFS v 25A-LEFS v LEFB v LEY v LEY-X5/X7 v LEYG v LES v LESH v LEPY v LEPS v Servo motor (24 VDC) Step motor (Incremental) LEFS v

MRQ Mounting Stroke Cushion Auto switch Rotating angle S X X5 32 40 Angle adjustment range For rotating angle, fill in either A (90 type) or B (180 type).

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65

Size: 25, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: B (LEY25, 6; LEY32, 8), Stroke: 150mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 3m, Controller Type (LEC, JXC): 6P (LECA6, Step Data Input Type, PNP), I/O Cable Length for LEC: 1 (1.5m), Controller Mounting: D (DIN Rail Mounting),

Size: 32, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: C (LEY25, 3; LEY32, 4), Stroke: 50mm, Motor: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 3m, Controller Type (LEC, JXC): 6P (LECA6, Step Data Input Type, PNP), I/O Cable Length for LEC: 1 (1.5m), Controller Mounting: D (DIN Rail Mounting),

Size: 25, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: A (LEY25, 12; LEY32, 16), Stroke: 200mm, Motor: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 3m, Controller Type (LEC, JXC): 6P (LECA6, Step Data Input Type, PNP), I/O Cable Length for LEC: 1 (1.5m), Controller Mounting: D (DIN Rail Mounting

Size: 25, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: C (LEY25, 3; LEY32, 4), Stroke: 50mm, Motor: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 3m, Controller Type (LEC, JXC): 6P (LECA6, Step Data Input Type, PNP), I/O Cable Length for LEC: 1 (1.5m), Controller Mounting: D (DIN Rail Mounting

Size: 25, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: A (LEY25, 12; LEY32, 16), Stroke: 200mm, Motor: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 3m, Controller Type (LEC, JXC): 6P (LECA6, Step Data Input Type, PNP), I/O Cable Length for LEC: 1 (1.5m), Controller Mounting: D (DIN Rail Mounting

Size: 25, Motor Mounting: Top Mounting Position, Motor Type: A (Servo Motor, 24 VDC), Lead: C (LEY25, 3; LEY32, 4), Stroke: 50mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 3m, Controller Type (LEC, JXC): 6P (LECA6, Step Data Input Type, PNP), I/O Cable Length for LEC: 1 (1.5m), Controller Mounting: D (DIN Rail Mounting

Size: 32, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: C (LEY25, 3; LEY32, 4), Stroke: 500mm, Motor: B (w/Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped (Standard), Actuator Cable Length: 3m, Controller Type (LEC, JXC): 6P (LECA6, Step Data Input Type, PNP), I/O Cable Length for LEC: 1 (1.5m), Controller Mounting