Rated Flow Range: 3 (5 to 200 L/min), Output Specifications: B (OUT 1: PNP; OUT 2: PNP; Integrated Display Type), Port Size: 8 (1; Applicable to LFE3), Thread: N (NPT), Option: Lead Wire w/M12 Connector; L/min Unit Specification, Insulation Type: Z (Piping Port is Insulated with the Power Supply), Piping Connection: X8 (Stainless Steel 304)
Rated Flow Range: 3 (5 to 200 L/min), Output Specifications: F (OUT 1: PNP; OUT 2: Analog 4 to 20 mA; Integrated Display Type), Port Size: 8 (1; Applicable to LFE3), Thread: N (NPT), Option: 2 (Lead Wire w/M12 Connector; Bracket; L/min Unit Specification), Insulation Type: Z (Piping Port is Insulated with the Power Supply), Piping Connection: X8 (Stainless Steel 304)
Rated Flow Range: 3 (5 to 200 L/min), Output Specifications: F (OUT 1: PNP; OUT 2: Analog 4 to 20 mA; Integrated Display Type), Port Size: 8 (1; Applicable to LFE3), Thread: N (NPT), Option: 4 (Lead Wire w/M12 Connector; gal/min Unit Specification), Insulation Type: Z (Piping Port is Insulated with the Power Supply), Piping Connection: X8 (Stainless Steel 304)
Rated Flow Range: 1 (0.5 to 20 L/min), Output Specifications: A (OUT 1: NPN; OUT 2: NPN; Integrated Display Type), Port Size: 4 (1/2; Applicable to LFE1), Thread: Rc, Option: Lead Wire w/M12 Connector; L/min Unit Specification, Insulation Type: Z (Piping Port is Insulated with the Power Supply), Piping Connection: X8 (Stainless Steel 304)
Rated Flow Range: 1 (0.5 to 20 L/min), Output Specifications: F (OUT 1: PNP; OUT 2: Analog 4 to 20 mA; Integrated Display Type), Port Size: 3 (3/8; Applicable to LFE1), Thread: N (NPT), Option: Lead Wire w/M12 Connector; L/min Unit Specification, Insulation Type: Z (Piping Port is Insulated with the Power Supply), Piping Connection: X8 (Stainless Steel 304)
Rated Flow Range: 2 (2.5 to 100 L/min), Output Specifications: D (OUT 1: NPN; OUT 2: Analog 4 to 20 mA; Integrated Display Type), Port Size: 6 (3/4; Applicable to LFE2), Thread: N (NPT), Option: 1 (L/min Unit Specification), Insulation Type: Z (Piping Port is Insulated with the Power Supply), Piping Connection: X8 (Stainless Steel 304)
LN, MN type: with 2 sockets.
M3 1 3 mn x g M1E mn x g mn x g M3E M3E x FE x Y FE FE Note) Regardless of the mounting orientation, dynamic moment is calculated using the formulas above.
Parker Swivel designator Quick Coupling Division 8145 Lewis Road Minneapolis, MN 55427 www.parker.com/quickcouplings D-5 Quick Coupling Division 8145 Lewis Road Minneapolis, MN 55427 www.parker.com/quickcouplings In-Line PS Series Swivels Housing O-Ring Back-up Ring Materials Of Construction Cap Screw Bearing Housing*:.Carbon Steel O-Ring Retaining Ring Shaft*:.Carbon Steel Plating:* .
Note 1) "LN" and "MN" include 2 sockets. Note 2) "D" and "DO" are not available for SY3000. Note 3) DIN43650C standard DIN terminal "Y" is also available.
: Without lead wire L P B: Locking slotted type E: Push-turn locking lever type H: 600 mm lead wire LN: Without lead wire LO: Without connector MO: Without connector L P 1 4632 LN and MN types are with 2 sockets.
Composite Center of Gravity Calculation m3 = mn = 0.88 + 4.35 + 0.795 + 0.5 = 6.525 kg 1 m3 X = x (mn x xn) 1 6.525 = (0.88 x 65 + 4.35 x 150 + 0.795 x 150 + 0.5 x 150) = 138.5 mm 1 m3 Y = x (mn x yn) 1 6.525 = (0.88 x 0 + 4.35 x 0 + 0.795 x 111 + 0.5 x 210) = 29.6 mm 1 m3 Z = x (mn x zn) 1 6.525 = (0.88 x 5 + 4.35 x 42.5 + 0.795 x 42.5 + 0.5 x 42.5) = 37.4 mm 4.
ME M 1 3 mn x g ME mn x g ME x FE x Y ME FE FE Note) Regardless of the mounting orientation, dynamic moment is calculated with the formulae above.
mm Round head combination screw Note) DC AC CEcompliant LN, MN type: With 2 sockets.
Nil None With vacuum switch Nil L Lead wire length 0.6 m Grommet type Electrical entry E Lead wire length 3 m Lead wire length 0.6 m Lead wire length 3 m Connector type G Grommet (Lead wire length 300 mm) Grommet (Lead wire length 600 mm) C CL CN H With lead wire L type plug connector Connector type L Without lead wire LN Without connector LO With lead wire M Without lead wire MN Without
"LN", "MN" types: with 2 sockets. For connector cable of M8 connector, refer to page 562.
MN MO Refer to Table (3) on page 13-3-35 regarding lead wire with connector part no.
: Without lead wire D: With connector LN: Without lead wire LO: Without connector MO: Without connector DO: Without connector H: Lead wire length 600 mm Type LN, MN: with 2 sockets.
: Without lead wire MO: Without connector V 6 VDC S 5 VDC R 3 VDC The LN or MN option includes 2 sockets for single solenoid valves and 3 sockets for double solenoid valves.
Wn Mass mn X-axis xn xa xb xc xd Y-axis yn ya yb yc yd Z-axis zn za zb zc zd X 1 mt = x (mn x xn)w Wa Wb Wc Wd ma mb mc md Y 1 mt = x (mn x yn)e D1 mt = x {mn x (A + zn)} r Z -X (n = a,b,c,d) Refer to the following sections 1 to 4 to calculate the center of gravity and the total load.