Size: 32, Motor Mounting Position: Top Mounting, Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: R5 (5m), Controller: C61 [Parallel Input (PNP)], Mounting: 8 (DIN Rail), I/O Cable: 1 (I/O Cable, 1.5m
Size: 32, Motor Mounting Position: Top Mounting, Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm, Motor Option: C (w/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: D (Double Clevis, Top Mounting), Actuator Cable Type, Length: RC (20m), Controller: CP1 (PROFINET), Mounting: 8 (DIN Rail)
Parallel I/O Type: 6 (PNP), Mounting: 8 (DIN Rail Mounting), Cable Connector: None, Actuator: LEY, Type: None, Body Size: 32, Bearing Type: None, Motor Mounting: Top Mounting, Lead: C (25: 3mm; 32, 40: 4mm), Stroke: 400mm
Parallel I/O Type: 6 (PNP), Mounting: 8 (DIN Rail Mounting), Cable Connector: 1 (1.5), Actuator: LEY, Type: None, Body Size: 32, Bearing Type: None, Motor Mounting: Top Mounting, Lead: C (25: 3mm; 32, 40: 4mm), Stroke: 50mm
Protocol: P (PROFINET®), Mounting: 7 (Screw Mounting), Cable Connector: None, Actuator: LEY, Body Size: 32, Motor Mounting: Top Mounting Type, Lead: C (16: 2.5mm; 25: 3mm; 12; 32/40: 4mm), Stroke: 200mm
Protocol: P (PROFINET®), Mounting: 7 (Screw Mounting), Cable Connector: None, Actuator: LEY, Body Size: 32, Motor Mounting: Top Mounting Type, Lead: C (16: 2.5mm; 25: 3mm; 12; 32/40: 4mm), Stroke: 150mm
Size: 32, Motor Mounting Position: Top Mounting, Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 200mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: D (Double Clevis, Top Mounting), Actuator Cable Type, Length: R3 (3m), Controller: CP1 (PROFINET), Mounting: 7 (Screw Mounting)
Size: 32, Motor Mounting Position: Top Mounting, Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 200mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: R5 (5m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 7 (Screw Mounting)
Size: 32, Motor Mounting Position: Top Mounting, Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 150mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: R5 (5m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 7 (Screw Mounting)
Series: LEFS (Ball Screw Drive), Accuracy: H (High Precision Type), Size: 25, Motor Mounting Position: R (Right Side Parallel), Motor Type: NZ (Mounting Type Z), Lead Screw: A (LEFS25, 12mm; LEFS32, 16mm; LEFS40, 20mm), Stroke: 300mm, Auto Switch Mounting Bracket: C [With 1 pc. (Included)]
Series: LEFS (Ball Screw Drive), Accuracy: Basic Type, Size: 32, Motor Mounting Position: R (Right Side Parallel), Motor Type: T7 (200W Output, Absolute Encoder), Lead: H (LEFS25, 20mm; LEFS32, 24mm; LEFS40, 30mm), Stroke: 300mm, Motor Option: w/o Option, Auto Switch Mounting Bracket: C (w/1pc, Included)
Cylinder Inner Diameter: D(φ): 32, Stroke: L(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead
Cylinder Inner Diameter: D(φ): 40, Stroke: L(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead
Cylinder Inner Diameter: D(φ): 50, Stroke: L(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead
Cylinder Inner Diameter: D(φ): 63, Stroke: L(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead
Cylinder Inner Diameter: D(φ): 80, Stroke: L(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead
Cylinder Inner Diameter: D(φ): 100, Stroke: L(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Without
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Without
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Without