3 Port Pilot Solenoid Valve 10-SYJ300 Note) CE-compliant: For DC only.
DC 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC Bracket Nil: Without bracket F: With bracket AC (50/60 Hz) 3 port 1 2 3 4 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, DC voltage is only available. Type of actuation Bracket 1 2 Normally closed Normally open (For manifold type 20, 20R) Bracket is mounted.
5 1/8 2 7/8 6 1 3/8 1-14 1 5/8 2 1/4 7/8 2 13/16 5 3/4 3 1/8 6 1 3/4 1 1/4-12 2 2.375 3/8 1 1/8 3 1/16 5 3/4 3 1/8 6 2 1 1/2-12 2 1/4 2.625 3/8 1 1/4 3 3/16 5 3/4 3 1/8 BORE E EE(NPT) F FB G J K R TF UF 1 1/2 2 3/8 3/8 5/16 2 1 1/4 1.43 2 3/4 3 3/8 2 2 1/2 3/8 3/8 3/8 2 1 5/16 1.84 3 3/8 4 1/8 2 1/2 3 3/8 3/8 3/8 2 1 1/8 5/16 2.19 3 7/8 4 5/8 3 1/4 3 3/4 1/2 5/8 7/16 2 1/4 1 1/4 3/8 2.76
XD Y LF P ZD 200 (2) 1 3/4-16 1 1/8 2.6 1 1/2 1/2 3/4 1/2 1/2 7/8 5/16-24 2.5 0.3 3/8 3/8 3/8 1.26 1.06 3/4 5/8 1/2 1 3/8 6 1/8 2.09 3 5/8 2.40 6 5/8 250 (2.5) 1 3/4-16 1 1/8 3.1 1 1/2 1/2 3/4 1/2 1/2 7/8 5/16-24 3 0 3/8 3/8 3/8 1.30 1.06 3/4 5/8 1/2 1 3/8 6 1/4 2.13 3 3/4 2.48 6 3/4 325 (3.25) 1 3/8 1-14 1 5/8 3.9 2 5/8 1 1/4 3/4 3/4 1 1/4 3/8-24 3.75 0 1/2 5/8 5/8 1.57 1.18 1 1/4 1 3/4
Rc 3/8 G 3/8 NPT 3/8 NPTF 3/8 Plug SV1000 SV2000 SV3000 SV4000 Since EX500 and EX120 type SI units are not included, order them separately.
8 @5 @3 w !6 !5 !1 !2 !0 Actuators !3 !
D side Stations 1 2 3 4 5 6 7 8 9 10 11 12 Description/Model (A) 4 (B) 2 2 position single 1 (P)3 (R2) 5 (R1) (A) 4 (B) 2 2 position double 1 (P)3 (R2) 5 (R1) (A) 4 (B) 2 3 position closed center Valves Options Port size (ports A, B) Enter in case of mixed sizes (CM). 1 (P)3 (R2) 5 (R1) (A) 4 (B) 2 3 position exhaust center 1 (P)3 (R2) 5 (R1) (A) 4 (B) 2 3 position pressure center 1 (P)3
(A) 4 (B) 2 Electrical entry B MN: Without lead wire MO: Without connector M: With lead wire (Length 300 mm) SOL.b SOL.a 3 (R) 5 (R) 1 (P) 4 position dual 3 port valve: N.C./N.O.
With light/surge voltage suppressor Z 2 B 1(P) 5(EA) 3(EB) 4 position dual 3 port valve: N.O./N.O. 2(B) 4(A) B Electrical entry MN: Without lead wire MO: Without connector M: With lead wire (Length 300 mm) 1(P) 5(EA) 3(EB) 4 position dual 3 port valve: N.C.
Nil A 4 (A) 4 (B) 2 S With surge voltage suppressor A 2 With light/Surge voltage suppressor B SOL.b SOL.a Z 3 (R) 5 (R) 1 (P) 4 position dual 3 port valve: N.O./N.O. (A) 4 (B) 2 Electrical entry B MN: Without lead wire MO: Without connector M: With lead wire (length 300mm) SOL.b SOL.a 3 (R) 5 (R) 1 (P) 4 position dual 3 port valve: N.C./N.O.
Flow Rate and Effective Area Flow direction symbols on body Meter-out type Meter-in type AS221F-01 AS231F-01 AS221F-02 AS231F-02 AS321F AS331F AS421F AS431F AS121F AS131F Models Symbol JIS symbol Metric sizes 3.2, 4, 6 3.2, 4 6 6 8 10 12 6, 8, 10 8, 10 4 10, 12 Tubing O.D. 1/8 5/32 3/16, 1/4 5/16 1/4, 5/16 3/8 1/8, 5/32 3/16, 1/4 Inch sizes 5/32 3/16 5/16 3/8 1/2 3/8 1/4 Flow rate l/min (
IC circuit Z80 No 3 wire (NPN) Y59A Y69A 5V 12V IC circuit 3 wire (PNP) Y7PV Y7P P. 60 2 wire Y59B Y69B 12V 3 wire (NPN) Y7NW Y7NWV Solid state switch 5V 12V IC circuit Diagnostic indication (2 color indicator) Relay, PLC Grommet Yes 24V 3 wire (PNP) Y7PW P. 61 Y7PWV Y7BW Y7BWV 12V Water resistant (2 color indicator) Y7BA 2 wire P. 62 Note 3) Magnetic field resistant (2 color indicator
Digital Display (3% digit LCO) . Predicted Failure Function . 2 Setpoint Use . High Accuracy O Do not subiect body to excessive exiernal force. O Plping tightening to.ques How To Older (Exampre) 3 4 ( 3 1 3 1 7 ( 1 5 1 5 2 0 ( 1 7 NZXl Nozzle Diameter (Same as Std.) Eiector Exhaust Type (Same as Std.)
121 5 147 21 48 8 58 3 138 6 NCA 170 26 59 9 66 3 158 8 170 26 9 3 72 66 158 10 DOther dimensions are the same as double acting, single rod, standard type.
115 150 45 167.5 97.5 132.5 185 69.5 L3 87 122 157 52 174.5 104.5 139.5 192 3 stns. x 1 2 stns. x 2 3 stns. x 2 2 stns. + 3 stns. x 2 2 stns. x 1 3 stns. x 3 2 stns. + 3 stns. 2 stns. x 2 + 3 stns. 2 stns. x 2 + 3 stns. x 2 Manifold composition Note) Manifold bases are composed by connecting 2 station and 3 station bases.
How To Order: Valve Port size : Without sub-plate Body ported SYJ3 2 5 LZ 1 M3 3 Base mounted (4 Port) SYJ3 3 5 LZ 3 2 Base mounted (5 Port) (With gasket and screws) 2 SYJ3 4 LZ 3 5 M5 : With sub-plate Manual override Type of actuation : Non-locking push type 1 2 3 4 5 2 Position single solenoid 2 Position double solenoid 3 Position closed center 3 Position exhaust center 3 Position pressure