P, R port SX3000 (Metric size) With One-touch fitting for 8 (Inch size) With One-touch fittings for 5/16" P, R port SX5000 (Metric size) With One-touch fitting for 10 (Inch size) With One-touch fittings for 3/8" For D side r End block assembly L SX3000-53-1A SX5000-53-1A For U side (Metric size) SX5000-51-1A (Inch size) SX3000-51-15A SX5000-52-1A (Metric size) SX3000-51-1A (Inch size) SX3000
Proper Auto Switch Mounting Position/Applicable Cylinder Series: CDBG1-XC13 (mm) Auto Switch Mounting Height (mm) Lock position D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-F7/F79F D-J79/F7NT D-F7W/J79W/F7BA H (Head side) R (Rod side) W (Both sides) A B Note 2) A B A B Note 2) Auto switch model D-F7V D-F7WV D-F7BAV D-J79C D-A7 D-A80 D-A73C D-A80C D-A79W Bore size 20 +0 +12 +11 +0 +11 +12 25 +0.5 +11.5
switch Auto switch Ht Ht A A 32 B B L 9-6-20 21 Series MNB Cylinder with Lock Double Acting, Single Rod Proper Auto Switch Mounting Position D-F5W D-J59W D-F5 D-J5 D-F5BAL D-F59F D-Z7/Z80 D-Y59/Y69 D-Y7P/Y7PV D-Y7W, D-Y7WV D-Y7BAL D-A3 D-A44 D-G39 D-K39 D-A5 D-A6 D-A59W D-F5NTL D-P5DWL Bore size (mm) A B A B A B A B A B A B A B 32 1 3.5 1.5 4 0 0.5 9.5 12 4.5 7 2 4.5 0 0.5 CL 40 1 3.5 1.5
MLGC 100 5.5 7 6 7.5 2.5 4 14 15.5 9 10.5 6.5 8 2.5 4 CNG Auto Switch Mounting Height D-Z7/Z-80 D-Y59 D-Y7P D-Y7W D-F5, D-J5 D-F59F D-F5W, D-J59W D-F5BAL, D-F5NTL D-A3 D-G39 D-K39 MNB D-A5 D-A6 D-A59W D-Y69 D-Y7PV D-Y7WV Bore size D-A44 D-Y7BAL D-P5DWL (mm) CNA Ht Hs Ht Hs Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht 31 38 23 30 23 26.5 23 25.5 27.5 77 27.5 67 32.5 25 35 24.5 32 CNS 33 42 26 34 26
Thread 10.5 35.3 LJ1H20N PC LJ1H20SC LJ1S20SC 700 to 1000mm stroke 30 8 700 to 1200mm stroke 700 to 1200mm stroke 26 2 When mounting a coupling on the motor, mount it within the dimensional range shown on the left. 32 13 Coupling mounting dimensions2 Section AA (Housing interior) Series LJ1H S30 Motor mounting area dimensions Mitsubishi Electric Corporation Yaskawa Electric Corporation Manufacturer
R S D WX Bottom ported (Applicable O-ring) Hole Sizes for Centralized Piping on the Bottom WX Y S d D R Model MY1C16 MY1C20 WX Y S d D R Applicable O-ring Model 30 6.5 9 4 8.4 1.1 32 8 6.5 4 8.4 1.1 C6 (Machine the mounting side to the dimensions below.) 8-11-61 59 Series MY1C Standard Type/Centralized Piping Type 25, 32, 40 Refer to page 8-11-9 regarding centralized piping port variations
WX S R D Bottom side (ZZ) piping (applicable O-ring) Y 2-d (Machine the mounting side to the dimensions below.)
VXZ2230 VXZ2232 VXZ2240 VXZ2242 VXZ2350 VXZ2352 VXZ2360 VXZ2362 A J Q B T K R C U S D V E W F X H Y N.O.
Port 3 (R) 1/4 (P1) Refer to page 2449. 2 x port size Port 2 (A),1 (P) 2 x d Mounting hole A (Air operated) For bracket mounting Max. O Min.
VQ7-6-FG-SVQ7-6-FG-DVQ7-6-FPG-DVQ7-6-FG-S-R VQ7-6-FG-D-R VQ7-6-D-R VQ7-6-DNo.
Dimensions Note) A B 29 33 41 D 67 81 93 C 40 52 63 VQZ1000 VQZ2000 VQZ3000 35 43 52 A Note) For grommet Individual EXH spacer VVQZ1000-R-5-M5 (VQZ1000) VVQZ2000-R-5-01 (VQZ2000) VVQZ3000-R-5-02 (VQZ3000) M5: VQZ1000 Rc 1/8: VQZ2000 Rc 1/4: VQZ3000 Exhaust port can be installed individually by mounting an individual exhaust spacer on to the manifold block.
rate: 50% Stroke 500 mm Series CM2 Pressure 0.5 MPa Load rate: 50% Stroke 300 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation SY3140-01 Horizontal actuation 800 700 600 500 400 300 200 100 0 SY5140-02 800 700 600 500 400 300 200 100 0 SY7140-03 800 700 600 500 400 300 200 100 0 SY9140-04 Cylinder is in extending.
D-A9 (Reed switch) D-F9W D-M9 (Solid state switch) D-M9V, D-F9WV D-A9V (Reed switch) D-M9V D-F9WV (Solid state switch) C3 CXSJ15 to 32 Bore size (mm) C2 Symbol Auto switch model A1 32 0.3 7.1 6.2 3.1 25 0.3 7.1 6.2 0.4 20 0.3 7.1 6.2 1.2 15 0.3 7.1 6.2 2.2 C1 A1 C1 C2 C3 D-F9W, D-M9 D-A9V, D-F9WV D-M9V D-A9 (Reed switch) D-F9W (Solid state switch) D-M9 D-A9V (Reed switch) D-F9WV (Solid state
D-A9 (Reed switch) D-F9W D-M9 (Solid state switch) D-M9V, D-F9WV D-A9V (Reed switch) D-M9V D-F9WV (Solid state switch) C3 CXSJ15 to 32 Bore size (mm) C2 Symbol Auto switch model A1 32 0.3 7.1 6.2 3.1 25 0.3 7.1 6.2 0.4 20 0.3 7.1 6.2 1.2 15 0.3 7.1 6.2 2.2 C1 A1 C1 C2 C3 D-F9W, D-M9 D-A9V, D-F9WV D-M9V D-A9 (Reed switch) D-F9W (Solid state switch) D-M9 D-A9V (Reed switch) D-F9WV (Solid state
O.D. 6.8 to 11.5) G 1/2 (Applicable cable O.D. 6.8 to 11.5) 10-6-16 16 High Power Cylinder Series RHC Proper Auto Switch Mounting Position (Detection at stroke end) and Its Mounting Height Proper Auto Switch Mounting Position Auto Switch Mounting Height D-B5/B64 D-B59W D-G5/K59 D-B5 D-B64 D-H7 D-H7C D-H7NF D-H7W D-H7BAL D-G5 D-G5W D-G5NTL D-G5BAL D-K59 D-K59W D-B59W D-A33 D-A44 D-G39 D-K39
MB = ~Hs Auto switch = ~ Hs Auto switch MB1 CA2 CS1 Proper Auto Switch Mounting Position Auto Switch Mounting Height D-G5W D-K59W D-G59F D-G5 D-K5 D-G5NTL D-G5BAL D-H7 D-H7C D-H7W D-H7BAL D-H7NF C76 D-G5NTL D-G59F D-H7C D-G5BAL D-C7/C8 D-H7 D-H7W D-H7F D-H7BAL D-B5/B6 D-B59W D-G5/K5 D-G5W D-K59W Auto switch model D-C7/C8 D-C73C D-C80C D-C73C D-C80C D-B5/B6 D-B59W C85 Bore size (mm) C95 HS
D-X Auto switch 20Data Proper Auto Switch Mounting Position Auto Switch Mounting Height D-A5/A6 D-A3/ A3C D-A44/ A44C D-G39/ G39C D-K39/ K39C D-F5 D-J59 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL D-G5 D-K59 D-G5NTL D-G5W D-K59W D-G5BAL D-G59F D-F5 D-J5 D-F59F D-F5W D-J59W D-F5BAL D-B5/B64 D-B59W D-G5 D-K59 D-G5NTL D-G5W D-K59W D-G5BAL D-G59F Auto switch model D-A3 D-G39 D-K39 D-A44 D-A5 D-A6 D-A59W
OIl-Delay time 200 +/50mS Series CD5 Auto Switches D-A64 D-A59W D-853, A53 Reed Type Internal Circuit ~"e C) t ~R.o Reed sWltch Luminous diode Z"'" diode Zener dtlXle Surge absOtber D-A54, D-A44 D-A67 Reed sw~ch Zener dlode Indicator light I Operation R., ON Black (+) OperaUng (-) "'"!
8 6 D-F9, D-F9W 5 4 D-Z7, Z80 9 9 11 A B D-Y59, Y7P D-Y7W 6 6 6 Switches cannot be mounted in some cases.
8 6 D-F9, D-F9W 5 4 D-Z7, Z80 9 9 11 A B D-Y59, Y7P D-Y7W 6 6 6 Switches cannot be mounted in some cases.