(mm) 8 2.5 4 5 6.5 H Black (B) TUS related accessories Inner sleeve Series TJ White (W) D Red (R) Blue (BU) MS Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Yellow (Y) Reinforces soft polyuretharane tubing.

Output r8lponse Grommet Grommet Grommet Lead wire entry 1 mS or less 1 mS or less 1 mS or less " ~ ResponseUme ... ...

Metric 1/8" to 1" 1/8" to 1/2" 1/8" to 3/4" 1/8" to 1 1/4" Inch Translucent, Red, Blue, Black Translucent, Red, Blue, Black Translucent Translucent Color KQ2, KQG2, KP, KP KQ2, KQG2, KP, KP One-touch fittings Applicable fitting series M, MS (Hose nipple type) M, MS (Hose nipple type) M, MS (Hose nipple type) Miniature fittings KF, KFG2 KF, KFG2 KF, KFG2 Insert fittings LQ series LQ series

(Coil temperature: 20C, at rated voltage) 10-SY3000 10-SY7000 With light/surge voltage suppressor Response time (ms) (at the pressure of 0.5 MPa) With light/surge voltage suppressor Response time (ms) (at the pressure of 0.5 MPa) Actuation type Without light/surge voltage suppressor 12 or less Actuation type Without light/surge voltage suppressor 31 or less Type R, U Type S, Z 12 or less

Auto Switch Specifications Grommet With built-in OFF-delay timer (200 ms) PLC: Abbreviation of Programmable Logic Controller D-F5NTL (With indicator light) CRB2 D-F5NTL Auto switch model Wiring type 3-wire CRBU2 Output type NPN Output operation Off-delay CRB1 Operating time 1 ms or less Off-delay time 200 50 ms MSU Applicable load IC circuit, Relay, PLC CRJ Power supply voltage 5, 12, 24

(Response time selections with anti-chattering function: 20 ms, 160 ms, 640 ms, 1000 ms, 2000 ms) ZSP Short circuit protection With short circuit protection 0.5%F.S.

It takes 10 [ms] to switch the channel. CH.B Channel 10 [ms] 10 [ms] CH.A Time GND CH.SELECT terminal 10 [ms] 10 [ms] Disconnected Time 16-13-11 19 Technical Information 2-wire pressure switch connections 14 Voltage and current output pressure sensors 15 A 3-wire type switch is a switch that has an output line other than the positive and negative lines that supply the electricity.

Auto Switch Specifications Grommet With built-in OFF-delay timer (200 ms) PLC: Abbreviation of Programmable Logic Controller D-F7NTL (With indicator light) CUJ D-F7NTL Auto switch model Wiring type 3-wire CU Output type NPN Output operation Off-delay CQS Operating time 1 ms or less Off-delay time 200 50 ms CQM Applicable load IC circuit, Relay, PLC CQ2 Power supply voltage 5, 12, 24 VDC

Refer to fault SI unit SI unit MS LED is No.1 OFF malfunction Refer to fault SI unit PWR(V) LED No.2 is OFF Yes No Refer to fault SI unit L/A LED is No.3 OFF Refer to fault SI unit MS LED is No.4 red ON Refer to fault SI unit MS LED is No.5 red flashing Refer to fault SI unit MS LED is No.6 green flashing Refer to fault SI unit MS LED is SI unit NS LED is No.7 green ON OFF Refer to fault

Response time Life VQZ1000 10 ms 200 million cycles VQZ2000 12 ms VQZ3000 15 ms Built-in One-touch fittings for easier piping. Dispersion accuracy 2 ms Metal seal, single solenoid with light/surge voltage suppressor, according to SMC life test conditions. Integral One-touch fittings save on installation time and labor and can be easily removed if necessary.

Wireless System RoHS Usable even in welding environments High-speed connection Noise resistance Communication response Signal response time: 5 ms Uses the 2.4 GHz ISM frequency band Frequency hopping: Every 5 ms From power supply ON to start of communication: Min. 250 ms*1 *1 For wireless slave Communication cables not required Compatible protocol Number of I/O points Reduced wiring work,

-10 ~ 50C / 14 ~122F Ambient & Fluid Temperature 10 5 3 Max Operating 2 Position Single/Double 3 3 3 Frequency / Hz 3 Position Non Locking Push Type Manual Override Push Locking Slotted Type Push Locking Lever Type Common Exhaust for Main & Pilot Pilot Exhaust Free Mounting Position 0.23 0.59 0.87 Cv Factor M O D E L R E S P O N S E T I M E S E R I E S S Y 3 / 5 / 7 0 0 0 Response Time ms

Brown ON 80 mA Max. 24 VDC VS VL OFF White Release output Black ON Timer period Blue 20 to 2,000 ms Note) When power is supplied, release output is performed once for the time period only.

The operating time for D-J51 is 2 ms or less and for D-P3DW/P4DW are 40 ms or less. 4) 980 m/s2 for the trimmer type sensor section, 98 m/s2 for the amplifier section.

Available response time settings 20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms This function averages pressure values measured during the response time set by the user and then compares the average pressure value with the pressure set point value to output the result on the switch.

CE1R00C CE1RC 10-12-32 32 Counter CEU Operating Condition of each Output Mode One-shot Output With allowable values Without allowable values When the counter value passes the preset value, output is turned ON for 100 ms. When the counter value passes the sum of the preset value + the allowed value, output is turned ON for 100 ms.

50 ms PNP 2 output type LFElBlll Brown DC (+) Black OUT1 Max. 80 mA Load White OUT2 0 V or Load 50 ms 50 ms * When accumulated pulse output is selected, the indicator light is turned off.

PNP + Analog output type PF2M7mm-m-Em-mmm PF2M7mm-m-Fm-mmm Load White OUT2 (PF2M7 -B only) or 0 V 50 ms 50 ms 16 PF2M7(-L) Series Internal Circuits and Wiring Examples PF2M7mm-m-Lm-mmm NPN output type PNP output type Brown DC (+) Brown DC (+) Load U Main circuit Main circuit Main circuit Main circuit Black OUT1 Black OUT1 18 to 30 VDC + + Load Load 18 to 30 VDC U White N.C.