SMC Corporation of America
Elite Part Number Search
Search Results "NCDGBA50-1000-A93-XC6"

mass m [kg] 32 32 [Example] 50 50 40 40 32 32 10 10 1 100 500 1000 1 100 500 1000 400 300 200 400 300 200 Maximum speed V [mm/s] Maximum speed V [mm/s] Graph m Graph v 0.5 MPa P 0.5 MPa P 1000 1000 80 80 100 100 63 63 50 50 40 40 80 80 100 100 63 63 50 50 40 40 100 100 32 32 Load mass m [kg] Load mass m [kg] 50 50 32 32 10 10 1 100 500 1000 1 100 500 1000 400 300 200 400 300 200 Maximum

20 1000 1500 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 25 1500 2000 32 40 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 900, 1000 2000 1500 50 63 Note) Contact SMC if the maximum stroke will be exceeded.

Stroke (mm) Up to 10 Up to 30 Up to 50 Up to 75 Up to 100 Up to 1000 Up to 800 Up to 1000 Up to 1000 Up to 800 Up to 1000 Up to 1000 Max. speed (mm/s) 20 Selection graph (6) (7) (8) (9) (10) (11) (12) 25 32 Caution If the cylinder is horizontally mounted and the plate end does not reach the load's center of gravity, use the formula below to calculate the imaginary stroke l that includes the

Stroke (mm) Up to 10 Up to 30 Up to 50 Up to 75 Up to 100 Up to 1000 Up to 800 Up to 1000 Up to 1000 Up to 800 Up to 1000 Up to 1000 Max. speed (mm/s) 20 Selection graph (6) (7) (8) (9) (10) (11) (12) 25 32 Caution If the cylinder is horizontally mounted and the plate end does not reach the load's center of gravity, use the formula below to calculate the imaginary stroke l that includes the

50 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 6000 63 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 Made to Order Specifications (For details, refer to page 10-21-1.)

50 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 6000 63 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 Made to Order Specifications (For details, refer to page 10-21-1.)

MHF Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None MHL Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 MHR 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MHK 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and

MHF Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None MHL Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 MHR 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MHK 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and

Cylinder speed-1000 mm/sec. Sequencer response time-0.1 sec. Detecting point despersion-Within 100mm (=1000 mm/sec. X 0.1sec.) Take PLC response time into consideration when using.

Auto Switch Internal Circuit D-A90(V) Contact protection box OUT () Brown Reed switch Unit: g Weight CD-P11 OUT () Blue CD-P12 D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V Auto switch model Lead wire length: 0.5 m 6 6 6 6 8 8 D-A93(V) Lead wire length: 3 m 30 30 30 30 41 41 LED diode Brown OUT (+) Brown Contact protection box Resistor Unit: mm Dimensions Reed switch Zener diode CD-P11 D-A90/D-A93

L1 L2+A5 L3 2 1 W V 2 E= ( ) 2 9.8 1000 Collision speed V=1.4 Va *) Corrected coeficient 1 420 E= 1( ) =0.088 2 1000 V=1.4 X 300=420 Calculate kinetic energy E (J) of work. Calculate allwable kinetic energy Ea (J). Check that kinetic energy of work does not exceed allowable kinetic energy.

Examine for My My=10(10+30)/1000=0.4 A3=30 Examine for My My=10(30+10)/1000=0.4 A6=10 M=W(Ln+An)/1000 Corrected value for center position distance of moment An: Table 3 Calculate allowable static moment Ma(Nm) Ma=K Mmax Work mounting coeficient K: Fig.3 Allowable moment coeficient : Graph 2 Max. allowable moment Mmax: Table 4 2=M/Ma May=1 x 1 x 15.9=15.9 Mymax=15.9 K=1 =1 2=0.4/15.9=0.0252

D-A90(V) OUT() Brown Contact protection box CD-P11 CD-P12 Reed switch OUT() Blue Weight (g) D-A93(V) Model D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V LED Brown OUT (+) Brown 41 Lead wire length (m) 0.5 6 6 6 6 8 8 Contact protection box CD-P11 CD-P12 Resistor 3 30 30 30 30 41 Reed switch Zener diode Dimensions (mm) OUT () Blue Blue D-A90/D-A93/D-A96 2 2.8 4.5 2.7 D-A96(V) DC (+) Brown 4 LED

-X -XC57 With floating joint 20 1000 1500 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 2025 1200 1500 Minimum Operating Pressure 32 1500 2000 Data 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 900, 1000 0.2 Minimum operating pressure (MPa) 40 1500 2000 0.16 0.16 0.14 0.15 0.12 0.15 Note 1) Please contact SMC if the maximum stroke will be exceeded.

x 1.5 Up to 1000 19 G 1/2 25 32 55 40 398 65 15 17 6 160 20 58 27 M27 x 2 13 M12 x 1.75 19 Up to 1000 G 1/2 32 40 60 54 Minimum stroke for trunnion mounting are below.

75 133 368 Up to 1000 98 345 345 388.5 452 477 368 368 409.5 470 495 8 9 0.2 stroke 98 345 30 to 1000 75 133 368 98 Up to 1000 0.2 stroke 106 388.5 75 141 409.5 106 30 to 1200 Up to 1200 0.2 stroke 111 448 85 153 466 115 30 to 1200 Up to 1200 0.2 stroke 111 468 90 153 486 120 30 to 1200 Up to 998 0.2 stroke 141 579.5 105 176 595.5 30 to 1200 0.17 stroke 9-9-12 13 Series CLS Cylinder with

Support brackets are not for mounting; use them solely for providing support. (1400) (1400) (1400) (1400) (1400) (1400) MY1CW40 MY1CW40 MY1CW40 50 50 MY1MW32 MY1MW32 MY1MW32 MY1CW32 MY1CW32 (1100) (1100) (1100) (1100) 40 40 (1200) (1200) (1200) (1200) (1200) (1200) MY1MW25 MY1MW25 MY1MW25 MY1CW25 MY1CW25 MY1CW25 30 (1000) (1000) (1000) (1000) 30 MY1MW20 MY1MW20 MY1MW20 (1000) (900) (1000)

Support brackets are not for mounting; use them solely for providing support. (1400) (1400) (1400) (1400) (1400) (1400) MY1CW40 MY1CW40 MY1CW40 50 50 MY1MW32 MY1MW32 MY1MW32 MY1CW32 MY1CW32 (1100) (1100) (1100) (1100) 40 40 (1200) (1200) (1200) (1200) (1200) (1200) MY1MW25 MY1MW25 MY1MW25 MY1CW25 MY1CW25 MY1CW25 30 (1000) (1000) (1000) (1000) 30 MY1MW20 MY1MW20 MY1MW20 (1000) (900) (1000)

My = 0.5 x 9.8 (10 + 11)/1000 = 0.11 A3 = 11 May = 1 x 1 x 9.14 = 9.14 Mymax = 9.14 K = 1 = 1 2 = 0.11/9.14 = 0.012 Examine Mr.