SMC Corporation of America
Elite Part Number Search
Search Results "NCDJ2B10-150S-C80C"

D-C73C D-C80C D-B5/B6 D-G59F D-B59W Applicable bore size (mm) A A B A B B A B A B 16 (24) A B Hs Hs Hs 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 20 4.5 8 6 10 9 3 24.5 27 27.5 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 16 (24) 25 4.5 8 6 10 9 3 27 29.5 30 22.5 (30.5) 21.5 (29.5) 15.5 (23.5) 18.5 (26.5) 20.5 (28.5) 17 (25) 32 5.5 9 7 11 10 4 30.5 33 33.5 25

D-C73C D-C80C D-B5/B6 D-G59F D-B59W Applicable bore size (mm) A A B A B B A B A B 16 (24) A B Hs Hs Hs 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 20 4.5 8 6 10 9 3 24.5 27 27.5 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 16 (24) 25 4.5 8 6 10 9 3 27 29.5 30 22.5 (30.5) 21.5 (29.5) 15.5 (23.5) 18.5 (26.5) 20.5 (28.5) 17 (25) 32 5.5 9 7 11 10 4 30.5 33 33.5 25

Contact Protection Boxes/CD-P11, CD-P12 Auto Switch Internal Circuits Reed switches D-C73 D-C7/C8, D-C73C/C80C, D-B53, D-P75 The above auto switches do not have internal contact protection circuits. 1. The operating load is an induction load. 2. The length of wiring to the load is 5m or more. 3. The load voltage is 100VAC.

Auto switch model Electrical entry direction In-line C76 C73 B53 B54 B64 C80 C73C C80C B59W H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA G5NT H7NF Load voltage Lead wire* (m) 0.5 () Indicator Wiring (Output) Electrical entry Applicable load Style Special function 3 (L) 5 (Z) (N) AC DC Prependicular B76 B73 5V IC 3 wire(Equiv.

Load voltage Auto switch model Lead wire length (m)* Indicator Wiring (Output) Electrical entry Applicable load Direction of switch mounting screw In-line C76 C73 B53 B54 B64 C80 C73C C80C B59W H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA G5NT H7NF Style Special function 0.5 () (L) (Z) (N) None 3 5 AC DC Perp. B76 B73 I.C. 5V P P P P P P P P P P P P P P P P P 3 wire (Equiv.

Contact Protection Boxes/CD-P11, CD-P12 Auto Switch Internal Circuits Reed switches D-C73 D-C7/C8, D-C73C/C80C, D-B53, D-P75 The above auto switches do not have internal contact protection circuits. 1. The operating load is an induction load. 2. The length of wiring to the load is 5m or more. 3. The load voltage is 100VAC.

Solid state auto switch : D-H7, D-H7C, D-H7W, D-H7NF, D-H7BA Reed auto switch : D-C7, D-C80, D-C73C, D-C80C, D-A80, D-A9, D-A9V, D-A79W, D-A73 CM2 series C port Stroke A Stroke B A port B port (mm) Bore size (mm) SA SB ZZ 20 48 62 164 25 48 62 168 32 50 64 172 SA + Stroke A SB + Stroke B 40 67.5 88.5 222 ZZ + Stroke (A + B) CM2R series A port B port C port (mm) Bore size (mm) SA SB ZZ 20

Yes/3 Wire (PNP) Yes/2 Wire Yes/4 Wire (NPN) Yes/4 Wire (NPN) Yes/2 Wire No/3 Wire (NPN) Yes/2 Wire D-G59 D-G5P D-K59 D-5NTL D-H7A1 D-H7A2 D-H7B D-H7C D-G59W D-G5PW D-K59W D-G59F D-G79 D-H7PW D-H7BAL D-H7LF D-H7NF D-G5BAL D-H7PW D-H7BW 24VDC 110VAC 220VAC 24VDC 24VDC 110VAC 220VAC 24VDC 110VAC Yes/2 Wire D-B54 Yes/2 Wire D-B53 No/2 Wire D-B64 D-B73 D-C73 D-C73C D-B76 D-C76 D-B80 D-C80 D-C80C

Plug-in connector assembly D-A7OC, ASOC D-J79C D-C73C, C80C D.H7C With the convexport ofthe connector uppermost, insert the connector into the auto switch up to the sleeve. Screw the locking ring on to the switch. (Do not tighten with pliers.)

Yes/3 Wire (PNP) Yes/2 Wire Yes/4 Wire (NPN) Yes/4 Wire (NPN) Yes/2 Wire No/3 Wire (NPN) Yes/2 Wire D-G59 D-G5P D-K59 D-5NTL D-H7A1 D-H7A2 D-H7B D-H7C D-G59W D-G5PW D-K59W D-G59F D-G79 D-H7PW D-H7BAL D-H7LF D-H7NF D-G5BAL D-H7PW D-H7BW 24VDC 110VAC 220VAC 24VDC 24VDC 110VAC 220VAC 24VDC 110VAC Yes/2 Wire D-B54 Yes/2 Wire D-B53 No/2 Wire D-B64 D-B73 D-C73 D-C73C D-B76 D-C76 D-B80 D-C80 D-C80C

Plug-in connector assembly D-A7OC, ASOC D-J79C D-C73C, C80C D.H7C With the convexport ofthe connector uppermost, insert the connector into the auto switch up to the sleeve. Screw the locking ring on to the switch. (Do not tighten with pliers.)

D-C7 D-C80 15 2 (Different sides) 10 1 D-H7 D-H7W D-H7NF D-H7BAL 60 2 (Same side) Band mounting style 1 2 Ek = m2 15 2 (Different sides) 10 1 65 2 (Same side) D-C73C D-C80C D-H7C 15 2 (Different sides) 10 1 Weight (g) Bore size (mm) 16 Standard weight 320 Additional weight per each 15 mm of stroke 6.5 9 27 Axial foot style 8 Mounting bracket weight 21 Rod side flange style 7 Double clevis

Lead wire length indication Note 1) Applicable auto switch with 5 m lead wire (Z) Reed switch: D-B53/B54, DC73(C)/C80C, D-A73(C)(H)/ A80C, D-A53/A54, D-Z73, D90/97/90A/93A Solid state switch: Manufactured upon receipt of order as standard.

D-C7 D-C80 15 2 (Different sides) 10 1 D-H7 D-H7W D-H7NF D-H7BAL 60 2 (Same side) Band mounting style 1 2 Ek = m2 15 2 (Different sides) 10 1 65 2 (Same side) D-C73C D-C80C D-H7C 15 2 (Different sides) 10 1 Weight (g) Bore size (mm) 16 Standard weight 320 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area:

Lead wire length indication Note 1) Applicable auto switch with 5 m lead wire (Z) Reed switch: D-B53/B54, DC73(C)/C80C, D-A73(C)(H)/ A80C, D-A53/A54, D-Z73, D90/97/90A/93A Solid state switch: Manufactured upon receipt of order as standard.

Note 1) Lead wire length Z: Auto switches applicable for 5m Reed switch: D-B53/B54, D-C73(C)/C80C, D-A73(C)(H)/A80C D-A53/A54, D-Z73, D-90/97/90A/93A Solid state switch: All models are produced upon receipt of order (standard procedure). However, this does not include D-F9, F9V and F7WV.

Lead wire length indication Note 1) Applicable auto switch with 5 m lead wire (Z) Reed switch: D-B53/B54, DC73(C)/C80C, D-A73(C)(H)/ A80C, D-A53/A54, D-Z73, D90/97/90A/93A Solid state switch: Manufactured upon receipt of order as standard.

Lead wire length indication Note 1) Applicable auto switch with 5 m lead wire (Z) Reed switch: D-B53/B54, DC73(C)/C80C, D-A73(C)(H)/ A80C, D-A53/A54, D-Z73, D90/97/90A/93A Solid state switch: Manufactured upon receipt of order as standard.

switch model Band mount (16) Indicator light Wiring (output) Electrical entry Applicable load Rail mount Special function Type 5 (Z) None (N) 0.5 (Nil) 3 (L) DC AC Perpendicular In-line 3 wire (NPN) C76 A76H 5V IC circuit Yes A72 A73 A80 A73C A80C A79W F7NV F7PV F7BV J79C F7NWV A72H A73H A80H Grommet 200V Reed switch Solid state switch Rail mount type CDJ2XB10-45-A Example C73 C80 C73C C80C

Electrical entry Type Model Feature D-A80 Grommet D-A80H Connector D-A80C Without indicator light Reed switch Grommet D-C80 Connector D-C80C Grommet With timer D-F7NTL Solid state switch D-F7NTL is also available with pre-wired connector. 2 End Lock Cylinder Series CBJ2 Dimensions Basic With front end lock / CBJ2B16-RN 14.5 0 h8-0.022 10 5 M10 x 1 Piping port 2-M5 x 0.8 20 M5 x 0.8 20.3