SMC Corporation of America
Elite Part Number Search
Search Results "NCDY2S25H-1200-A72"

Leakage current from switch is 1 mA. 12-13-6 7 Reed Switch Band Mounting Style D-A72/D-A73/D-A80 For details about certified products conforming to international standards, visit us at www.smcworld.com.

Magnet: Built-in, Bore Size: 1 Inch, Magnetic Holding Force: Small Holding Force, Stroke: 12 Inch, Adjuster: Adjuster Bolt, Auto Switch: A72--Reed, AC Volt.<200, LED, Lead Wire, Vertical, 0.5M, Number: -

Magnet: Built-in, Bore Size: 1 1/2 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 12 Inch, Adjuster: Adjuster Bolt, Auto Switch: A72--Reed, AC Volt.<200, LED, Lead Wire, Vertical, 0.5M, Number: -

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1200 (12 Inch)

Magnet: Built-in, Bore Size: 1 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 12 Inch, Adjuster: -, Auto Switch: -, Number: -

Weight (g) D-A72 D-A73 D-A80 Auto switch model 0.5 m (Nil) 10 10 10 3 m (L) 47 47 47 Lead wire length 5 m (Z) 77 Dimensions (mm) 8 3.2 Indicator light D-A80 without indicator light 15 (14) 7 (6) 4 23 (22) 11.5 (11.7) 3.4 6 (6.2) 3 Most sensitive position 9 (8.5) ( ) values for D-A72 1636 Reed Auto Switch Rail Mounting Style D-A7H/D-A80H Refer to SMC website for the details of the products

258-9200-www.stevenengineering.com D-A73C D-A80C B 24 A Hs 18.6 B 16 A 29 D-H7 D-H7W D-H7BAL D-H7NF Hs 8.5 1 7 23.5 A B D-A79W 14 Hs A 38.2 B 16 D-H7C Hs D-F7 D-F7W D-J79 D-J79W D-F7BAL D-F79F 23 A B 1 8.5 Hs 11 13.3 13.3 10 A B 26 Auto Switch Mounting Position (mm) D-J79C 17 D-C7 D-C80 D-C73C D-C80C D-A73 D-A80 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-F7V D-F7WV D-J79C D-F7BAL D-F79F/A72

Solid state auto switch 12 V 2-wire Connector M9NW M9PW M9BW M9NA1 3-wire (NPN) Diagnostic indication (2-color indicator) IC circuit 5 V, 12 V 12 V Relay PLC 24 V 3-wire (PNP) 2-wire Yes Grommet 3-wire (NPN) IC circuit 5 V, 12 V Water resistant (2-color indicator) M9PA1 M9PAV1 3-wire (PNP) 2-wire 4-wire M9BA1 M9BAV1 12 V 5 V, 12 V F79F IC circuit Diagnostic output (2-color indicator) A96V A72

Direct mounting Wire length (1) (m) Load voltage Rail mounting Special function Style Electrical entry Wiring (Output) Indicator 32, 40 12 to 40 Applicable load 0.5 () 3 (L) 5 (Z) (N) AC DC Perpendicular In-line Perpendicular In-line 3 wire (Equivalent to NPN) A96V A96 A76H 5V IC A72H A72 200V Yes Grommet Reed switch Solid state switch A73 A73H 100V 12V A93V A93 Relay PLC 2 wire A90V

The value of the auto switchs hysteresis as represented by an angle Hysteresis angle : 3. 4. 5. 11-10-16 17 Rotary Cylinder with Auto Switch Series MRQ Auto Switch Mounting Dimensions Reed switch D-A7/A80 D-A7H D-A73C/A80C CRB2 (In parentheses) are the dimensions of A72.

Lead wire length (m) Load voltage Rail mounting Indicator light Wiring (Output) Special function Type Electrical entry Pre-wired connector Applicable load 0.5 (Nil) 3 (L) 5 (Z) None (N) AC Perpendicular In-line DC IC circuit 3-wire (NPN equivalent) A76H 5 V Reed switch Solid state switch Grommet A72H A73H F79 F7P J79 F79W F7PW J79W F7BA F79F A72 A73 A73C A79W F7NV F7PV F7B J79C F7NWV

Lead wire length (m) Load voltage Rail mounting Indicator light Wiring (Output) Special function Type Electrical entry Pre-wired connector Applicable load 0.5 (Nil) 3 (L) 5 (Z) None (N) AC Perpendicular In-line DC IC circuit 3-wire (NPN equivalent) A76H 5 V Reed switch Solid state switch Grommet A72H A73H F79 F7P J79 F79W F7PW J79W F7BA F79F A72 A73 A73C A79W F7NV F7PV F7B J79C F7NWV

D-A72 (H) must be used with the contact protection box regardless of load styles and lead wire length. None N Applicable for the connector style (D-C) only. Note 1) Lead wire length Z: 5 m applicable auto switches Reed switch: D-A73 (C) (H), A80C Solid state switch: All types are produced upon receipt of order.

1" Black D-F79F D-F7LF D-F7NTL o oiagnoslic ouipui OUT 2 o Series NCDQT Auta-Switch / Operating Range D-A72. D-A73, D-A80 D-A72H, O.A73H, O.A76H, D-A8OH, D-F7NTL, D-F7P, D-F79, D.F79W, O-J79, D..t79W D-Fltr WV, D-F7tr V t,.A73C, D-A80C, D-J79C op6drirE ElE6 (* lid be*rw) I, Dimensiltn / Operating Range Series NCDQT Solid.

NPN) IC A76H 5V Yes A72H A72 200V Grommet Reed switch Solid state switch A73H A73 100V 12V 5V 12V 100V or less Stroke (mm) No A80H A80 IC Relay, PLC 2 wire Refer to standard stroke on p.2.4-3. Refer to p.2.4-3 when using auto switch.

1" Black D-F79F D-F7LF D-F7NTL oiagnoslic ouipui OUT 2 o o Series NCDQT Auta-Switch / Operating Range D-A72. D-A73, D-A80 D-A72H, O.A73H, O.A76H, D-A8OH, D-F7NTL, D-F7P, D-F79, D.F79W, O-J79, D..t79W D-Fltr WV, D-F7tr V t,.A73C, D-A80C, D-J79C op6drirE ElE6 (* lid be*rw) I, Dimensiltn / Operating Range Series NCDQT Solid.

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1200 (12 Inch), Adjuster: Adjuster Bolt, Auto Switch: F7PZ--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Horizontal, 5M

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1200 (12 Inch), Adjuster: Adjuster Bolt, Auto Switch: A73HZ--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 5M

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1200 (12 Inch), Adjuster: Adjuster Bolt, Auto Switch: A73L--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 3M

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1200 (12 Inch), Adjuster: Adjuster Bolt, Auto Switch: J79L--Solid State, Gen. Purpose, 2 Wire, Lead Wire, Horizontal, 3M