Cylinder (Tube) Inner Diameter(φ): 1 1/16", Stroke(mm): 5/8", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Both Ends Tapped, Body Options
Cylinder (Tube) Inner Diameter(φ): 3/4", Stroke(mm): 5/8", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Through hole, Body Options: Female
Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 5/8", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Through hole, Body Options: Female
Cylinder (Tube) Inner Diameter(φ): 2", Stroke(mm): 5/8", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Through hole, Body Options: Female Rod
Cylinder (Tube) Inner Diameter(φ): 1 1/16", Stroke(mm): 5/8", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Both Ends Tapped, Body Options: Female
Cylinder (Tube) Inner Diameter(φ): 1 1/16", Stroke(mm): 5/8", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Through hole, Body Options: Female Rod End
Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 5/8", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Through hole, Body Options: Female Rod
Cylinder (Tube) Inner Diameter(φ): 1 1/16", Stroke(mm): 5/8", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Rear Clevis, Body Options: Female Rod
Cylinder (Tube) Inner Diameter(φ): 1 1/16", Stroke(mm): 5/8", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Both Ends Tapped, Body Options
Cylinder (Tube) Inner Diameter(φ): 3/4", Stroke(mm): 5/8", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Through hole, Body Options: Female
Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 5/8", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Through hole, Body Options: Female
Cylinder (Tube) Inner Diameter(φ): 2", Stroke(mm): 5/8", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Through hole, Body Options: Female Rod
Cylinder (Tube) Inner Diameter(φ): 1 1/16", Stroke(mm): 5/8", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Rear Clevis, Body Options: Female Rod
Cylinder (Tube) Inner Diameter(φ): 1 1/16", Stroke(mm): 5/8", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Rear Clevis, Body Options: Female Rod
KBP2 KBR2-1 KBR3-2 KBR4-3 KBV2-06 KBL2-R2S 4 Plug/Cap: KBP, KBC (P.2.1-80) Component module KBV2-063 KBE2-061 KBP2 1 KB P 1 KBP2 KBE2-06 Body size KBE2-06 KBV2-06 Style Plug: KBP Cap: KBC Component module KBV2-062 KBE2-062 KBN21 Part No. Part No.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com TU h TT Stroke adjusting unit (mm) E EC FC h S SD T TT TU W Shock absorber model EY Applicable cylinder MY3B16 MY3B25 MY3B40 MY3B63 26.5 14.1 21.5 034.5 2.4 40.8 25.8 06 0.9 25.0 062 RB0806 36.5 20.1 29.8 051.5 3.6 46.7 25.2 07 1.4 28.5 090 RB1007 53.5
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com TU h TT Stroke adjusting unit (mm) E EC FC h S SD T TT TU W Shock absorber model EY Applicable cylinder MY3B16 MY3B25 MY3B40 MY3B63 26.5 14.1 21.5 034.5 2.4 40.8 25.8 06 0.9 25.0 062 RB0806 36.5 20.1 29.8 051.5 3.6 46.7 25.2 07 1.4 28.5 090 RB1007 53.5
New Products Guide 1 Directional Control Valves Actuators Vacuum Equipment CAT.E00-6A INDEX New Products Guide 1 Directional Control Valves 5 Port Solenoid Valve Fieldbus System (For Input/Output) 2/3 Port Mechanical Valve Series SY3000/5000/7000 Series EX600 Series VM100/200 P .6 P .264 P .322 Actuators Foot Pedal Type 5 Port Mechanical Valve XT34-60/67 Air Cylinder Air Cylinder Series CJ2
Removal of foreign particles 3 to 5 mm longer Lub-retainer Heavy-duty scraper 91-XC4 spec. 91-CQ2-XC4 Series Front matter 4 90Series Pneumatic equipment material restriction Mounting dimensions are the same as those of the standard series. *Coils for solenoid valves, connector pins, and lead wires are made of copper. Solenoid Valve Changed to with resin pre-wired connector.
XC4 XC4 Mounting Bore size Stroke Cushion (With rear lock only) CG1 CQ2 Follow the standard ordering procedures. XC4 XC4 Follow the standard ordering procedures. CA1 CV Follow the standard ordering procedures. XC4 XC4 Follow the standard ordering procedures. CS1 MGG Follow the standard ordering procedures. XC4 XC4 Follow the standard ordering procedures.