Part Number Description: COUPLER BASIC NAC5/6000(BASIC) Product Line: E Product Line Description: AIRLINE EQUIPMENT Family Code: 100 Family Description: AC FRL COMBO Class Code: 22 Part Code: 2 Reference Code: B Click here to report information errorImage shown may not match exact part number, COUPLER BASIC NAC5/6000(BASIC), AIRLINE EQUIPMENT, AC FRL COMBO, 22, AC NO
Part Number Description: COUPLER L-TYPE NAC5/6000 L-BKT Product Line: E Product Line Description: AIRLINE EQUIPMENT Family Code: 100 Family Description: AC FRL COMBO Class Code: 22 Part Code: 2 Reference Code: B Click here to report information errorImage shown may not match exact part number, COUPLER L-TYPE NAC5/6000 L-BKT, AIRLINE EQUIPMENT, AC FRL COMBO, 22, AC NO
Part Number Description: COUPLER T-TYPE NAC5/6000 T-BKT Product Line: E Product Line Description: AIRLINE EQUIPMENT Family Code: 100 Family Description: AC FRL COMBO Class Code: 22 Part Code: 2 Reference Code: B Click here to report information errorImage shown may not match exact part number, COUPLER T-TYPE NAC5/6000 T-BKT, AIRLINE EQUIPMENT, AC FRL COMBO, 22, AC NO
Delivery Pressure: P [50 to 6000 psig (0.34 to 41.4 MPa)], Relieving: 1 (Self-relieving, Standard), Material: C (300 SS Series), Ports: 4P (4 Ports), Connections: 4 (NPT 1/4 Inch), Gauge Port, Inlet: Q [10000 psig (70 MPa)], Gauge Port, Outlet: 60 [6000 psig (41 MPa)], Pressure Gauge Unit: psig/bar (or None in Case of no Gauge), Main Valve Seat Material: Vespel®, Standard, O-ring Material
Base mounted VFS2000 series, Single/Body ported VFS1000/2000/3000 series: ① Body ported VFS series
Single/Base mounted VFS2000 series:② Base mounted VFS2000 series
Single/Base mounted VFS3000/5000/6000
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Weight (kg) 0.05 0.075 AC4000/5000/5500/6000 AR4000/5000/6000 AW4000 Applicable model C Part no.: 1305104-1A C1 Attachment: With cover ring assembly Part no.: 1305104-3A Note 1) Indicates the condition at the lower pressure limit.
PAT. 17-5-172 33 Flow Switch Series PF, IF For Air Digital Flow Switch/Series PFA Display integral type Output specification Port size (Rc, NPT, G) Flow rate range (l/min) Separate type Display Sensor Switch output Analog output Accumulated pulse output PFA710 750 711 721 751 703H 706H 712H PFA510 550 511 521 551 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 150 to 3000 300 to 6000 6000 to
Flow capacity (l/min (ANR)) Oil mist concentration at outlet side 300 750 1500 2200 3500 Filtration (m) Port size Rc Model AM150 AM250 AM350 AM450 AM550 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 Max. 1.0 mg/m3 (ANR) ( 0.8 ppm) , , , , , , , , , 1 1 0.3 1 2 3 4 3 4 1, 1 2 1 , 2 AM650 6000 AM850 12000 1 2 Can produce with auto drain type, drain piping type.
70C (Application of rated voltage) Temperature rise Power consumption DC Holding Inrush 5.6VA(50Hz), 5.0VA(60Hz) 12VA(50Hz), 10.5VA(60Hz) 3.4VA(50Hz), 2.3VA(60Hz) 7.5VA(50Hz), 6VA(60Hz) 1.8W 4.8W Apparent power AC Non-locking push style Others (Option) Manual override Non-locking push style 4.2-5 VNA Flow Characteristics Air How to Read The Graph In the sonic flow region: For a flow of 6000
, 2" , NPN or PNP open collector, 1 output + analog , Flow rate (l/min): 150~3000, 300~6000, 600~12000, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, JB, IF/PFA 1 1/2 INCH NPT VERSION, 4.23287 lb, ModelMeasured fluidDetection typeRated flow range Note 1)Minimum set unit Note 1)Note 2)Display unitsOperating pressure rangeProof pressurePressure lossAccumulated
Recommended torque: 12 to 14 Nm. 231 MR Unit (Regulator with Mist Separator) AMR3000 to 6000 Replacement Procedure is P.448 Construction !1 t OUT IN u MC cartridge element Flow hole A Separation element i y Auto-drain type o !0 r Port size 1/4 Drain The numbers are the same as the "Construction" of the Best Pneumatics No.5 Series AMR.
Filter P.402 AFM Modular Type Mist Separator P.402 AFD Modular Type Micro Mist Separator P.404 AR Modular Type Regulators P.412 AL Modular Type Lubricators P.420 AW Modular Type Filter Regulators P.431 ARG Modular Type Regulator with Built-in Pressure Gauge P.437 AWG Modular Type Filter Regulator with Built-in Pressure Gauge P.444 AR425 to 925 Pilot Operated Regulator P.448 AMR3000 to 6000
Delivery Pressure: P [50 to 6000 psig (0.34 to 41.4 MPa)], Relieving: 1 (Self-relieving, Standard), Material: B (Brass), Ports: 4P (4 Ports), Connections: 4 (NPT 1/4 Inch), Gauge Port, Inlet: 60 [6000 psig (41 MPa)], Gauge Port, Outlet: 20 [2000 psig (14 MPa)], Pressure Gauge Unit: psig/bar (or None in Case of no Gauge), Main Valve Seat Material: Vespel®, Standard, O-ring Material: VitonÂ
Delivery Pressure: P [50 to 6000 psig (0.34 to 41.4 MPa)], Relieving: 1 (Self-relieving, Standard), Material: B (Brass), Ports: 4P (4 Ports), Connections: 4 (NPT 1/4 Inch), Gauge Port, Inlet: 60 [6000 psig (41 MPa)], Gauge Port, Outlet: 20 [2000 psig (14 MPa)], Pressure Gauge Unit: psig/bar (or None in Case of no Gauge), Main Valve Seat Material: Vespel®, Standard, O-ring Material: VitonÂ
Delivery Pressure: P [50 to 6000 psig (0.34 to 41.4 MPa)], Relieving: 1 (Self-relieving, Standard), Material: C (300 SS Series), Ports: 4P (4 Ports), Connections: 4 (NPT 1/4 Inch), Gauge Port, Inlet: 60 [6000 psig (41 MPa)], Gauge Port, Outlet: 20 [2000 psig (14 MPa)], Pressure Gauge Unit: psig/bar (or None in Case of no Gauge), Main Valve Seat Material: Vespel®, Standard, O-ring Material
Delivery Pressure: P [50 to 6000 psig (0.34 to 41.4 MPa)], Relieving: 1 (Self-relieving, Standard), Material: B (Brass), Ports: 4P (4 Ports), Connections: 4 (NPT 1/4 Inch), Gauge Port, Inlet: Q [10000 psig (70 MPa)], Gauge Port, Outlet: 60 [6000 psig (41 MPa)], Pressure Gauge Unit: psig/bar (or None in Case of no Gauge), Main Valve Seat Material: Vespel®, Standard, O-ring Material: VitonÂ
, 2" , NPN or PNP open collector, 1 output + analog , Flow rate (l/min): 150~3000, 300~6000, 600~12000, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, JB, IF/PFA 1 1/2 INCH NPT VERSION, 3.99153 lb, ModelMeasured fluidDetection typeRated flow range Note 1)Minimum set unit Note 1)Note 2)Display unitsOperating pressure rangeProof pressurePressure lossAccumulated
6000 0.8 MPa 0.5 MPa 0.8 MPa 0.5 MPa 4000 4000 0.3 MPa 2000 2000 0.3 MPa 0 50 100 150 200 250 300 0 50 100 150 200 250 300 Arm length [mm] Arm length [mm] Bore size: 63, Arm length: 200 mm, Operating pressure: 0.5 MPa With an arm length of 200 mm and an operating pressure of 0.5 MPa, according to the graph, the maximum clamping force is 2000 N.
Recommended shim thickness) Arm length L: 8 in 0.08 0.04 0.12 For Asia For North America For Europe For France Special 800 Clamping force (lbf) 0.7 MPa 600 0.5 MPa 0.3 MPa 400 200 0 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 Shim thickness (in) 80 Arm length L: 250 mm 7000 6000 5000 4000 3000 2000 1000 0 Clamping force (N) 0.7MPa 0.5 MPa 0.3 MPa 0 1 2 2.5 3.5 3 4 5 6 7 8 9 Shim thickness (mm) (Ex.
Example: 3) From Table 2, determine Stop Tube Requirements ~ 1) From Table 1, determine Stroke Factor (SF) ~ NCDA1L800-6000-XTATCDN Find L length and note Stop Tube length Stroke Factor 2.0 8 Bore Stop Tube Length = 8 60 Stroke 2) Determine Effective Length L MS1 Mount L = Stroke x Stroke Factor Supported but not rigidly guided = 60 x 2.0 = 120 inches 21 Engineering Specifications Expanded