Reset (RES) Keeping RY(n 1)A or RY(n 3)A (RES) ON for 50ms or longer RY(n 1)A RY(n 3)A 1 allows an alarm to be deactivated. Some alarms cannot be deactivated by Reset RY(n 1)A or RY(n 3)A (RES). (Refer to section 10.4.1.) If RY(n 1)A or RY(n 3)A (RES) is turned ON with no alarm occurring, the base circuit will not be shut off.
Please change the parameter in the initial setting. *3 The minimum unit of the travel distance of the actuator should be 1 [m]. *4 When the motor mounting position is right side parallel (LEY*R / LEYG*R) or left side parallel (LEY*L / LEYG*L), the rotation direction selection is 0(+: Counter motors side). -28- LEY63 LEY63D Lead symbol A B C L A B C Series Lead 5(2.86) 20 10 5 20 10 5 (Including
A Station 1 1 SOL. A Station 2 14 SOL. A Station 3 2 VQD 1 SOL. A Station 4 14 15 2 SOL. A 15 3 3 4 5 6 7 8 9 10 11 12 13 Station 5 16 17 18 19 20 21 22 23 24 25 SOL. B 16 SOL. A 4 Station 6 SOL. B DIN rail mounting bracket [-D] VVQ1000-57A for {F, L, M, P, S (EX500) kit} VVQC1000-57A-S for {S (EX250) kit} VVQC1000-57A-T for {T, S (EX126) kit} 17 SOL. A 5 Station 7 SOL. B 18 SOL.
NP L H PP 0002h A-phase pulse train B-phase pulse train NP EX.)
SERIES GATEWAY UNIT EX500 SERIES GATEWAY UNIT PE PE PWR LINK RUN SOL SOL BUS COM L RUN OUT 12 12 ERR L ERR. 88 73 63 73 63 88 LINK OUT COM D COM C COM B COM A 24VDC COM D COM C COM B COM A 24VDC Power connector Power connector Marker (Phoenix Contact) Branch connector Branch connector Marker (Phoenix Contact) 160 136 160 136 93.5 or less 48.8 46 10 48.8 46 10 How to Order Input manifold
Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: L (Out 1: IO-Link or NPN/PNP), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Rated Flow Range: 0.3 to 25 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order: -
Rated Flow Range: 0.3 to 25 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: Lead Wire w/Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: Panel Mount Adapter, w/o Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order: -
Rated Flow Range: 0.3 to 25 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: PNP; Out 2: PNP, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: L4 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 4 to 20 mA), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate)
Supply pressure verification Leak test P2(n1) > P1(n2) P2(n2) P1(n1) 10.0 to 101.0kPa CH Increases the set value 1 2 3 4 PRESSURE For normally closed P2(n1) > P1(n2) P2(n2) P1(n1) 0.1 to 1000.0MPa Decreases the set value SET P3(n3) and P4(n4) are the same as P1(n1) and P2(n2).
OUT2 P2(n2) P1(n1) Supply pressure verification Leak test CH P2(n1) > P1(n2) 10.0 to 101.0 kPa Increases the set value 1 2 3 4 PRESSURE For normally closed P2(n2) P1(n1) P2(n1) > P1(n2) 0.1 to 1000.0 MPa Decreases the set value SET P3(n3) and P4(n4) are the same as P1(n1) and P2(n2).
Supply pressure verification Leak test P2(n1) > P1(n2) P2(n2) P1(n1) 10.0 to 101.0kPa CH Increases the set value 1 2 3 4 PRESSURE For normally closed P2(n1) > P1(n2) P2(n2) P1(n1) 0.1 to 1000.0MPa Decreases the set value SET P3(n3) and P4(n4) are the same as P1(n1) and P2(n2).
A) Roll moment M2 = WL (mm) Model REBH15 REBH25 REBHT25 REBHT32 A 17.5 23.5 0 L L A L 0 M2 Since there are 2 guides, the guides central axis and the cylinder's central axis are the same.
(Values at the initial period) JIS Symbol (A) 4 (B) 2 1 (P) 3 (R) 2-8-4 5 4 Port Direct Operated Poppet Solenoid Valve Series VQD1000 Flow Characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) Flow characteristics Valve model Port size C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv L M L M L M L M Body ported VQD1121-M5 0.05 0.31 0.19 0.05 0.16 0.22 U W VQD1121 -M5 0.07 0.28 0.28 0.07 0.24 0.27
(A) 2 L: L type (VQ20 only) 1 Directional Control Equipment 1 (P) Note) Consult SMC for N.O. type. Note) Specify "LF" for L type with bracket.
4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 One-touch fitting (X, PE port) Applicable tubing O.D.: 6, 1/4" One-touch fitting [4(A), 2(B) port] Applicable tubing O.D.: 4, 5/32" 6, 1/4" (L4) L3 (3.2) 113.7 U side D side 3.1 8 36.3 58.2 5.5 35 18 28.8 70.7 B COM A B COM A B COM A B COM A B COM A DIN rail holding screw Manual override DIN rail (Press and turn for the locking type.) 4(A) port side: