Set value P_1 Hysteresis H_1 Piping Tightening the connection thread For connecting to the body (piping specification: -M5) After hand tightening, apply a spanner of the correct size to the spanner flats of the piping body, and tighten with a 1/6 to 1/4 rotation. As a reference, the tightening torque is 1 to 1.5 Nm.
NOTE (1) Press and hold the SET button between 1 and 3 sec. in measurement mode. [SEt] is displayed on the main display.
NOTE (1) Press and hold the SET button for 1 and 3 sec. in measurement mode. [SEt] is displayed on the main display.
Description F80 F10 [LEvEL] Level meter [ ON] Normal operation 2 1 DC(+) 2 To obtain the operation manual about this product and control unit, please refer to the SMC website (URL http://www.smcworld.com) or contact SMC directly.
Simple Setting Mode Press the and buttons 1 second or longer to recover from error. Try copy function after checking wiring, product model etc. NOTE Copy error Fail to operate copy function. (1) Press and hold the button between 1 and 3 seconds in measurement mode. [SEt] is displayed on the main display.
[F 3] Response time setting 1 second Installation The accumulated flow range is exceeded. (In some flow ranges, the decimal point may flash.) Excessive accumulated flow [F10] Selection of sub screen Display of set value Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result.
System error Displayed if an internal data error has occurred. , (1) Press and hold the button between 1 and 3 seconds in measurement mode. [SEt] is displayed on the main display.
Operation (1)Set the items on the sub display (set value or hysteresis) with the UP or DOWN button.
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 10 (1), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 10 (1), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 10 (1), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 10 (1), Output Specification: 2 (OUT1: Analog 4 to 20mA)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 10 (1), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector)
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 1, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: -, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 1, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: -, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 1, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: -, Units on Label: -, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 1, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: -, Lead Wire: -, Units on Label: -, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 1, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: -, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material)