SMC Corporation of America
Elite Part Number Search
Search Results "PFCA750-C6-1-M"

(max. 20 stations) 3 SY3000 5 SY5000 Connector mounting position A, B port size Symbol Mounting position U U side SY5000 SY3000 D D side Symbol Port size 4 One-touch fitting C4 Symbol Port size 4 One-touch fitting C4 6 One-touch fitting C6 Mixed M 6 One-touch fitting C6 Valve stations 8 One-touch fitting C8 Mixed M Stations Symbol Note Single wiring specifications (up to 16 solenoids are

(compared with current shading coil) Size 1 } } 1/8 Size 2 } 1/8, 1/4, 3/8 Reduced buzz noise Rectified to DC by the full-wave rectifier, resulting in a buzz noise reduction. Size 3 } } 1/8, 1/4, 3/8 Refer to How to Order for the combination of orifice diameter and port size. Reduced apparent power 10 VA m 7 VA (Size 1) Normally Closed (N.C.)

1/4 1/8 C6 (6 One-touch fitting) C8 (8 One-touch fitting) N7 (1/4" Onetouch fitting) N9 (5/16" Onetouch fitting) 1/4 C6 (6 One-touch fitting) C8 (8 One-touch fitting) N7 (1/4" Onetouch fitting) N9 (5/16" Onetouch fitting) C10 (10 Onetouch fitting) N11 (3/8" Onetouch fitting) Port size A, B port Manifold base weight W (g) n: Stations W = 100n + 151 W = 79n + 127 W = 61n + 101 Note 1) For

Maximum load mass m 1 = m/mmax = 1/5 = 0.20 L2 Review m. L1 M2 = m g (L1 + B) 103 2. Static moment m x g = 1 9.8 (50 + 48) 103 Review M2. Since M1 & M3 are not generated, review is unnecessary. = 0.96 [Nm] 2 = M2/M2 max = 0.96/4 = 0.24 M Guide shaft mounting surface L1 B We = 5 x 103 m g U = 5 x 103 1 9.8 300 = 14.7 [N] Me3 = 1/3 We (L2 + A) 103 3.

1/2 2 1 Note 1) For the type with unit switching function [The type without the unit switching function will have a fixed SI unit (l/min, or l, m or m x 10).]

(max. 20 stations) 3 SX3000 5 SX5000 Connector mounting position Symbol Mounting position U U side D D side Valve stations A, B port size Note Symbol 02 Stations SX3000 SX5000 2 stations Port size 4 One-touch fitting 6 One-touch fitting Mixed Symbol Port size 4 One-touch fitting 6 One-touch fitting 8 One-touch fitting Mixed Symbol C4 C6 M Double wiring specification C4 C6 C8 M 08 02 8 stations

How to Order Manifold Assemblies (Example) How to Order Valves Example (SZ3000, positive common with power supply terminals) SZ3 5 1 C6 LOZ 60 Double solenoid SZ3260-5LOZ-C6 (3 sets) Single solenoid SZ3160-5LOZ-C6 (2 sets) Type of actuation Supply/Exhaust block (U side mounting) 1 2 3 4 5 A B C 2 position single solenoid 2 position double solenoid 3 position closed center Switch specifications

The solenoids are counted as Single : 1 point Double, 3P: 2 points Dual 3 port: 2 points Manifold mounting Symbol Mounting DIN rail mount type Direct mount type D E How to Order Valves 1 1 1 Y 5 B C6 Series SQ 3 Manifold block Specifications Without manifold block With manifold block With manifold block Built-in back pressure check valve Symbol Nil Note 1) SQ1000 SQ2000 1 2 M Note 2) Type

Note: 1 Nm = 0.7375 ftlb 1 kg = 2.2046 lb 1 in = 25.4 mm Load (kg) m m m Moment (Nm) F M = F x L M = F x L M = F x L F F L L L 1. Maximum allowable load (1), static moment (2), and dynamic moment (at the time of impact with stopper) (3) must be examined for the selection calculations.

PD0 PD1 PD2 PD3 Flat ribbon cable kit (26P) without cable 1 to 12 stations Flat ribbon cable kit (26P) with 1.5 m cable IP67 compliant (16 stations) Flat ribbon cable kit (26P) with 3.0 m cable LD0 LD1 LD2 Flat ribbon cable kit (26P) with 5.0 m cable Lead wire kit 0.6 m lead wire Lead wire kit 1.5 m lead wire Lead wire kit 3.0 m lead wire 1 to 12 stations (16 stations) 1 to 9 stations PDC

(Station 5) 02 2 stations : : Option Prefix "" mark on valves to be assembled on the manifold. 20 20 stations Write sequentially from the 1st station on the D side None DIN rail mounting DIN rail mounting (Without DIN rail) D DO Uside Dside Stations...3.2...1 A port P1 How to Order Valve VQ M C6 2 1 1 1 G VX VNl Series/Orifice Port size VQ Port size One-touch fitting for 6 One-touch fitting

gases Valve leakage Note 1) 0.1 cm3/min or less (With water pressure), 1 cm3/min or less (Air) Exterior leakage 0.1 cm3/min or less (With water pressure), 1 cm3/min or less (Air) Mounting orientation Upward coil Vibration/Impact Note 2) 30 m/s2 / 90 m/s2 P7, P10 (Quick fastener) C4, C6, C8, C10 (One-touch fitting) Port size Orifice diameter 1, 3, 4.5, 6 Rated voltage 24 VDC, 12 VDC 10% of

side piping: 6 x 4 Detection nozzle: 1.5 Supply pressure: 100 kPa Set distance: 0.15 mm Detection side piping: 6 x 4 Detection nozzle: 2.0 Supply pressure: 100 kPa Set distance: 0.3 mm IF Data 3 1.5 Piping tubing length Piping tubing length 10 m 2.5 10 m 1.2 Response time (sec) Response time (sec) 8 m 2 0.9 5 m 8 m 1.5 0.6 5 m 1 3 m 3 m 0.3 0.5 1 m 0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16

Sum of guide load factors Allowable dynamic moment [MEmax] = + + 1 Load weight [m] Static moment [M] (1) Dynamic moment [ME] (2) 1000 1000 1000 Maximum allowable load [mmax] Allowable static moment [Mmax] Note 1) Moment caused by the load, etc., with cylinder in resting condition.

Regulator Block Stations Stations Symbol 1 2 3 4 5 6 7 8 9 M 1 station 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9 stations 10 stations IN OUT IN OUT 4. IN/OUT Fitting Type (Refer to the figure below.)

Regulator block stations 1 2 3 4 5 6 7 8 9 M 1 station 2 stations 3 stations 4 stations IN OUT OUT IN 5 stations 6 stations 4.

Regulator block stations 1 2 3 4 5 6 7 8 9 M 1 station 2 stations 3 stations 4 stations IN OUT OUT IN 5 stations 6 stations 4.

(A) 4 (A) 4 (B) 2 (B) 2 (Example) SS5YJA7-41-03-01 1 pc. SYJA7140 1 pc. SYJA7240 1 pc. SYJ7000-21-1A 1 pc. 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 3 position exhaust center 3 position closed center (A) 4 (A) 4 (B) 2 (B) 2 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) The asterisk denotes the symbol for assembly.

SYJA3140 1 pc. SYJA3240 1 pc. SYJ3000-21-2A 1 pc. 5(R) 1 (P) (R)3 3(R) 1 (P) 3 position pressure center 3 position pressure center The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. 4(A) (B)2 4(A) (B)2 5(R) 1 (P) (R)3 3(R) 1 (P) Caution Be sure to read this before handling the products.

female threads) ZSM Rc 1/8 Reverse pressure two directions B R 1/8, NPT 1/8 PF2 M5 x 0.8 female threads Panel mount (ZS-22-A) Rc 1/8 IF Data E M5: M5 x 0.8 (Female threads) C4: With 4 One-touch fitting C6: With 6 One-touch fitting Wall mount Wall mount Panel mount + Front protective cover (ZS-24-C) M5 x 0.8 F 4, 6 One-touch fitting Option When optional parts only are required, order