2) 1 1 23 O-ring NBR JISB2401P16 Note 2) JISB2401P16 Note 2) 2 2 24 Seal (A) NBR P36203015 1 P36203015 1 25 Seal (B) NBR P36203016 3 P36203016 3 26 Fixed throttle Stainless steel P36203017 P36202018 1 1 1 1 P36203017 Repair kit no.
Series M3, M5, R 1/8 A hose nipple that provides large holding force for tubing.
Rc1/8 NPT1/8 G1/8 Symbol 3 Actuation Air operated PAF Tube extension Diaphragm material Symbol 1 Material PTFE PA PB P07 P07N P07F Rc1/8 NPT1/8 G1/8 1/4" tube extension Female thread Tube extension Female thread/ Tube extension PB13 3 A P07 1 3 A 1 S PB13 With nut Port size The pump with nut is recommended when SMC fitting, LQ series, is used.
1ode ' , AI fll I j>~[IH'~ I'L l 1-, MM UI INX Al l A, Model JIlor. siz;'4!!1! "041 8 , NO';'o I,LI L, " MM U, I i:/X I f!> I A, ' Y.POO6 I 6 5 6 3g 040 112 3,5 M3XQ,5 5 3 5 I ~POO6 6 5 6 I 3 I-g040 112 3,5 M3 x Q,5 5 3 5 1 4 -1 -11'(51.0,1 '10 $,~ ~o !
Therefore, operate with a silencer (SMC Series AN) mounted on the exhaust port (EXH port). The connection is Rc(PT) 1/2. Precautions for IR100 only Warning 1. When remounting the valve guide after removing it for maintenance, use a tightening torque of no more than 0.6Nm (6kgfcm).
LED 4M12 (5 ) . 8-1 EX245-DY1 56 No.EX-OMU0020CN 8.2. . 8-1 EX245-DY1 (WLH) mm 5412061 280 g PBT DC24 V SI US2 1.6 V 50 mA 4 x M12 5 (2 /) 0.5 A / 1 2 A / 1 1 8 PNP 57 No.EX-OMU0020CN 8.3. M12 5 . 8-2 EX245-DY1 TOP View 1 N.C. 2 2 n+1 3 5 1 3 0 V ( / ) 4 4 ( n) 5 FE/ SI IP65 IP65 8.4.
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: F01 (G1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: R (Bracket for w/o Flow Adjustment Valve: ZS-33-M)
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: F01 (G1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment Valve: ZS-33-M
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
This is a legacy product, and replaced byAL20-F01-A, LUBRICATOR, AIRLINE EQUIPMENT, AL MASS PRO, CA, AL MASS PRO 1/8 MODULAR (PT), .29394 lb, ModelPort SizeDimensionsMounting Bracket Kit (Optional) ACDEFGHJKLMNPQRSTWAL20NPT 1/4401213640?283027225.48.4402.32632M4 X 0.7?AF20P-050AS-X480
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: F01 (G1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate)
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: F01 (G1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: S (Bracket for w/Flow Adjustment
This is a legacy product, and replaced byAR20K-F01-B, REGULATOR, MODULAR, AIRLINE EQUIPMENT, AR MASS PRO, CA, AR MASS PRO 1/8 MODULAR (PT), .62480 lb, Regulator Series ARPages 346 through to 355ModelPort sizeOptionsRegulator with Backflow Function Series AR KPages 346 through to 355AR20K1/8, 1/4BracketSquare embedded type pressure gauge (except the AR10)Round type pressure gauge
This is a legacy product, and replaced byAS2000-F01, SPEED CONTROL (EURO) 1/8 PF, AIRLINE EQUIPMENT, AS 1/8INCH EUROPEAN, .20943 lb
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate)
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: 01 (Rc1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate)
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate)
(MPa): 1, Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2, Number of Outputs: 1, Analog Voltage Output(V): [DC1-5V] 1-5V, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Pipe Connection Direction: 2-way, Connecting Tube Diameter: -, Liquid contact parts material: Resin + Metal, Mounting Hole: Presence,
Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2, Number of Outputs: 1, Analog Voltage Output(V): [DC1-5V] 1-5V, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Pipe Connection Direction: 2-way, Connecting Tube Diameter: 6, Liquid contact parts material: Resin + Metal, Mounting Hole: Presence, Display: