x 0.5 When not equipped with bracket, the M3 threads at both ends (4 positions) can be used for other purposes. (16.3) 11.5 7.7 7.7 11.5 5 22.5 40 7.5 L dimensions n (stations) Dimensions 3 4 6 8 2 9 5 7 10 52.5 L1 70 105 140 35 157.5 87.5 122.5 175 62.5 L2 80 115 150 45 167.5 97.5 132.5 185 69.5 L3 87 122 157 52 174.5 104.5 139.5 192 3 stns. x 1 2 stns. x 2 3 stns. x 2 2 stns. + 3 stns
Terminal block cover 6mm M3 screw Mounting screw (M4) Gasket Electrical entry 4-G1/2 Step 3. How to replace the terminal block cover Securely tighten the screws to the torque shown in the table below, after confirming that the gasket is installed correctly.
Nil Without connector H With connector Compatible drivers Power supply voltage (V) Size 25 32 40 Nil Without driver A1 LECSA1-S 100 to 120 A2 LECSA2-S 200 to 230 B1 LECSB1-S 100 to 120 B2 LECSB2-S 200 to 230 Applicable stroke table Standard C1 LECSC1-S 100 to 120 C2 LECSC2-S 200 to 230 Model Stroke (mm) 100 200 300 400 500 600 700 800 900 1000 S1 LECSS1-S 100 to 120 S2 LECSS2-S 200 to
No.SFOD-OMT0009CN-B 2. 2.1 , 4 4 / 3 2 (SETUP)1 512 2048 I/O 1 4 USB , 7 No.SFOD-OMT0009CN-B 2.2 J X C *3 I/O 1) I/O 1 1.5m 2 1.5m DIN 7 NPN 3 3m 8 PNP 4 3m DIN 4 5 5m 6 5m DIN 7 8 DIN 1)I/O (1.5m~5m) I/O 2 LEY Series LEYG Series LEF Series LES/LESH Series 2) LER Series LEPY/LEPS Series 2 3 LEH Series 2) 360 8 No.SFOD-OMT0009CN-B 2.3 1) PLC I/O 2) :JXC-C2
If the solenoid valve and the manifolds pilot EXH (PE) port is restricted extremely or blocked, abnormal operation of the solenoid valve may occur. 1) When using SMCs M3 or M5 fittings, follow the procedures below to tighten them. Connection thread: M3 First, tighten by hand, then use a suitable wrench to tighten the hexagonal portion of the body an additional 1/4 turn.
Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: A (±1%F.S.), Port Size: M3X0.5
Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: ±1%F.S., Port Size: M3X0.5, Option: -
Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: A (±1%F.S.), Port Size: R04 (Ø4 Plug-In Reducer), Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: A (±1%F.S.), Port Size: IM5H [M5 Female Thread Through Through Type (w/Mounting Hole)], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: A (±1%F.S.), Port Size: M5X0.8, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: A (±1%F.S.), Port Size: R06 (Ø6 Plug-In Reducer), Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: A (±1%F.S.), Port Size: 01 [R 1/8(w/M5 Female)], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: A (±1%F.S.), Port Size: N01 [NPT 1/8 (w/M5 Female Thread)], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: ±1%F.S., Port Size: Ø4 Plug-In Reducer, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: ±1%F.S., Port Size: IM5H [M5 Female Thread Through Through Type (w/Mounting Hole)], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: ±1%F.S., Port Size: M5X0.8, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: ±1%F.S., Port Size: Ø6 Plug-In Reducer, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: ±1%F.S., Port Size: 01 [R 1/8(w/M5 Female)], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: ±1%F.S., Port Size: N01 [NPT 1/8 (w/M5 Female Thread)], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Table 3-1 Amount of radiation and required ventilation Required ventilation amount (m3/min) Heat Differential temp. of 3 C between inside Differential temp. of 6 C between inside radiation Model (kW) and outside of and outside of installation area installation area HRR012-A-10/20Approx.2 40 20 HRR018-A-10/20Approx.4 70 40 HRR024-A-10/20Approx.5 90 50 HRR030-A-10/20Approx.6 100 60 3.2 Installation