Sensor Range: 4 [For Positive Pressure (0~500kPa)], Port Size: N02 [NPT 1/4 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 4 [For Positive Pressure (0~500kPa)], Port Size: 01 [R 1/8 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 4 [For Positive Pressure (0~500kPa)], Port Size: B2 (TSJ 1/4), Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 4 [For Positive Pressure (0~500kPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 4 [For Positive Pressure (0~500kPa)], Port Size: Rc 1/8, Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 4 [For Positive Pressure (0~500kPa)], Port Size: N01 [NPT 1/8 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 4 [For Positive Pressure (0~500kPa)], Port Size: N02 [NPT 1/4 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 4 [For Positive Pressure (0~500kPa)], Port Size: 01 [R 1/8 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 4 [For Positive Pressure (0~500kPa)], Port Size: TSJ 1/4, Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 4 [For Positive Pressure (0~500kPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

differential pressure For low pressure For positive pressure For compound pressure For vacuum URL https://www.smcworld.com Pressure range PSE56# 1473562-4 Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: +81 3-5207-8249 Fax: +81 3-5298-5362 PSE57# ZS-28-CA-4 2-1473562-4 37104-3122-000FL PSE533 PSE543 PSE563 PSE573 PSE530 PSE540 PSE560 PSE570 PSE531 PSE541 PSE561 PSE564

PSE560 and PSE564 are UL/CSA, CE and RoHS compliant, with IP65 enclosure ratings. General purpose remote pressure sensor for liquid or gas at 1 MPa or less; Power supply requirement: 12 to 24 VDC; 1 to 5V or 4 to 20 mA analog output; Accuracy: ±1% of F.S.; Repeatability: ±0.2% of F.S.; Port sizes: 1/8 or 1/4 Rc or NPT (incl. M5 female); 1/8 Rc (female); 1/4 URJ; 1/4 TSJ

PSE560 and PSE564 are UL/CSA, CE and RoHS compliant, with IP65 enclosure ratings. General purpose remote pressure sensor for liquid or gas at 1 MPa or less; Power supply requirement: 12 to 24 VDC; 1 to 5V or 4 to 20 mA analog output; Accuracy: ±1% of F.S.; Repeatability: ±0.2% of F.S.; Port sizes: 1/8 or 1/4 Rc or NPT (incl. M5 female); 1/8 Rc (female); 1/4 URJ; 1/4 TSJ

Sensor Range: 0 [For Positive Pressure (0~1MPa)], Port Size: URJ 1/4, Output Specification: Voltage Output (1~5V) Type, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 3 [For Compound Pressure (-100~100.kPa)], Port Size: URJ 1/4, Output Specification: Voltage Output (1~5V) Type, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: URJ 1/4, Output Specification: Voltage Output (1~5V) Type, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

C2: 2 (SMC) C4: 4 (SMC) 9.1 (C6) 10.3 (C2, C4) D D 3/5 B 2 E 3/5 B 2 B 2 B 2 E B 2 27 (C2, C4) 25.8 (C6) A 4 A 4 A 4 1 P P 1 4 A 4 A S (Pitch of C2, C4) P = 6.5 One-touch fitting [1(P), 3/5(E) port] Applicable tubing: 8 (SMC) (Pitch of C6) P = 9 * Refer to page 97 for dimensions of external pilot and built-in silencer. * Refer to pages 65 to 68, 79, and 80 for dimensions when L6, b, and

) 22.8 10.5 7.4 58.5 39.7 41.8 9.2 22 28.5 22.9 20.4 10.5 8 8 3 x C2, C4, N1, N3 <1(P), 5(EA), 3(EB) port> C2: 2 One-touch fitting C4: 4 One-touch fitting N1: 1/8" One-touch fitting N3: 5/32" One-touch fitting 8.7 With plug connector/light, built-in silencer S0716S-mM(O)-m 16.7 2-Position Double/4-Position Dual 3-Port Grommet: S07 6-mG-m 2 A B C 8 2 x 3.2 5.3 2 x C2, C4, N1, N3 <4(A), 2

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SENSOR, GENERAL FLUID SWITCH, INSTRUMENTATION, PSE200/300/530-560, DX, PSE200/300/530-560 1/4", .00000 lb

C2 H1 CJ1 D FY D B I E CJP AL A MM FX FZ CJ2 K Z H Width across flats NA FT AL A K F S + Stroke H + Stroke ZZ + 2 x Stroke JCM 20 to 32 40 CM2 CM2 CM3 With air cushion CG1 Cushion needle (Width across flats 1.5) 45 WA WA CG3 JMB MB MB1 CA2 Female rod end CS1 Thread depth A1 Female thread MM CS2 3.5 H ZZ + 2 x Stroke (mm) Bore size A AL B B1 B2 C2 D E F FD FL FT FX FY FZ G H H1 H2 I K KA