80, 100 BG 2 x 4 x RT CP96K (D) B CW Bore size Stroke 32, 40 2 x EE 80, 100 80, 100 PL SL PL 2 x EE port D1 Sectional view A-A BG 2 x 4 x RT PL Cushion valve WB WA Width across flats SW WA WB A KK B B D KK E R A 2 x 4 x RT L2 BG L9 VD ZY + 2 x Stroke H + Stroke L8 + Stroke H A WH G G WH + Stroke A L2 BG VD L12 E R * Mounting brackets are the same as standard type.
BG L9 80, 100 ZZ + Stroke L8 + Stroke H VA G 2 x 4 x RT BG C96K (D) B CW Bore size Stroke 32, 40 2 x EE 80, 100 80, 100 D1 PL 2 x EE port SL PL 2 x 4 x RT Sectional view A-A BG Cushion valve PL WA WB Width across flats SW A KK B B D KK WA WB A ZY + 2 x Stroke H L8 + Stroke H + Stroke WH + Stroke A G G WH A L2 BG VD 2 x 4 x RT L12 L2 BG VD L9 E R * Mounting brackets are the same as standard
Grease pack part number: GR-S-010 (10 g), GR-S-020 (20 g) 16 CP96N Series Dimensions (Double Rod) GD2 GB EE Rod side cylinder port EE Head side cylinder port Basic: CP96NB-W GC GA GD1 GC GD2 GB WA2 WB2 PL 2 x 4 x RT BG WB2 WA2 WA1 WB1 GA BP GF 32 80, 100 Manual lock release bolt Width across flats KC Cushion valve BP Unlocked when pressurized 4 x RT Thread depth BG L2 E1 R V Width across
. *1 Since the nuts are embedded in the SUP/EXH block wD-sub connector block
HUMIDITY SWITCH, HUMIDITY SENSOR, Q62, 152.00000 lb
HUMIDITY SWITCH, HUMIDITY SENSOR, Q62, 142.00000 lb
HUMIDITY SWITCH, HUMIDITY SENSOR, Q62, 142.00000 lb
HUMIDITY SWITCH, HUMIDITY SENSOR, Q62, 142.00000 lb
RY RT (mm) Stroke range (mm) A Bore size (mm) 40 50 63 80 100 AL B B1 C D E F G H1 J K KA LD LH LS LT With rod boot Without rod boot 20 to 800 Up to 800 30 27 60 22 44 16 32 10 15 8 M8 x 1.25 6 14 9.0 40 138 3.2 Up to 1200 20 to 1200 35 32 70 27 52 20 40 10 17 11 M8 x 1.25 7 18 9.0 45 144 3.2 Up to 1200 20 to 1200 35 32 85 27 64 20 40 10 17 11 M10 x 1.25 7 18 11.5 50 166 3.2 20 to 1400 Up
Grease pack part number: GR-S010 (10 g), GR-S-020 (20 g) 59 Series C96 Dimensions Bore size Stroke Basic: C96S(D)B SW PL 2 x EE PL KK WA B D B R E WB Cushion valve 8 x RT VD L9 BG L2 L12 A WH G H G L8 + Stroke VA ZZ + Stroke R E With rod boot e d f l h h + L8 + VA + Stroke Stroke range (mm) A B d11 D EE PL RT L12 KK SW G BG L8 VD VA WA WB WH ZZ E R Bore size (mm) Without rod boot With rod
R GL WB C85 GL 1 T BG 4 x RT 4 x RT C76 VA I9 VD V H1 VB BG H1 Q GF GE CG1 I12 F AM I12 AM BN 2 G WH 18 H + Stroke H + Stroke ZY + Stroke MB MB1 CP95 C95 C92 Be 11 46 52 65 75 95 114 Bore size (mm) B AM BP BN D EE GE BG GL 1 H 2 E1 GF H F GL E G GA GC GD 1 18.3 19.5 22.4 20.7 26 26 6 8 11 11 13 16 48 54 69 69 86 91 97 104 120.5 134.5 169 189 12 16 20 20 25 30 16 16 16 16 16 16 88.5 96.5 111.2
G AL F B1 4 x J MM H1 RY D E d e B C LY 4 x LD LH Width across flats KA RT N N LT LX L 10.2 f X X S + Stroke C h + L LS + Stroke Y Y B ZZ + L + Stroke ZZ + Stroke (mm) Bore size Stroke range (mm) A AL B B1 C D E F G H1 J K KA LD LH LS LT LX LY (mm) 40 50 63 80 30 35 35 40 40 27 32 32 37 37 60 70 85 22 27 27 32 41 44 52 64 78 92 16 20 20 25 30 32 40 40 52 52 10 10 10 14 14 15 17 17 21 21 8
Note 5) Value with the rated load, facility water flow rate at rated flow rate and the facility water inlet pressure 0.2 MPa Note 6) Value with the rated load (1 RT = 4.535 kW) Note 7) Value with the power supply voltage 200 V Note 8) Install a circuit breaker with a sensitivity 30 mA.
Bore size (mm) Stroke range (mm) RT RY 32 58 28 1401 to 1800 RY 40 65 28 1401 to 1800 50 75 33 1401 to 1800 63 90 43 1501 to 1800 80 100 The maximum stroke is 1500mm for series CH2G only.
0.7 Inlet air temperature [C] 40 Ambient temperature [C] 32 Outlet air pressure dew point [C] 10 Air dryer outlet air temperature [C] 37 Facility water flow rate *4 (50/60 Hz) [m3/h] 1.29/1.56 1.74/1.98 2.16/2.52 Facility water inlet temperature [C] 32 Rated conditions Refrigerant R407C (HFC) IDF E Facility water pressure drop *5 (50/60 Hz) [MPa] 0.07/0.1 Cooling tower capacity *6 [kW(RT
Curved type Air supply unit Note 1) RS RT RG Lateral curve Inside curve Outside curve Qty. None 1 set 2 sets Description Symbol Nil AS AW Angle A unit (Air system 1) 45 90 180 45 90 180 Note 1) Air supply unit, 1 set breakdown: Supply block (slide table side) 1pc. Supply ring (plate side) 2pcs.
Output Specification: L2 (IO-Link/Switch output 1 + Switch output 2), Units specification: w/Units Selection Function, Piping Specification: 01 (R 1/8)
S + Stroke ZZ + Stroke LS + Stroke MLGC CNG With rod boot MNB 75 CNA CNS 40 l h + l ZZ1 + l + Stroke CLS Long stroke CLQ Rc BQ plug with breathing hole BC element 4 x J CL 2 x MA Thread effective depth R RLQ AL FA A K H GA F GB BP (Rc, NPT, G) Unlocking port GR GL T G G 2 x P (Rc, NPT, G) Cylinder port MM MLU Q MLGP D EA RY E LY LH ML1C V 4 x LD Width across flats KA VA BN S + Stroke N RT
Stations mTr rt t*. lT' 20 | 20 stations lpllrih llnlr Jrb dI vJ3000-21-1A A,B port Type 46 & 546 (for 5 port base mounted type) Appllcable valves NVJ30400-O NVJ30430-O Itdi.
Stations mTr rt t*. lT' 20 | 20 stations lpllrih llnlr Jrb dI vJ3000-21-1A A,B port Type 46 & 546 (for 5 port base mounted type) Appllcable valves NVJ30400-O NVJ30430-O Itdi.