Mounting with bracket Mount the bracket on the body with two M3 x 5L mounting screws. Tighten the bracket mounting screws at a tightening torque of 0.5 to 0.7 Nm. Wiring Caution M3 x 5L 1. Connection and removal of sensor connector Hold the lever and connector body with two fingers and insert the connector straight into the pin until it is locked with a click sound.
Voltage: 5 (24VDC), Electrical Entry: M (M Plug Connector), Lead Wire: O (w/o Lead Wire), Orifice Size: 03 (0.3mm), Port Size: w/o Sub-Plate w/Mounting Screw, Body/Seal Material: A (Body C36, Seal FKM)
Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: DC24V, Specification: Standard / Low Vacuum Compatible, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: -, Port Size: -, Pressure Rating(MPa): 0 to 1.0, Driving Type: Linear Motion Poppet,
Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: DC12V, Specification: Standard / Low Vacuum Compatible, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: -, Port Size: -, Pressure Rating(MPa): 0 to 1.0, Driving Type: Linear Motion Poppet,
Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: DC12V, Specification: Standard / Low Vacuum Compatible, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: -, Port Size: -, Pressure Rating(MPa): 0 to 1.0, Driving Type: Linear Motion Poppet,
Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector), Lead Wire: O (w/o Lead Wire), Orifice Size: 03 (0.3mm), Port Size: w/o Sub-Plate w/Mounting Screw, Body/Seal Material: A (Body C36, Seal FKM)
Voltage: 24VDC, Electrical Entry: L Plug Connector, Lead Wire: w/o Lead Wire, Orifice Size: 0.3mm, Port Size: w/o Sub-Plate w/Mounting Screw, Body/Seal Material: Body C36, Seal FKM
Voltage: 6 (12VDC), Electrical Entry: L (L Plug Connector), Lead Wire: O (w/o Lead Wire), Orifice Size: 03 (0.3mm), Port Size: w/o Sub-Plate w/Mounting Screw, Body/Seal Material: A (Body C36, Seal FKM)
Voltage: 6 (12VDC), Electrical Entry: L (L Plug Connector), Lead Wire: Lead Wire, Orifice Size: 03 (0.3mm), Port Size: w/o Sub-Plate w/Mounting Screw, Body/Seal Material: A (Body C36, Seal FKM)
Voltage: 6 (12VDC), Electrical Entry: M (M Plug Connector), Lead Wire: Lead Wire, Orifice Size: 03 (0.3mm), Port Size: w/o Sub-Plate w/Mounting Screw, Body/Seal Material: A (Body C36, Seal FKM)
Voltage: 5 (24VDC), Electrical Entry: M (M Plug Connector), Lead Wire: Lead Wire, Orifice Size: 03 (0.3mm), Port Size: w/o Sub-Plate w/Mounting Screw, Body/Seal Material: A (Body C36, Seal FKM)
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
Insert a 4 tube (with inside diameter of 2.5) into the atmospheric release port and pipe the other end to a place with no spattering water or other liquid. Do not fold or clog the tube or the pressure cannot be measured properly. 2. Mounting with brackets Mount a bracket to the using two M3 x 5L mounting screws and install on piping with a hexagon socket cap screws.
VS7
Effective orifice(mm2 Weight (g) ) I H G F D E B C A 15 16 7 8 5.5 6 6.5 8.5 1.8 2.5 12 13.5 8.5 9.5 7 8 15.5 17.5 M-5HLH-4 M-5HLH-6 1.4 4.5 6.6 2.4 Elbow: M-5L Tee: M-5T Weight: 4.2g Weight: 3.5g Universal elbow: M-5UL Universal tee: M-5UT Effective orifice: 2.4mm 2 Weight: 5.3g Effective orifice: 2.4mm 2 Weight: 4.8g Extention fitting: M-5J Nipple: M-5N 303 Stainless Steel Effective orifice
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard / Low Vacuum Compatible, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: M, Port Size: M5, Pressure Rating(MPa): 0 to 1.0, Driving Type: Linear Motion Poppet, Seal Type: Soft Seal
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC12V, Specification: Standard / Low Vacuum Compatible, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: M, Port Size: M5, Pressure Rating(MPa): 0 to 1.0, Driving Type: Linear Motion Poppet, Seal Type: Soft Seal
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC12V, Specification: Standard / Low Vacuum Compatible, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: M, Port Size: M5, Pressure Rating(MPa): 0 to 1.0, Driving Type: Linear Motion Poppet, Seal Type: Soft Seal
Voltage: 6 (12VDC), Electrical Entry: M (M Plug Connector), Lead Wire: Lead Wire, Orifice Size: 03 (0.3mm), Port Size: M5 (w/Sub-Plate M5x0.8), Body/Seal Material: A (Body C36, Seal FKM)