The load kinetic energy can be obtained by the following equation: 5 a 1 Rush speed into cushion (mm/s) 100 50 200 500 750 M Also, selection can be made by using the graph above. Example) Find the maximum load weight when using a cylinder with 32, stroke 500 mm, with rear plate as a lifter at an average speed of a 300 mm/s.
Intermediate stroke Strokes Bore size 550 600 350 400 450 500 175 200 225 250 275 300 325 375 425 475 525 575 650 700 750 800 850 900 950 1000 150 REAH10 RE H15 REAH20 RE H25 RE HT25 RE HT32 A B A B A B A B : Standard stroke : Strokes set for -XB10 : No setting -X -X 1737 Made to Order Common Specifications: -XB10A: Intermediate Stroke (Spacer-installed type) Symbol -XB10A Intermediate
Series Dimensions IDF190D, IDF240D Ventilation direction Port size (JIS 10K FF) D A 100 B (80) Ventilation air inlet Compressed air inlet Ventilation direction Ventilation direction E F C Power connection Grommet with membrane (Pilot hole 36) Compressed air outlet Drain outlet Rc1/2 J 200 G H I 4 x 20 [mm] Model Inlet and outlet port A B C D E F G H I J IDF190D JIS 10K FF 80 (3B) Flange 750
Nil Without cable H Without cable (Connector only) 1 1.5 Applicable Stroke Table : Standard Stroke [mm] Manufacturable 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 stroke range Model [mm] LEFS25 50 to 600 LEFS32 50 to 800 LEFS40 150 to 1000 * When the driver type is selected, the cable is included. Select cable type and cable length.
Lead wire and connector Model Width across flats of attachment Hysteresis mode 2 Piping port (IN side) : This drawing is the model of PF2A710/750.
Up to 750 With rod boot ZZ Bore (mm) Applicable pin part no.
130 40 37 32 100 50 25 82 11 9 28 20 71 13 89 M10 x 1.5 10 22 7 M22 x 1.5 80 3/8 210 100 to 750 110 10 131 40 37 41 125 60 30 100 14 10 29 20 71 16 M12 x 1.75 26 8 M26 x 1.5 100 1/2 212 Flange brackets and plug bolts are installed before shipment from factory.
Data PSE561 PSE560 PSE563 PSE564 Model 0 to 101 kPa 0 to 1 MPa 0 to 500 kPa 100 to 100 kPa 500 kPa Rated pressure range 1.5 MPa 750 kPa 500 kPa Proof pressure Model PSE56--28 PSE56Fluid Fluid, including gas, that will not corrode Stainlesss steel 316L Power supply voltage 12 to 24 VDC 10%, Ripple (p-p) 10% or less (With power supply polarity protection) 10 mA or less Current consumption
15, 25 CY CY1H CY1F MG Standard stroke (mm) Maximum stroke Cushion Piping directions Bore size (mm) Model Height Overall length mm mm 150 200 250 300 350 400 450 500 550 600 50 100 CX 10 15 25 15 10 25 240 350 310 For 100mm stroke cylinder Series Series 10 500 CY1F CY1H CY1F CY1H MY2H Concentrated piping on right 28 34 46 46 63 198 225 205 294 260 DBuilt-in shock absorber 39.5 CY1F 15 750
Vertical Operation CY1L CY1L CY1L6 CY1L6 1 0 500 (650) 750 1000 1500 Bore size (mm) Allowable load mass (Wv) (kg) 1.53 1.6 + Lo CY1H Cylinder stroke (mm) 6 5.00 1.95 + Lo CY1F 10 15.96 2.4 + Lo 15 CYP 31.1 2.8 + Lo 54.48 3.1 + Lo 20 25 112.57 3.95 + Lo 212.09 4.75 + Lo 32 40 DLo: Distance from mounting surface to load center of gravity (cm) Note) Operating pressure should be
750 750 850 850 6 9 9 9 12 12 12 16 16 460 665 693 693 1162 1162 1162 1416 1416 19 19 19 19 19 19 19 27 27 80 M16 x l 250 M16 x l 250 M16 x l 250 M16 x l 300 M16 x l 300 M16 x l 300 M16 x l 500 M24 x l 500 M24 x l 500 AT6C AT11C AT22C AT37C AT55C AT75C AT125C AT150C AT220C 1 2 Rc 1/2 Rc 3/4 Rc 1 Rc 1 Rc 1 1/4 Rc 1 1/4 Rc 2 Rc 2 Rc 2 Rc 110 110 110 180 180 180 260 260 Rc 3 4 Rc 1 1 2 1 2
When the piston speed exceed 750 mm/s, make sure that direct impact does not apply on the cylinder cover by using an external stopper (shock absorber, etc). Standard external (B) 17 25 35 36 46 60 70 86 100 Dimensions except mentioned above are the same as standard type.
Area: (800) 258-9200-www.stevenengineering.com Piping directions Maximum stroke Cushion Bore size (mm) Model Height Overall length mm mm 150 200 250 300 350 400 450 500 550 600 50 100 CX 10 15 25 15 10 25 240 350 310 For 100mm stroke cylinder Series Series 10 500 CY1F CY1H CY1F CY1H MY2H Concentrated piping on right 28 34 46 46 63 198 225 205 294 260 DBuilt-in shock absorber 39.5 CY1F 15 750
6 to 400 24 to 1200 16 to 800 8 to 400 30 to 1200 20 to 850 10 to 300 Speed*1 [mm/s] 501 to 600 30 to 1200 20 to 850 10 to 300 Actuator specifications Parallel Stroke range Up to 500 20 to 900 12 to 600 6 to 300 24 to 800 16 to 650 8 to 325 30 to 750 20 to 550 10 to 300 501 to 600 30 to 750 20 to 550 10 to 300 Max. acceleration/deceleration [mm/s2] 3000 Positioning repeatability [mm] 0.01
T dimension) 0 1 5 None Differential pressure indicator Differential pressure indication switch Note) 1 2 3 4 5 1 2 3 4 1 2 3 4 340 410 480 550 620 430 530 630 730 560 650 750 850 04 (1/2B) 06 (3/4B) 08 (1B) 30 FH FH Note) N.C. and N.O. common Note) When the differential pressure indication 1 or 5 is selected, the connection method is 2 to 5. (0 and 1 cannot be selected.)
Standard Stroke Maximum stroke available (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.
Models/Specifications MHS3-16D MHS3-20D MHS3-25D MHS3-32D MHS3-40D MHS3-50D MHS3-63D MHS3-80D MHS3-100D MHS3-125D Model Cylinder bore size (mm) 16 20 25 32 40 50 63 80 100 125 Air Fluid Operating pressure (MPa) 0.2 to 0.6 0.1 to 0.6 Ambient and fluid temperature (C) 10 to 60 0.01 Repeatability (mm) 60 Max. operating frequency (c.p.m.) 120 30 Not required Lubrication Double acting Action 25 750
Maximum acceleration: 2000mm/s Positioning time (sec.) 1500 750 100 10 1 Positioning distance (mm) 151.1 76.1 11.1 2.1 1.2 10 16.1 8.6 2.1 1.2 1.1 100 Speed (mm/s) The value is a guide when SMC's series LCI controller is used and may vary depending on the driver capacity. 7.2 4.2 1.6 1.2 1.1 250 4.3 2.8 1.5 1.2 1.1 500 Values will vary slightly depending on the operating conditions.
OUT1OUT2OUT3OUT4OUT5 AC100~240V Pulse counter M/C Flow control for each branch line For Air P.2 50l/min 10l/min 500l/min 200l/min 100l/min 12000l/min 6000l/min 3000l/min Flow rate measurement range l/min Integrated display type Remote type Output specifications Port size (Rc, NPT, G) 1/8 1/4 3/8 1/2 11/2 1 2 Switch output Analog output Accumulated pulse output Display unit Sensor unit PF2A710 750
Rc NPT G Symbol N M12 3 m lead wire with connector Without lead wire Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l Port size Output specification Port size Applicable model Flow rate (l/min) Symbol Symbol Output specification 100 200 500 50 10 01 02 03 04 1/8 1/4 3/8 1/2 27 NPN open collector 2 outputs PF2A710/750 PF2A711/721 PF2A751 67 PNP open collector 2 outputs