Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 1 (Connector Top Direction), Stations: 10 Stations, SUP/EXH Block Mounting: U (U Side 2~10 Stations), Pilot: Internal Pilot, A, B Port: C10 (ø10 One-touch Fitting)
Type of Connector: D-sub Connector 25 Pin, Connector Outlet Direction: Connector Top Direction, Stations: 4 Stations, SUP/EXH Block Mounting: U Side 2~10 Stations, Pilot: Internal Pilot, Built-in Silencer, A, B Port: 3/8" One-touch Fitting, Mounting Method: DIN Rail Mounting
Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 1 (Connector Top Direction), Stations: 4 Stations, SUP/EXH Block Mounting: U (U Side 2~10 Stations), Pilot: S (Internal Pilot, Built-in Silencer), A, B Port: N11 (3/8" One-touch Fitting), Mounting Method: D (DIN Rail Mounting)
= P x S x 0.1 x 1/t W = 1 g = 0.0098 N 0.0098 = P x 0.13 x 0.1 x 1/4 S = P/4 x (0.4)2 = 0.13 cm2 P = 3.0 kPa t = 4 (Horizontal lifting) According to the calculation, 3.0 kPa or more of vacuum pressure can adsorb the workpiece. (3) Based on the workpiece shape and type, select: Pad type: Flat Pad material: Silicone (4) According to the results above, select a vacuum pad part number ZP3-04US
= P x S x 0.1 x 1/t W = 1 g = 0.0098 N 0.0098 = P x 0.13 x 0.1 x 1/4 S = P/4 x (0.4)2 = 0.13 cm2 P = 3.0 kPa t = 4 (Horizontal lifting) According to the calculation, 3.0 kPa or more of vacuum pressure can adsorb the workpiece. (3) Based on the workpiece shape and type, select: Pad type: Flat Pad material: Silicone (4) According to the results above, select a vacuum pad part number ZP3-04US
= P x S x 0.1 x 1/t W = 1 g = 0.0098 N 0.0098 = P x 0.13 x 0.1 x 1/4 S = P/4 x (0.4)2 = 0.13 cm2 P = 3.0 kPa t = 4 (Horizontal lifting) According to the calculation, 3.0 kPa or more of vacuum pressure can adsorb the workpiece. (3) Based on the workpiece shape and type, select: Pad type: Flat Pad material: Silicone (4) According to the results above, select a vacuum pad part number ZP3-04US
Type of Connector: D-sub Connector 25 Pin, Connector Outlet Direction: Connector Top Direction, Stations: 6 Stations, SUP/EXH Block Mounting: Both Sides 2~20 Stations, Pilot: Internal Pilot, A, B Port: ø10 One-touch Fitting, Mounting Method: DIN Rail Mount w/o DIN Rail
Type of Connector: D-sub Connector 25 Pin, Connector Outlet Direction: Connector Top Direction, Stations: 2 Stations, SUP/EXH Block Mounting: D Side 2~10 Stations, Pilot: Internal Pilot, A, B Port: ø10 One-touch Fitting, Mounting Method: DIN Rail Mounting
Type of Connector: D-sub Connector 25 Pin, Connector Outlet Direction: Connector Top Direction, Stations: 9 Stations, SUP/EXH Block Mounting: Both Sides 2~20 Stations, Pilot: Internal Pilot, Built-in Silencer, A, B Port: ø10 One-touch Fitting, Mounting Method: DIN Rail Mounting
Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 1 (Connector Top Direction), Stations: 6 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: Internal Pilot, A, B Port: C10 (ø10 One-touch Fitting), Mounting Method: D0 (DIN Rail Mount w/o DIN Rail)
Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 1 (Connector Top Direction), Stations: 2 Stations, SUP/EXH Block Mounting: D (D Side 2~10 Stations), Pilot: Internal Pilot, A, B Port: C10 (ø10 One-touch Fitting), Mounting Method: D (DIN Rail Mounting)
Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 1 (Connector Top Direction), Stations: 9 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: S (Internal Pilot, Built-in Silencer), A, B Port: C10 (ø10 One-touch Fitting), Mounting Method: D (DIN Rail Mounting)
Stations: 4 Stations, SUP/EXH Block Mounting: U Side 2~10 Stations, Pilot: Internal Pilot, Built-in Silencer, A, B Port: 3/8" One-touch Fitting, Mounting Method: -
SI Unit: DeviceNet, PROFIBUS-DP, EtherNet/IP, Stations: 4 Stations, SUP/EXH Block Mounting: U Side 2~10 Stations, Pilot: Internal Pilot, Built-in Silencer, A, B Port: NPTF3/8, Mounting Method: -
SI Unit: DeviceNet, PROFIBUS-DP, EtherNet/IP, Stations: 4 Stations, SUP/EXH Block Mounting: U Side 2~10 Stations, Pilot: Internal Pilot, Built-in Silencer, A, B Port: ø12 One-touch Fitting, Mounting Method: -
Type: Base for Manifolds, Communication Protocol: N/A, Output Format: -, Type: Multi-Connector Compatible Tie-Rod Base Manifold, Number of Inputs/Outputs: -, Connector: N/A, Mounting Method: Direct mounting, Port pipe connection port diameter: NPTF3/8 (A-, B-Port), NPT3/8 (P-, E-Port), Specification: Internal pilot, Silencer built-in, Applicable valve: SV4000, P- and E-port entry position
Stations: 4 Stations, SUP/EXH Block Mounting: U (U Side 2~10 Stations), Pilot: S (Internal Pilot, Built-in Silencer), A, B Port: N11 (3/8" One-touch Fitting)
Stations: 4 Stations, SUP/EXH Block Mounting: U (U Side 2~10 Stations), Pilot: S (Internal Pilot, Built-in Silencer), A, B Port: 03T (NPTF3/8)
Model: 11S (Bottom Ported), SI Unit Specification: 0 (w/o SI Unit), SI Unit Ouput Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 4 Stations, P,E Port Entry: U (U Side, 2 to 10 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C10 (ø10 One-touch Fitting, Straight, Metric)
Model: 10 (Side Ported), Connector Type: F (D-sub Connector, IP40, 25 Pins), Connector Entry Direction: 2 (Lateral), Valve Stations: 4 Stations, P,E Port Location: U (U Side, 2 to 10 Stations), SUP/EXH Block: S (Internal Pilot, built-in Silencer), A,B Port Size: C10 (ø10 One-touch Fitting)