W1 B DX Z + Stroke DDH10 hole 90 B 4-DT B DS A DH DF DU DU DL DA 4-DR DO DO DC DE Rotating Angle Bore size (mm) 40 50 63 80 100 Bore size (mm) 40 50 63 80 100 Part no.
CE CF DL CL DA DB CA CB CDH10 (mm) DDH10 (mm) CJ 7 10 10 14 CI 17 22 27 32 CH 11 13 13 17 CF 4 7 10 12 CE 3.5 3.5 3.5 5.5 CB 23 27 31 37 CA 53 67 85 103 DJ 7 10 10 14 DI 17 22 27 32 DH 11 13 13 17 DF 4 7 10 12 DE 3.5 3.5 3.5 5.5 DB 23 27 31 37 DA 53 67 85 103 Size 25 32 40 50 Size 25 32 40 50 Part no.
Bore size (mm) DA DL DU DC DX DE DO DR DT DS DH DF B Z DDH10 (Hole) CA2-B04 40 57 35 11 65 15 85 10 9 17 8 40 52 60 165 10 +0.058 0 CA2-B05 50 57 35 11 65 18 85 10 9 17 8 40 52 70 183 12 +0.070 0 CA2-B06 63 67 40 13.5 80 25 105 12.5 11 22 10 50 66 85 196 16 +0.070 0 CA2-B08 80 93 60 16.5 100 31.5 130 15 13.5 24 12 65 90 102 235 20 +0.084 0 CA2-B10 100 93 60 16.5 100 35.5 130 15 13.5 24 12
When connected to EX600-DE or EX600-DF, manifold enclosure is IP40. Also, the Handheld Terminal conforms to IP20, so prevent foreign matter from entering inside, and water, solvent or oil from coming in direct contact with it. 2. Provide adequate protection when operating in locations such as the following. Failure to do so may cause damage or malfunction.
Temperature N1 P1 Q1 R1 R2 R3 S1 T1 U1 Main valve: Indicator/ Pilot port direction Symbol Nil Without indicator Kalrez Number of auto switches/Mounting position Symbol Nil Without auto switch 2 pcs. 1 pc. 1 pc.
CQ2 series Stroke S2 Part no. denotation B Stroke S1 Part no. denotation A Stroke S2 Part no. denotation B Stroke S1 Part no. denotation A B + Stroke S2 L B + Stroke S1 L B + Stroke S2 L L B + Stroke S1 A + Stroke (S1 + S2) A + Stroke (S1 + S2) Note) In the case of bore sizes 12 to 25 with auto switch, port directions are different.
Q1 R1 R2 R3 S1 T1 Kalrez 4079 SS592 SS630 SSE38 1232-70 3310-75 Chemraz Example) XLH-16-XAN1A VMQ FKM for Plasma ULTIC ARMOR U1 UA4640 Produced by Mitsubishi Cable Industries, Ltd.
CDRBU2W10, 15-S CDRBU2W20, 30-S CRB2 CRBU2 CRB1 2 x S2 2 x S1 2 x S1 MSU 2 x S2 CRJ Rotary actuator CRA1 CRQ2 2 x S1 2 x S1 2 x S1 2 x S1 Rotary actuator MSQ (34.5: Connector type) MSZ A port B port CRQ2X MSQX 2 x R A port B port 2 x R MRQ 1 Auto switch Auto switch 2 5 20.5 (26.5: Connector type) 1.
Series CQ2 Stroke S2 Part no. denotation B Stroke S1 Part no. denotation A Stroke S2 Part no. denotation B Stroke S1 Part no. denotation A Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com B + Stroke S2 B + Stroke S1 B + Stroke S2 B + Stroke S1 A + Stroke (S1 + S2)
S2 R1 R2 SG FG 24 V 0 V S1 S2 SG 24 V 0 V S1 S2 R1 R2 SG FG 24 V 0 V S1 S2 R1 R2 SG FG 24 V 0 V Ground either the reception side or the transmission side of the shielding wire shield.
S2 S3 S0 S1 S2 S3 U0 U1 U2 U3 S0 S1 S2 S3 Without cable Without cable Without cable (2) Max. 16 stations (2) Max. 16 stations (2) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) Max. 16 stations Kit P Kit P Kit J Kit J Kit F Kit F L S The valve is equipped with an indicator light
8 9 A B C D E F 1 4.1 + *S2 S1 DC24V MADE IN JAPAN 2 3 4 (48.5) (50) 133 10.5 10.5 5.1 4.5 5 5 Models Output unit can be used for mixed connection with PCW series.
S2 S1 S2 S1 S2 S1 Master unit V BDH SD FG SD FG SD FG SD FG CANL Twisted pair wire with shield FG BDL Class 3 ground Class 3 ground Class 3 ground Class 3 ground CANH V+ Connect the shielding wire to the SD terminal.
flow rate adjusting needle (PE port) Interface plate 63.5 18 4 15.5 2-3.3 Mounting hole M5 (or M6) (V port) Vacuum pad connection port M5 (or M6) (PV port) Air supply pressure port Bracket A (Standard accessory) Note) Dimensions : For mounting bracket A : For mounting spacer 1. 13-2-26 26 Vacuum Module: Ejector System Series ZX Adsorption confirmation switch (ZSP1) ZX1-K8-P Spacer 1: ZX1-S1
flow rate adjusting needle (PE port) Interface plate 63.5 18 4 15.5 2-3.3 Mounting hole M5 (or M6) (V port) Vacuum pad connection port M5 (or M6) (PV port) Air supply pressure port Bracket A (Standard accessory) Note) Dimensions : For mounting bracket A : For mounting spacer 1. 13-2-26 26 Vacuum Module: Ejector System Series ZX Adsorption confirmation switch (ZSP1) ZX1-K8-P Spacer 1: ZX1-S1
Kit/Electrical entry/Cable length F P Kit (Dsub connector) Kit (Flat cable connector) Connector location Top (vertical) Side (horizontal) Connector location Top (vertical) Side (horizontal) P .1.10-40 P .1.10-36 Without cable Without cable S0 S1 S2 S3 S0 S1 S2 S3 U0 U1 U2 U3 U0 U1 U2 U3 stations Max.16 (2) Max.16 (2) F kit P kit P kit F kit With cable (1.5m) With cable (3m) With cable (5m
Connector location Connector location P.1.10-124 P.1.10-128 P.1.10-132 Top (vertical) Side (honzontal) Top (vertical) Side (honzontal) Without cable With cable (1.5m) With cable (3m) With cable (5m) Without cable Without cable F F S0 S1 S2 S3 P P S0 S1 S2 S3 S0 S1 S2 S3 U0 U1 U2 U3 U0 U1 U2 U3 U0 U1 U2 U3 0 1 2 3 (2) (2) (2) G 2 to 16 stations With cable (1.5m) With cable (3m) With cable
New Products Guide 2 Air Preparation Equipment, Modular F. R. L., Air Tanks Fittings and Tubing Flow Control Equipment, Exhaust Filters Switches/Sensors Process Valves High Vacuum Equipment Temperature Control Equipment Pneumatic Instrumentation Process Gas Equipment Equipment CAT.E00-7A INDEX New Products Guide 2 Air Preparation Equipment/ Modular F. R. L./Air Tanks Refrigerated Air Dryer
U S1 [mm] Size S1 T2 U 25 47 91 1 32 61 117 1 63 84 142 4 T2 T2 Note) When the motor is mounted on the left or right side in parallel, the groove for auto switch on the side to which the motor is mounted is hidden. 12 Series LEY Dimensions: In-line Motor Encoder Z-phase detecting position F1 Note 1) Rod operating range (Stroke + G mm) Z D T EV M J U 4 x O1 thread depth R M K Note 2) V W
1 I/O cable length [m]*3 Compatible driver Power supply voltage [V] Size 25 32 40 Nil Without driver A1 LECSA1-S100 to 120 A2 LECSA2-S200 to 230 B1 LECSB1-S100 to 120 B2 LECSB2-S200 to 230 C1 LECSC1-S100 to 120 C2 LECSC2-S200 to 230 S1 LECSS1-S100 to 120 S2 LECSS2-S200 to 230 *3 When Without driver is selected for driver type, only Nil: Without cable can be selected.