For saturated steam Viewing the graph [664] (183) Upstream pressure of valve P1 = 1.0MPa 1.0 The sonic range pressure to generate a flow rate of 25kg/h for orifice 3 (VCS21) is P1 approx. 0.68MPa for orifice 4 (VCS21) is P1 approx. 0.40MPa for orifice 5 (VCS21) is P1 approx. 0.29MPa The holding heat differs somewhat depending on the pressure P1, but at 25kg/h it is approximately 16000kcal

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S.), Air Pressure

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S.), Air Pressure

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S.), Air Pressure

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S.), Air Pressure

Main Body Shape: Unit, Additional Function: -, Ultimate Vacuum(kPa): -74, Air Consumption Flow Rate(l/min): 12, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø3.2, Air Supply Port Connecting Shape: M3, Air Supply Port One-Touch Fitting Size: -, Application: Individual Item, Operating Pressure Range(MPa): 0.2~0.5, Operating Temperature Range(°C

Main Body Shape: Unit, Additional Function: -, Ultimate Vacuum(kPa): -74, Air Consumption Flow Rate(l/min): 12, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø4, Air Supply Port Connecting Shape: M3, Air Supply Port One-Touch Fitting Size: -, Application: Individual Item, Operating Pressure Range(MPa): 0.2~0.5, Operating Temperature Range(°C):

Main Body Shape: Unit, Additional Function: -, Ultimate Vacuum(kPa): -74, Air Consumption Flow Rate(l/min): 12, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø4, Air Supply Port Connecting Shape: -, Air Supply Port One-Touch Fitting Size: -, Application: Manifolds, Operating Pressure Range(MPa): 0.2~0.5, Operating Temperature Range(°C): 5:50~,

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: Supply: NC, Release: NC, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S., Air Pressure Supply, P Port

Item Classification pD(Torrcm) /D (Knudsen number) >0.5 <0.01 Viscous flow 0.5 to 0.015 0.01 to 0.3 Intermediate flow <0.015 >0.3 Molecular flow 8 Exhaust time (low/medium vacuum) 4 5 1 2 3 4 1 2 3 The time (gt) required to exhaust a chamber at low vacuum with volume V (l), from pressure P1 to P2, using a pump with pumping speed S (l/sec) is gt=2.3(V/S)log(P1/P2).

Item Classification pD(Torrcm) /D (Knudsen number) >0.5 <0.01 Viscous flow 0.5 to 0.015 0.01 to 0.3 Intermediate flow <0.015 >0.3 Molecular flow 8 Exhaust time (low/medium vacuum) 4 5 1 2 3 4 1 2 3 The time (gt) required to exhaust a chamber at low vacuum with volume V (l), from pressure P1 to P2, using a pump with pumping speed S (l/sec) is gt=2.3(V/S)log(P1/P2).

When P1 is blinking, use UP & DOWN key to reconfirm each and individual present value. When the input, value is blinking, press READ once to shift the operation back to P1. 48 11-2 Program Setting Input desired cylinder positions. 11-2-1 Input Method Turn the controller switching mode to PROGRAM. Note: Step 0 for every program is END. Program no 1 will start blinking.

= 0.7 MPa, P2 = 0.5 MPa Effective area at supply side (mm2) S at P1 = 0.7 MPa, P2 = 0.5 MPa Note 3) 5.1 1.9 PA 5.8 2.1 PB Note 3) 12.6 4.5 AEA 12.6 4.5 BEB 1-5-80

How to Calculate Flow (At an air temperature 20C) 1P1+0.1013<1.89(P2+0.1013) Q=226S P(P2+0.1013) Piping 2P1+0.10131.89(P2+0.1013) 1Completely flush (air blow) pipes before plumbing to remove dust. 2Clamping torgue: Q=113S(P1+0.1013) Q:Flow rate under standard conditions [ /min (ANR)] P1:Upstream pressure (MPa) P2:Downstream pressure(MPa) P:Pressure differential(P1-P2)(MPa) S:Effective area

(P1 P2) : Upstream pressure (MPa) : Downstream pressure (MPa) : Effective area (mm) : Cv factor Q P P1 P2 S Cv 9

(P1 P2) : Upstream pressure (MPa) : Downstream pressure (MPa) : Effective area (mm) : Cv factor Q P P1 P2 S Cv 9 10 Series VCW Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.

How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 + 0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q: Air flow rate [l/min (ANR)] S: Effective area (mm) P: Differential pressure (P1-P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Correction for different air temperatures

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: J1 (Supply: NC, Release: None), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S.), Air Pressure

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: J1 (Supply: NC, Release: None), Pilot Valve: Y (DC Low Wattage Type (0.5W), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S.