(mm) <M5> <M5> Note) Weight (g) Model D1 P A M D2 L 2-applicable tubing M5 x 0.8 KJU23-M5 KJU23-01S KJU04-M5 KJU04-01S KJU06-M5 KJU06-01S 5.9 8.3 6.4 8.8 7.4 9.9 Reference dimensions after R thread installation.
P1=0.5MPa =0.5MPa P1=0.5MPa =0.5MPa P1=0.4MPa P1=0.5MPa P1=0.5MPa 0.4 P1=0.4MPa =0.4MPa VBA2 VBA2 VBA4 VBA4 VBA2 VBA4 AV 0.3 P1=0.3MPa =0.3MPa P1=0.4MPa =0.4MPa P1=0.3MPa =0.3MPa P1=0.3MPa P1=0.4MPa P1=0.3MPa 0.2 AU 0.1 AF 0 200 400 600 800 1000 1200 1400 1600 1800 2000 Outlet air flow (l/min (AMR)) Outlet air flow (l/min (AMR)) Outlet air flow (l/min (ANR)) Pressure Characteristics Inlet
= 1 MPa P1 = 0.8 MPa P1 = 0.6 MPa 30 30 Example 2 20 20 P1 = 0.5 MPa P1 = 0.4 MPa Example 1 10 10 P1 = 0.3 MPa P1 = 0.2 MPa 4 5 5 4 P1 = 0.1 MPa 3 3 2 2 1 1 0.001 0.01 0.1 0.002 0.003 0.02 0.03 0.04 0.004 Pressure differential P [MPa] Graph (2) Flow rate characteristics Example 1) Obtain the pressure difference when water [15 L/min] runs through the solenoid valve with a Kv = 1.5 m3/h.
P.T. 1 (P) 3 (R) (A) 10.5 30 (L) With miniature indicator Pneumatic indicator 10 12 17 44 25.4 2 x 4.6 mounting hole 19.5 8.5 14 2 x M5 x 0.8 depth 4 * 0.5 MPa supply Model L A VM122-M5-00A 32.5 7.5 F .O.F .* 26 N VM132-M5-00A P .T. 1.5 mm VM123-M5-00A 28.5 3.5 O.T. 1.5 mm VM133-M5-00A T.T. 3 mm Roller lever VM123-M5-01A VM133-M5-01A VM123-M5-01SA VM133-M5-01SA 10 Polyacetal or hard steel
How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 + 0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q: Air flow rate [l/min (ANR)] S: Effective area (mm) P: Differential pressure (P1P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Correction for different air temperatures
How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 + 0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q: Air flow rate [l/min (ANR)] S: Effective area [mm] P: Pressure drop rate (P1P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Correction for different air temperatures
. -4VEX-OMO0001 3 0 VEX1 3 Series / / / / / / / / ( ( ( ( ) ) ) ) -5VEX-OMO0001 3 VEX1 3 Series 0 ON-OFF (AF ) (AMAFM ) (P.2.3) [1 P][1P] PE ( ( ( ( ) ) ) ) IR2000 VEX 33 ITV VY 11 (0.5MPa ) (0.1MPa ), 2 Nm 1/6 MPa MPa MPa MPa MPa MPa MPa MPa MPa MPa MPa MPa MPa MPa MPa MPa -6VEX-OMO0001 3 VEX1 3 Series 0 +0.1MPa 2 PE(ASN2-M5) 0.1MPa P1 O M5 P1 O VEX1-A30-3 O P1 P1 P1
kPa PRESSURE kPa PRESSURE kPa PRESSURE kPa PRESSURE kPa PRESSURE OUT OUT OUT OUT OUT SET SET SET SET SET With One-touch fitting (4, 6, 5/32", 1/4") Reduced dimensions in piping direction 17.8 mm reduction Straight type 12.4 mm reduction Elbow type 14.4 22.4 12.4 mm 17.8 mm 32.2 34.8 KQ2H06-M5 KQ2L06-M5 Comparison when One-touch fittings (KQ2H06-M5 / KQ2L06-M5) are connected to the piping
RB RZQ Mounting Bolt J C CR D 110 135 160 120 145 170 130 155 180 135 160 185 CH Model RZQB32-25RZQB32-50RZQB32-75RZQB40-25RZQB40-50RZQB40-75RZQB50-25RZQB50-50RZQB50-75RZQB63-25RZQB63-50RZQB63-75Mounting bolt M5 x 110l M5 x 135l M5 x 160l M5 x 120l M5 x 145l M5 x 170l M6 x 130l M6 x 155l M6 x 180l M8 x 135l M8 x 160l M8 x 185l D9.5 8 -X 10 8.5 20Data 16.5 11.5 3 17.5 12.5 3.5 10-10-5 6
RZQ mounting bolt C CR D 110 135 160 120 145 170 130 155 180 135 160 185 CH Model RZQB32-25RZQB32-50RZQB32-75RZQB40-25RZQB40-50RZQB40-75RZQB50-25RZQB50-50RZQB50-75RZQB63-25RZQB63-50RZQB63-75Mounting bolt M5 x 110l M5 x 135l M5 x 160l M5 x 120l M5 x 145l M5 x 170l M6 x 130l M6 x 155l M6 x 180l M8 x 135l M8 x 160l M8 x 185l 9.5 8 10 8.5 16.5 11.5 3 17.5 12.5 3.5 4 Series RZQ Model Selection
Both of these become slower as the operating pressure is increased. 14 Technical Data 5 He leakage 8 Exhaust time (low/medium vacuum) The time (t) required to exhaust a chamber at low vacuum with volume V (l), from pressure P1 to P2, using a pump with pumping speed S (l/sec) is t=2.3(V/S)log(P1/P2).
Ported 10 10 Series VQZ1000/2000/3000 Dimensions: VQZ1000 2 position double Grommet (G): VQZ1220 1-G-C3/C4/C6/M5 300 95 (Lead wire length) 47.5 5.5 (M5: 6) 5.5 (M5: 6) 22.2 mounting hole 0.8 4 8.6 10 SMC SMC 2 R2 Cover diameter 1.6 25.8 2-C3, C4, C6, M5 Cross section 0.34 mm2 60.3 C3: One-touch fitting for 3.2 Manual override C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5
OFF OFF OFF OFF P1 n1 P2 P1 n2 n1 (Standard: Factory setting) (Reversed) (Standard: Factory setting) (Reversed) Press the SET button to set the mode and proceed to the output type setting. 3 2-Color Display Type High-Precision Digital Pressure Switch Series ZSE30/ISE30 Pressure setting Auto preset setting Manual setting Press the SET button in the measuring mode to display the set value.
Individual air supply port PV Individual air supply port PV Adapter D Adapter D M5 (or M6) Pitch = 21 Individual air supply port (PV port) M5 (or M6) Individual air supply port (PV port) Pitch = 21 M5 x 0.8 (or M6) Vacuum pad connection port (V port) (or M6) Vacuum pad connection port (V port) M5 x 0.8 M5 x 0.8 (or M6) Adsorption nozzle piping port 13-2-35 35 Series ZX Vacuum pad connection
Note 4) M5 fittings for M5 thread are attached without being incorporated.
Note 4) M5 fittings for M5 thread are attached without being incorporated.
2-Color Display Type High-Precision Digital Pressure Switch Series ZSE30/ISE30 How to Order Option 1 Without lead wire Nil Lead wire with connector (Lead wire length: 2m) L ISE30 01 25 M For positive pressure ZSE30 01 25 M For vacuum/Low pressure Option 2 Piping specification R 1/8 (with M5 female thread) NPT 1/8 (with M5 female thread) 01 T1 None Bracket Nil A Output specification NPN output
One of the preset pressures P1 through P4 is selected by the ON/OFF combination of S1 and S2.
VHS P1 P1 within 0.5 s P2 Output Output stops if either of the inputs are applied or neither are applied.
How to Find the Flow Rate (at air temperature of 20C) Choke flow: when (P2 + 0.1)/(P1 + 0.1) 0.5 293 273 + t Q = 120 x S x (P1 + 0.1) x Subsonic flow: when (P2 + 0.1)/(P1 + 0.1) > 0.5 Q = 240 x S x (P1 P2)(P2 + 0.1) x 293 273 + t Q : Air flow rate [l/min (ANR)] S : Effective area (mm) P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] t : Air temperature Note) Formulas above apply