Maintenance Bracket A or D(Model: ZS-24-A/ZS-24-D) Bracket B (Model: ZS-24-B) [01/N01 type] [W1/WF1 type] Operator How to reset the product after power cut or forcible de-energizing The setting of the product will be retained as it was before a power cut or de-energizing.
E L 4-H Valve mounting hole F Bracket Mounting Dimensions/Bracket Material: Stainless Steel (mm) A B C D E F G H J L Valve model Bracket part no.
Output Output 3 B Output 1 Output 2 A B C A B A Dimensions (mm) 1in = 25.4mm 1g = 0.0353 oz D3 Metric sizes: Light gray Inch sizes: Orange D2 L5 M2 IN Blue L3 L2 L4 OUT IN D1 M1 Applicable tubing O.D. d M1 L1 Metric sizes: Light gray Inch sizes: Orange Metric sizes Weight g Model d D1 D2 L3 L2 D3 L1 L4 L5 M1 M2 VR1210F-23 3.2 11.4 8.4 52 6.2 19.4 29.8 17.5 12.7 12.9 21.4 VR1210F-04 4 12.8
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, TIE ROD, LOCKING, ACTUATOR, CLA/CLA2 TIE-ROD CYLINDER, SE, 100MM CLA DBL-ACT AUTO-SW, 40.91779 lb
Option Applicable model 10-/21-AF20-A 10-/21-AF30-A 10-/21-AF40-A 10-/21-AF40-06-A 10-/21-AF50-A 10-/21-AF60-A Bracket assembly Note 2) AF52P-050AS AF22P-050AS AF32P-050AS AF42P-050AS AF42P-070AS Note 2) Assembly includes a bracket and 2 mounting screws. 1069-1 A Air Filter 1021-AF-A Dimensions AF20-A AF30-A to 40-06-A 10211021T N S J M U D J M U D S N T Air Preparation Equipment Pressure
Table 3-6 RTU mode message frame a) Start b) Device Address c) Function d) Data e) Checksum (CRC) f) End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (non-communication time).
(Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 1000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature.
The signal has to be converted by a A/D converter for pressure display or switch output. Current Output signal is a current signal in the range of 4 to 20[mA]. The signal is transformed into a voltage signal before being converted by a A/D converter for pressure display or switch output.
set position. 2 wiring methods Centralized Wiring Individual wiring Minimum operating pressure 30 kPa (ISA2-G) Energy consumption can be reduced compared with the conventional models (Conventional models: 50 kPa) Position of supply port: Either right side or left side is available. 865 A Air Catch Sensor Series ISA2 How to Order Manifold IISA2 N 3 B PL Without control unit SL C 3 B 1 E2 D
C E E (KF ) Fn J H B A G A mm A B C D E Fn G H J XLC-16 40 110 38 1 30 17 40 26 XLC-25 50 120 48 1 12 40 26 39 27.5 XLC-40 65 171 66 2 11 55 41 63 36 9 XL-OMV0002 4-2.162580,100,160 C E D C E E (KF ) (K ) Fn Fd J K H B A G A mm A B C D E Fn Fd G H J K XLC-50 70 183 80 31 10.5 75 52 77 29 10.5 XLC-63 88 209 100 39 11 87 95 70 76.5 36 9 XLC-80 90 250 117 45.5 11 114 110 83 105 44 9 XLC-100
(Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 1000 Hz. Test was performed at both energized and deenergized states in the axial direction and at the right angles to the main valve and armature.
Note 3) Bowl assembly for AL30 to AL60 comes with a bowl guard (steel band material). 52 AL10 to 60 Dimensions AL10 AL20 L D Bracket (option) G F Port size K M A Port size C B R C J H OUT OUT IN OUT OUT IN B R P Min. clearance for maintenance Min. clearance for maintenance A AL50, 60 AL30, 40 L D D L Port size Bracket (option) Bracket (option) G F G F Port size M K M K E J C B R C B R H
Auto switch Auto Switch Specifications D-M9P (With indicator light) Auto switch model D-M9P Electrical entry direction In-line Wiring 3-wire Output PNP type Applicable load IC circuit,Relay,PLC Power supply voltage DC51224V(4.5 to 28V) Current consumption 10 mA or less Load voltage DC28V or less Load current 40 mA or less Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA)
E F C (35.4[900]) J M N P L K H 4x0..5 (0.4[9~11mm] [4x13] [IDFB22E-11*(L=2800)] Unitinch [mm] A B C D E F G H J K L M N P 30.5 23.6 IDFB22E 1 [775] [600] 3.3 11.4 24.5 5.3 15.9 27.5 3.7 1.8 1 0.5 12.4 13.4 [290] [623] [134] [405] [698] [93] [46] [25] [13] [314] [85] [340] 26.8 33.7 IDFB37E 1/2 [855] [680] R IDFB55E/75E Q A B H G E D F C (0.4 (39.4[1000]) J L K M N P 4x0..5 [4x13]
Enclosure Centralized wiring Centralized wiring 16-8-3 4 Air Catch Sensor Series ISA2 How to Order Manifold IISA2 N 3 B PL Without control unit IISA2 SL C 3 B 1 D E2 With control unit Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Pressure gauge of regulator Note
Dimensions Meter-out type Meter-in type F E D B A C J G K H L B Model A MIN. MAX. MIN. MAX.
S1, S2: Fixed orifice S3: Variable orifice (adjusted by setting dial) S4: Detection nozzle S1: Fixed orifice S2: Detection nozzle Measures against clogging Measures against clogging D C Number of orifices Orifice area ratio 3 1 68% increase1 By reducing the number of internal orifices from 3 A larger orifice area provides less possibility of to 1, there is less possibility of variations