SMC Corporation of America
Elite Part Number Search
Search Results "LECP1P1-LEFB16T-600"

Parallel I/O Type: P (PNP), I/O Cable Length, m: 3, Option: Screw Mounting, Actuator: LEFB (Belt Drive), Accuracy: Basic, Size Motor Mounting and Lead: 16T (Size 16, 48mm Lead), Stroke: 500mm

Parallel I/O Type: N (NPN), I/O Cable Length, m: 5, Option: Screw Mounting, Actuator: LEFB (Belt Drive), Accuracy: Basic, Size Motor Mounting and Lead: 16T (Size 16, 48mm Lead), Stroke: 300mm

Parallel I/O Type: P (PNP), I/O Cable Length, m: 5, Option: Screw Mounting, Actuator: LEFB (Belt Drive), Accuracy: Basic, Size Motor Mounting and Lead: 16T (Size 16, 48mm Lead), Stroke: 1000mm

Parallel I/O Type: N (NPN), I/O Cable Length, m: 1 (1.5), Option: Screw Mounting, Actuator: LEFB (Belt Drive), Accuracy: Basic, Size Motor Mounting and Lead: 16T (Size 16, 48mm Lead), Stroke: 300mm

Parallel I/O Type: P (PNP), I/O Cable Length, m: 3, Option: D (DIN Rail Mounting), Actuator: LEFB (Belt Drive), Accuracy: Basic, Size Motor Mounting and Lead: 16T (Size 16, 48mm Lead), Stroke: 700mm

Parallel I/O Type: P (PNP), I/O Cable Length, m: 3, Option: D (DIN Rail Mounting), Actuator: LEFB (Belt Drive), Accuracy: Basic, Size Motor Mounting and Lead: 16T (Size 16, 48mm Lead), Stroke: 300mm

Parallel I/O Type: P (PNP), I/O Cable Length, m: 3, Option: D (DIN Rail Mounting), Actuator: LEFB (Belt Drive), Accuracy: Basic, Size Motor Mounting and Lead: 16T (Size 16, 48mm Lead), Stroke: 500mm

Series: LEFB (Belt Drive), Size: 16, Motor: Step Motor (Servo 24 VDC), Lead: T, Stroke: 300mm, Motor Option: w/o Lock, Auto Switch Mounting Bracket: None, Grease Application: With, Positioning Pin Hole: Housing B (Bottom), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: C61 (JXC61, Parallel PNP, Step Data Input Type), I/O Cable Length for LEC

Series LECP6 controller has two available modes for the setting software and teaching box.  In the easy mode, the operation can be started by only setting the speed, position, etc.  Using the normal mode allows a further detailed setup.  A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator

LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box.  Through the combination of parallel I/O inputs, 14 points of positioning are available.  The speed and acceleration of the positioning can be set by the switch for each operating direction.  A single signal sent to a dedicated terminal returns an actuator to

Parallel I/O Type: PNP, I/O Cable Length: w/o Cable, Mounting: Screw Mounting, Actuator: Belt Drive, Type: Basic Type, Size: 16, Lead: 48mm, Stroke: 500mm

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

460 600 450 Dimensions inside ( ) are for a 100 mm stroke.

460 600 450 Dimensions inside ( ) are for a 100 mm stroke.

mm] 600 600 600 600 Me X 400 400 400 400 m 200 200 200 200 0 0 0 0 0 10 20 30 50 40 0 20 40 60 80 0 10 5 15 20 0 10 5 15 20 30 25 Work load [kg] Work load [kg] Work load [kg] Work load [kg] 1000 1000 1000 1000 800 800 800 800 Me L5 [mm] L5 [mm] L5 [mm] L5 [mm] m 600 600 600 600 L5 Wall Y 400 400 400 400 200 200 200 200 0 0 0 0 0 10 20 30 50 40 0 20 40 60 80 0 10 5 15 20 0 10 5 15 20 30 25

A B C D Maximum Speeds for Each Transfer Load Unit (mm/s) Transfer load (kg) 15 20 25 30 1000 1000 930 740 600 500 Note Model LJ1H202PC-500LJ1H202PC-600LJ1H202PC-700LJ1H202PC-800LJ1H202PC-900LJ1H202PC-1000700 700 600 600 500 500 500 500 500 500 500 500 500 500 500 500 500 500 Power supply: 100/110(V)AC 10% Compatible controller: LC1-1B2H1Power supply: 200/220(V)AC 10% Compatible controller

, 700, 800 900, 1000, 1200 300, 400, 500, 600, 700, 800, 900 1000, 1200, 1500 LEF Work load [kg] Note 2) Horizontal 15 30 55 30 45 85 Vertical 3 5 10 6 10 20 LEJ Up to 500 1800 1200 600 1800 1200 600 501 to 600 1580 1050 520 1800 1200 600 601 to 700 1170 780 390 1800 1200 600 701 to 800 910 600 300 1390 930 460 801 to 900 720 480 240 1110 740 370 901 to 1000 580 390 190 900 600 300 1001 to

Specifications Model LEJS40 LEJS63 Stroke [mm] Note 1) 200, 300, 400, 500, 600, 700, 800 900, 1000, 1200 300, 400, 500, 600, 700, 800, 900 1000, 1200, 1500 Work load [kg] Note 2) Horizontal 15 30 55 30 45 85 LEF Vertical 3 5 10 6 10 20 Up to 500 1800 1200 600 LEJ 1800 1200 600 501 to 600 1580 1050 520 601 to 700 1170 780 390 LEL 701 to 800 910 600 300 1390 930 460 801 to 900 720 480 240 1110

300 400 500 600 700 800 900 0 200 400 600 800 1000 1200 Speed: V [mm/s] Speed: V [mm/s] Servo Motor (24 VDC) The following graph shows the values when moving force is 250%.

Wall Note) For air-cooled type, leave a space of at least 600 mm between the heat exhausting surface and the wall. For water-cooled type, leave a space at least 600 mm between the facility water piping side and the wall. Leave at least 600 mm on the sides indicated with .